• Title/Summary/Keyword: Aerosol Process

Search Result 218, Processing Time 0.021 seconds

Development of a Miniature Aerosol Separator for a Black Carbon Measuring Instrument (블랙카본 측정기용 초소형 사이클론 집진기 개발)

  • An, Ik-Hyun;Lim, Jun-Hyung;Lee, Hyo-Young;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.42-48
    • /
    • 2020
  • Given the increasing interest in air pollution, several technologies to measure black carbon (BC) aerosol particles have been developed. As most BC aerosol particles are smaller than 1 ㎛, it is necessary to pre-separate the particles by size before a BC measuring instrument samples the aerosol particles. In this study, a miniature cyclone separator for portable BC measuring instruments was developed. A numerical approach was used to design the miniature cyclone separator with operating flow rates of 50, 100, or 150 mLPM, and then a prototype cyclone separator was manufactured for experimental validation. The numerical results of the cut-off size and pressure drop of the miniature cyclone separator agreed well with the experimental data. The cut-off sizes of the miniature cyclone separator were determined to be 2.9, 0.94, and 0.63 ㎛ for operating flow rates of 50, 100, and 150 mLPM, respectively. Thus, the miniature cyclone separator is suitable for use as a sampling inlet for the portable black carbon measuring instrument to sample BC aerosol or PM2.5 aerosol.

Nanoparticle generation and growth in low temperature plasma process (저온 플라즈마 공정에서의 나노 미립자 생성 및 성장)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Particle and aerosol research
    • /
    • v.5 no.3
    • /
    • pp.95-109
    • /
    • 2009
  • A low temperature plasma process has been widely used for semiconductor fabrication and can also be applied for the preparation of solar cell, MEMS or NEMS, but they are notorious in the point of particle contamination. The nano-sized particles can be generated in the low temperature plasma process and they can induce several serious defects on the performance and quality of microelectronic devices and also on the cost of final products. For the preparation of high quality thin films of high efficiency by the low temperature plasma process, it is desirable to increase the deposition rate of thin films with reducing the particle contamination in the plasmas. In this paper, we introduced the studies on the generation and growth of nanoparticles in the low temperature plasmas and tried to introduce the recent interesting studies on nanoparticle generation in the plasma reactors.

  • PDF

Experimental and Numerical Study of Aerosol Coagulation by Gravitation (에어로졸 입자의 중력응집에 관한 실험 및 수치적 연구)

  • 권순박;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • The behavior of aerosos due to gravitational coagulation was studied experimentally and numerically. In experimental study, the geometric mean particel size increased as time elapsed in a vertical tube column, while the size decreased when the tube was set horizontally. The particle size distribution was observed to maintain the lognormal form during the coagulation process. Separately, numerical calculations were performed for studying the aerosol behavior under gravitational and Brownian coagulation using the moment method. By comparing the expeimented results with the numerical predictions, the governing mechanism of the aerosol behavior proved to be gravitational coagulation.

  • PDF

Aerosol Generation Mechanism for Cutting Fluid in Turning (선삭에서 절삭유 미립화 생성 메카니즘)

  • 박성호;고태조;김희술
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.179-184
    • /
    • 2001
  • The mechanism of the aerosol generation consists of spin-off, splash, and evaporation/condensation. Most researchers showed some theoretical model for predicting the particulate size and generation rate without cutting in turning operation. These models were based on the spin-off mechanism and verified good for modeling the process. However, in real machining, the cutting tool destructs the spin-off process, and the majority of the mist is due to splash. In this paper, we show some experimental evidence the aerosol generation mechanism should be explained with splash model as well as spin-off.

  • PDF

Experimental Verification of Aerosol Generation Mechanism for Cutting Fluid in Turning (선삭에서 절삭유 미립화 생성 메카니즘의 실험적 검증)

  • 고태조;오명석;박성호;김희술
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.93-99
    • /
    • 2002
  • The mechanism of the aerosol generation generally consists of spin-off, splash, and evaporation/condensation. Most researchers showed some theoretical model for predicting the particulate size and generation rate without real cutting in turning operation. These models were based on the spin-off mechanism, and verified good for modeling the process. However, in real machining, the cutting tool destroys the spin-off process, and the majority of the mist is due to splash. In this paper, we show some experimental evidence that the aerosol generation mechanism in real machining should be explained with splash model as well as spin-off.

Aerosol Losses in a 100L $Tedlar^{(R)}$ Bag

  • Oh, Sewon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.61-68
    • /
    • 2004
  • Aerosol losses in a 100L Tedlar$^{(R)}$ bag were investigated for the aerosols with number median diameter of 0.05 ${\mu}{\textrm}{m}$ and number concentration of 6.4 ${\times}$ 10$^4$ cm$^{-3}$ . Over a 1 hr period, loss of particles in the bag is apparent, and the volume decrease with time is significant. The number concentration, surface area, and volume concentration of the aerosols decreased to 34, 50, and 52% of the initial value in 30 min, respectively. This indicates that deposition to the walls was the main loss process for aerosols in the Tedlar$^{(R)}$ bag. Theoretical calculations showed that coagulations and deposition by diffusion and gravitational sedimentation would not change aerosol characteristics significantly, and the electrical force was the dominant loss process for particles in the Tedlar$^{(R)}$ bag over a 1 hr period.eriod.

Changes in the Ångstrom Exponent during Aerosol Coagulation and Condensation

  • Jung, Chang H.;Lee, Ji Yi;Kim, Yong P.
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.304-313
    • /
    • 2012
  • In this study, the ${\AA}$ngstrom exponent for polydispersed aerosol during dynamic processes was investigated. Log-normal aerosol size distribution was assumed, and a sensitivity analysis of the ${\AA}$ngstrom exponent with regards the coagulation and condensation process was performed. The ${\AA}$ngstrom exponent is expected to decrease because of the particle growth due to coagulation and condensation. However, it is difficult to quantify the degree of change. In order to understand quantitatively the change in the ${\AA}$ngstrom exponent during coagulation and condensation, different real and imaginary parts of the refractive index were considered. The results show that the ${\AA}$ngstrom exponent is sensitive to changes in size distribution and refractive index. The total number concentration decreases and the geometric mean diameter of aerosols increase during coagulation. On the while, the geometric standard deviation approaches monodispersed size distribution during the condensation process, and this change in size distribution affects the ${\AA}$ngstrom exponent. The degree of change in the ${\AA}$ngstrom exponent depends on the refractive index and initial size distribution, and the size parameter changes with the ${\AA}$ngstrom exponent for a given refractive index or chemical composition; this indicates that the size distribution plays an important role in determining the ${\AA}$ngstrom exponent as well as the chemical composition. Subsequently, this study shows how the ${\AA}$ngstrom exponent changes quantitatively during the aerosol dynamics processes for a log-normal aerosol size distribution for different refractive indices; the results showed good agreement with the results for simple analytic size distribution solutions.

Prediction Model of Aerosol Generation for Cutting Fluid in Turning (선삭에서 절삭유 입자 발생 예측모델)

  • 박성호;오명석;고태조;김희술
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.69-76
    • /
    • 2004
  • This paper presents a prediction model for the aerosol generation of cutting fluid in turning process. Experimental studies have been carried out in order to identify the characteristics of aerosol generation in non-cutting and cutting cases. The indices of aerosol generation was mass concentration comparable to number generation, which is generally used fur environment criterion. Based on the experimental data, empirical model for predicting aerosol mass concentration of cutting fluid could be obtained by a statistical analysis. This relation shows good agreement with experimental data.

Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger (패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가)

  • Ji, Jun-Ho;Bae, Kwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Estimation and Validation of Collection 6 Moderate Resolution Imaging Spectroradiometer Aerosol Products for East Asia

  • Lee, Kwon-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.193-203
    • /
    • 2018
  • The operational aerosol retrieval algorithm for the Moderate Resolution Imaging Spectroradiometer (MODIS) measurements was recently updated and named collection 6 (C6). The C6 MODIS aerosol algorithm, a substantially improved version of the collection 5 (C5) algorithm, uses an enhanced aerosol optical thickness(AOT) retrieval process consisting of new surface reflection and aerosol models. This study reports on the estimation and validation of the two latest versions, the C5 and C6 MODIS aerosol products over the East Asian region covering $20^{\circ}N$ to $56^{\circ}N$ and $80^{\circ}E$ to $150^{\circ}E$. This study also presents a comparative validation of the two versions(C5 and C6) of algorithms with different methods(Dark Target(DT) and Deep Blue (DB) retrieval methods) from the Terra and Aqua platforms to make use of the Aerosol Robotic Network (AERONET) sites for the years 2000-2016. Over the study region, the spatially averaged annual mean AOT retrieved from C6 AOT is about 0.035 (5%) less than the C5 counterparts. The linear correlations between MODIS and AERONET AOT are R = 0.89 (slope = 0.86) for C5 and R = 0.95 (slope = 1.00) for C6. Moreover, the magnitude of the mean error in C6 AOT-the difference between MODIS AOT and AERONET AOT-is 40% less than that in C5 AOT.