• Title/Summary/Keyword: Aerosol concentration

Search Result 513, Processing Time 0.023 seconds

Composition and pollution characteristics of TSP, PM2.5 atmospheric aerosols at Gosan site, Jeju Island (제주도 고산지역 TSP, PM2.5 대기에어로졸의 조성 및 오염 특성)

  • Lee, Soon-Bong;Kang, Chang-Hee;Jung, Duk-Sang;Ko, Hee-Jung;Kim, Haeng-Bum;Oh, Yong-Soo;Kang, Hae-Lim
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.371-382
    • /
    • 2010
  • TSP and PM2.5 atmospheric aerosols have been collected at Gosan site of Jeju Island, and their compositions were analyzed to understand the pollution characteristics. The composition ratios of nss (non-sea salt)-$SO_4^{2-}$ and $NH_4^+$ were higher in Gosan site than those in other Korean background and urban sites. However the composition ratio of $NO_3^-$ was conversely lower in Gosan site. From the study of aerosol components according to particle sizes, the anthropogenic nss-$SO_4^{2-}$, $NO_3^-$ and $NH_4^+$ components were mostly existed in the fine particles. But the nss-$Ca^{2+}$, $Na^+$, $Cl^-$ and $Mg^{2+}$ originated from soil and marine sources were distributed relatively in the coarse particles. In the seasonal comparison, the concentrations of nss-$Ca^{2+}$, Al, Fe, Ca and $NO_3^-$ increased in spring season, and nss-$SO_4^{2-}$ showed higher concentration in summer and spring seasons. Based on the factor analysis, the atmospheric aerosols in Gosan site have been found to be influenced largely by anthropogenic sources, and next by marine and soil sources. The backward trajectory analyses showed that the concentrations of nss-$SO_4^{2-}$, $NO_3^-$, Pb and nss-$Ca^{2+}$ increased when the air mass moved from Chinese continent to Jeju area. On the other hand, their concentrations decreased when the air mass moved in from the North Pacific Ocean.

A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement (PM10 질량농도 측정을 위한 시료채취기의 비교 연구)

  • Park, Ju-Myon;Koo, Ja-Kon;Jeong, Tae-Young;Kwon, Dong-Myung;Yoo, Jong-Ik;Seo, Yong-Chil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A PM10 (aerodynamic diameter${\leq}$10 ${\mu}m$) sampler is used to quantify the potential human exposure to suspended particulate matter (PM) and to comply with the governmental regulation. This study was conducted to compare and evaluate the same PM10 cutpoint and different slopes between United States Environmental Protection Agency (USEPA) PM10 sampling criterion and American Conference of Governmental Industrial Hygienists/$Comit\acute{e}$ $Europ\acute{e}en$ de Normalization/International Organization for Standardization thoracic PM10 sampling criterion through theory and experiment. Four PM10 samplers according to the USEPA criterion and one RespiCon sampler in accordance with the thoracic PM10 criterion were used in the present study. In addition, one DustTrak monitor was used to measure real time PM10 mass concentrations. All six aerosol samplers were tested in a PM generation chamber using polydisperse fly ash. Theoretical mass concentrations were calculated by applying the measured particle size distribution characteristics (geometric mean = 6.6 ${\mu}m$, geometric standard deviation = 1.9) of fly ash to each sampling criterion. The measured mass concentrations through a chamber experiment were consistent with theoretical mass concentrations in that a RespiCon sampler with the thoracic PM10 criterion collected less PM than a PM10 sampler with the USEPA criterion. The overall chamber experiment results indicated, when a PM10 sampler was used as a reference sampler, that (1) a RespiCon sampler had a normalizing factor of 1.6, meaning that this sampler underestimated an average 60% of PM10 mass sampled from a PM10 sampler, and (2) a DustTrak real-time monitor using a PM10 inlet had a calibration factor of 2.1.

A Study on the Smog Reduction Strategies in China (중국의 스모그 저감정책에 대한 고찰)

  • Jeon, So Hyeon;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.11 no.3
    • /
    • pp.63-75
    • /
    • 2015
  • Atmospheric environment in Korea is influenced by outside, especially China. The concentrations of air pollutants in China have showed decreasing trends since 2000. However, these concentration levels in China are still higher than other developed countries. The Chinese Government has tried several measures to control the air pollution. In this study, the details of the amendments and smog reduction strategies in China, especially for Beijing are reviewed and the strategies for Korean side to promote cooperation in Northeast Asia are suggested and discussed. The Chinese State Council amended the Environmental Protection Provisions and Clean Air Act and announced The Action Plan for Air Pollution Control (2013-2017), focusing on three key regions, Beijing-Tianjin-Hebei area (Jing-Jin-Ji), Yangtze River Delta (YRD) and Pearl River Delta (PRD). These policy actions and plan are mainly for the reducing coal usage and emissions from vehicles. It is suggested that, Korea should actively promote multi-national cooperation in the region to take an initiative role in environmental areas.

Comparison of PM1, PM2.5, PM10 Concentrations in a Mountainous Coastal City, Gangneung Before and After the Yellow Dust Event in Spring (봄철 황사 전후 산악연안도시, 강릉시에서 PM1, PM2.5, PM10의 농도비교)

  • Choi, Hyo
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.633-645
    • /
    • 2008
  • In order to investigate the variations and corelation among $PM_{10},\;PM_{2.5}\;and\;PM_1$ concentrations, the hourly concentrations of each particle sizes of 300nm to $20{\mu}m$ at a city, Gangneung in the eastern mountainous coast of Korean peninsula have been measured by GRIMM aerosol sampler-1107 from March 7 to 17, 2004. Before the influence of the Yellow Dust event from China toward the city, $PM_{10},\;PM_{2.5}\;and\;PM_1$, concentrations near the ground of the city were very low less than $35.97{\mu}g/m^3,\;22.33{\mu}g/m^3\;and\;16.77{\mu}g/m^3$, with little variations. Under the partial influence of the dust transport from the China on March 9, they increased to $87.08{\mu}g/m^3,\;56.55{\mu}g/m^3\;and\;51.62{\mu}g/m^3$. $PM_{10}$ concentration was 1.5 times higher than $PM_{2.5}$ and 1.85 times higher than $PM_1$. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 1.49 with an averaged 0.5 and one of $(PM_{2.5}-PM_1)/PM_1$ had a maximum value of 0.4 with an averaged 0.25. $PM_{10}\;and\;PM_{2.5}$ concentrations were largely influenced by particles smaller than $2.5{\mu}m\;and\;1{\mu}m$ particle sizes, respectively. During the dust event from the afternoon of March 10 until 1200 LST, March 14, $PM_{10},\;PM_{2.5}\;and\;PM_1$ concentrations reached $343.53{\mu}g/m^3,\;105{\mu}g/m^3\;and\;60{\mu}g/m^3$, indicating the $PM_{10}$ concentration being 3.3 times higher than $PM_{2.5}$ and 5.97 times higher than $PM_1$. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 7.82 with an averaged 3.5 and one of $(PM_{2.5}-PM_1)/PM_1$, had a maximum value of 2.8 with an averaged 1.5, showing $PM_{10}\;and\;PM_{2.5}$ concentrations largely influenced by particles greater than $2.5{\mu}m\;and\;1{\mu}m$ particle sizes, respectively. After the dust event, the most of PM concentrations became below $100{\mu}g/m^3$, except of 0900LST, March 15, showing the gradual decrease of their concentrations. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 3.75 with an averaged 1.6 and one of $(PM_{2.5}-PM_1)/PM_1$ had a maximum value of 1.5 with an averaged 0.8, showing the $PM_{10}$ concentration largely influenced by corse particles than $2.5{\mu}m$ and the $PM_{2.5}$ by fine particles smaller than $1{\mu}m$, respectively. Before the dust event, correlation coefficients between $PM_{10},\;PM_{2.5}\;and\;PM_1$, were 0.89, 0.99 and 0.82, respectively, and during the dust event, the coefficients were 0.71, 0.94 and 0.44. After the dust event, the coefficients were 0.90, 0.99 and 0.85. For whole period, the coefficients were 0.54, 0.95 and 0.28, respectively.

Effect of Short Term Treatment with Different Dosage of Inhaled Flucatisone Propionate on Basal Cortisol Concentration (단기간 Fluticasone Propionate 투여 용량에 따른 가저 코르티솔 농도의 변화)

  • Kim, Hyun-Jung;Kim, Hyoung-Sik;Lee, Hong;Moon, Sung-Gi;Lim, Seok-Tae;Park, Ji-Hyun;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1063-1071
    • /
    • 1997
  • Backgroung : The efficacy of oral corticosteroids in the treatment of chronic asthma is undisputed, but their long-term use is associated with adverse side-effects, including supression of the hypothalamic-pituitary adrenal axis function, osteoporosis, weight gain, hypertension and impaired glucose tolerance. The introduction of inhaled corticosteroids in the early 1970's represented a significant therapeutic advance in the management of asthma, since these compounds combined high topical potency with low systemic activity. Fluticasone propionate is a new topically active synthetic glucocorticosteroid that combinds a high degree of efficacy with negligible systemic bioavailability. This study was perfomed to determine the effect of inhaled fluticasone propionate on the adreocortical supression in patients with bronchial asthma or chronic obstructive pulmonary disease. Method : The adrenocortical function was assessed by measurement of plasma cortisol concentration at 8 o'clock in morning and free cortisol in 24 hour urine collection at interval. Absolutely, no steroid was taken during pretreatment period of 10days. There after each subject inhaled fluticasone aerosol, in daily doses of 500 or 1000micrograms for 12days. The dose was delivered by metered dose inhaler(MDI). Results : The serum cortisol and 24hour urinary free cortisol were not decreased during the treatment period in patients with inhaled fluticasone propionate in daily doses of 500 micrograms. In contrast, serum cortisol was significantly decreased on 9th and 12th day(p less than 0.05). And, 24hour urinary free cortisol was also significantly decreased on 3rd and 12th day of treatement period(p less than 0.05) in patients with inhaled fluticasone in daily doses of 1000 micrograms. Conclusion : These results suggested that endogenous cortisol secretion was not supressed after short-term inhalation of fluticasone in daily dose of 500 micrograms, but in daily dose of 1000 micrograms, the endogenous cortisol secretion was supressed.

  • PDF

The Study on the Emission Characteristics of Particulate Matters from Meat Cooking (고기구이에서 발생하는 입자상물질의 배출특성에 관한 연구)

  • Bong, C.K.;Park, S.J.;Park, S.K.;Kim, J.H.;Hwang, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.196-201
    • /
    • 2011
  • Emission from meat cooking may contribute to the concentration of the Particulate Matters(PM) in the city. This study is to investigate the particle size and the emission characteristics of particulate matters from pork and beef cooking. The chamber was installed for sampling of PM generated from pork belly and beef sirloin cooking including seasoned ones. Cascade Impactor and Portable Aerosol Monitor (PAM) were used to analyse the particle size distribution. At the result of the Cascade Impactor sampling, particulate matters from the pork cooking was higher than that of beef. The gravimetric concentration of PM according to the size was highest at the range of $1.95{\sim}3.2{\mu}m$ and the gravimetric concentration of PM from the non-seasoned meat was higher than that of the seasoned one. The emission factors from pork, pork seasoned, beef and beef seasoned were 1.36 g/kg, 1.03 g/kg, 1.23 g/kg, 0.92 g/kg respectively. To see the result of PAM sampling, the ranges of $1.6{\sim}2.5{\mu}m$ and $2.5{\sim}3.5{\mu}m$ were reveled as highest. The ration of $PM_{2.5}/PM_{10}$ from pork and beef was 0.56~0.58. The emission factors from pork, pork seasoned, beef and beef seasoned measured by PAM were revealed as 3.37 g/kg, 2.76 g/kg, 2.93 g/kg, 2.77 g/kg respectively.

Analysis of Uncertainty in Ocean Color Products by Water Vapor Vertical Profile (수증기 연직 분포에 의한 GOCI-II 해색 산출물 오차 분석)

  • Kyeong-Sang Lee;Sujung Bae;Eunkyung Lee;Jae-Hyun Ahn
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1591-1604
    • /
    • 2023
  • In ocean color remote sensing, atmospheric correction is a vital process for ensuring the accuracy and reliability of ocean color products. Furthermore, in recent years, the remote sensing community has intensified its requirements for understanding errors in satellite data. Accordingly, research is currently addressing errors in remote sensing reflectance (Rrs) resulting from inaccuracies in meteorological variables (total ozone, pressure, wind field, and total precipitable water) used as auxiliary data for atmospheric correction. However, there has been no investigation into the error in Rrs caused by the variability of the water vapor profile, despite it being a recognized error source. In this study, we used the Second Simulation of a Satellite Signal Vector version 2.1 simulation to compute errors in water vapor transmittance arising from variations in the water vapor profile within the GOCI-II observation area. Subsequently, we conducted an analysis of the associated errors in ocean color products. The observed water vapor profile not only exhibited a complex shape but also showed significant variations near the surface, leading to differences of up to 0.007 compared to the US standard 62 water vapor profile used in the GOCI-II atmospheric correction. The resulting variation in water vapor transmittance led to a difference in aerosol reflectance estimation, consequently introducing errors in Rrs across all GOCI-II bands. However, the error of Rrs in the 412-555 nm due to the difference in the water vapor profile band was found to be below 2%, which is lower than the required accuracy. Also, similar errors were shown in other ocean color products such as chlorophyll-a concentration, colored dissolved organic matter, and total suspended matter concentration. The results of this study indicate that the variability in water vapor profiles has minimal impact on the accuracy of atmospheric correction and ocean color products. Therefore, improving the accuracy of the input data related to the water vapor column concentration is even more critical for enhancing the accuracy of ocean color products in terms of water vapor absorption correction.

An Analysis of Aerosol Mass Concentrations and Elemental Constituents Measured at Cheongwon depending on the Backward Trajectories of Air Parcel in East Asia in 2011 (2011년 동아시아에서 기류의 이동 경로에 따른 청원에서 측정한 에어로졸 질량 농도 및 원소 성분 분석)

  • Kim, Hak-Sung;Byun, Kwang-Tae;Chung, Yong-Seung;Choi, Hyun-Jung;Kim, Min-Jung
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.855-863
    • /
    • 2012
  • This study analyzed mass concentrations of TSP, PM10 and PM2.5 and elemental constituents according to the isentropic backward trajectories of air parcel from Cheongwonin East Asia during the period January - October, 2011. Mass concentrations of the continental polluted airflow (CP) showed levels of TSP and PM10 mass concentrations higher than the continental background airflow (CB). Also, PM2.5 mass concentrations of anthropogenic fine particles ran higher in CP than in CB. The elemental constituents and elemental constituent ratio ended up varying depending on the origin of atmospheric aerosols generated. The average absolute content of elemental constituents reached its height in CB, the ratio of anthropogenically originating elements (PE) among the all elements (AE) analyzed marked a high in CP, and Mg+Na/AE reached its height in the oceanic airflow (OA). At the same time, TSP, PM10 and PM2.5 mass concentrations, the ratio of PM2.5/TSP and PE/AE element ratio ran higher in CP than CB. Episodes of large-scale transport of atmospheric pollutants as observed at Cheongwon were 8 cases and 22 days. The ratios of PM10, PM2.5 among TSP mass concentrations showed different results and the ratios of PM2.5 showed an increasing trend in the episodes of anthropogenic air pollution transport. Overall, dustfall episodes show a level of elemental constituents higher than those of anthropogenic air pollution.Dustfall episodes were observed to contain more of Fe, Al and Ca originating from continental soils and those of air pollution were observed to contain more of Zn, Mn, Cu and Pb. By difference in contents of absolute elemental constituents, episodes of anthropogenic air pollution showed a high PE/AE rate, and dustfall episodes a high SE/AE rate.

Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements (대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교)

  • Jung, Jung-Hoon;Park, Seung-Shik;Yoon, Kwan-Hoon;Cho, Sung-Yong;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.

Turbid water atmospheric correction for GOCI: Modification of MUMM algorithm (GOCI영상의 탁한 해역 대기보정: MUMM 알고리즘 개선)

  • Lee, Boram;Ahn, Jae Hyun;Park, Young-Je;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.2
    • /
    • pp.173-182
    • /
    • 2013
  • The early Sea-viewing Wide Field-of-view Sensor(SeaWiFS) atmospheric correction algorithm which is the basis of the atmospheric correction algorithm for Geostationary Ocean Color Imager(GOCI) assumes that water-leaving radiances is negligible at near-infrared(NIR) wavelengths. For this reason, all of the satellite measured radiances at the NIR wavelengths are assigned to aerosol radiances. However that assumption would cause underestimation of water-leaving radiances if it were applied to turbid Case-2 waters. To overcome this problem, Management Unit of the North Sea Mathematical Models(MUMM) atmospheric correction algorithm has been developed for turbid waters. This MUMM algorithm introduces new parameter ${\alpha}$, representing the ratio of water-leaving reflectance at the NIR wavelengths. ${\alpha}$ is calculated by statistical method and is assumed to be constant throughout the study area. Using this algorithm, we can obtain comparatively accurate water-leaving radiances in the moderately turbid waters where the NIR water-leaving reflectance is less than approximately 0.01. However, this algorithm still underestimates the water-leaving radiances at the extremely turbid water since the ratio of water-leaving radiance at two NIR wavelengths, ${\alpha}$ is changed with concentration of suspended particles. In this study, we modified the MUMM algorithm to calculate appropriate value for ${\alpha}$ using an iterative technique. As a result, the accuracy of water-leaving reflectance has been significantly improved. Specifically, the results show that the Root Mean Square Error(RMSE) of the modified MUMM algorithm was 0.002 while that of the MUMM algorithm was 0.0048.