• Title/Summary/Keyword: Aerosol Particle

Search Result 666, Processing Time 0.024 seconds

The growth of zinc oxide particles by coagulation in aerosol reactor (에어로졸 반응기에서 산화아연 입자의 응집 성장)

  • Lee, Jong Ho;Song, Shin Ae;Park, Seung Bin
    • Particle and aerosol research
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2008
  • Nanosize ZnO particles were prepared by oxidation of zinc vapor and the particle growth was modeled by a coagulation model by assuming that the characteristic time for reaction was much shorter than coagulation time and residence time (${\tau}_{reaction}{\ll}{\tau}_{coagulation}{\ll}{\tau}_{residence}$). Experimental measurement of zinc oxide particles diameter was consistent with the predicted result from the coagulation model. For practical purpose of predicting zinc oxide size in areosol reactor, the constant kernel solution is concluded to be sufficient, Uniqueness of nano-scale property of zinc oxide was confirmed by the higher photocatalytic activity of zinc oxide than nanosize titania particles.

  • PDF

Aerosol Characterization Study for Individual Particle of PM10, PM2.5 Observed in Industrial Area (산업단지내 미세먼지 및 토양입자의 개별입자 분석)

  • Lee, Dong-Hyun;Kim, Yong-Seok;Suh, Jeong-Min;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.7-15
    • /
    • 2013
  • Aerosol characterization study for individual particle in Busan metropolitan industrial complex was carried out from December 2010 to August 2011. SEM(scanning electron microscope)-EDX(energy dispersive x-ray) analysis was used for the analysis of 600 single particles during the sampling periods to identify non-metallic aerosol particle sources. Average $PM_{10}$ concentration was 65.5 ${\mu}g/m^3$ in summer, 104.1 ${\mu}g/m^3$ in winter during the sample periods. And Average $PM_{2.5}$ concentration was 24.5 ${\mu}g/m^3$ in summer, 64.5 ${\mu}g/m^3$ in winter individually. Particle density, enrichment factor, correlation analysis, principle component analysis were performed based on chemical composition data. Particle density distribution was measured to 2~4 $g/cm^3$, and the density of $PM_{2.5}$ was measured above 3 $g/cm^3$. In general, the elements Si, Ca, Fe and Al concentrations were higher in all samples of individual particles. The non-ferrous elements Zn, Br, Pb, Cu concentrations were higher in summer than in winter. The concentrations were not changed with the seasons because of non-ferrous industry emission pattern.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

Mass Prediction of Various Water Cluster Ions for an Accurate Measurement of Aerosol Particle Size Distribution (에어로솔 입자의 정밀입경분포 측정을 위한 물분자 클러스터 이온의 질량예측)

  • Jung, Jong-Hwan;Lee, Hye-Moon;Song, Dong-Keun;Kim, Tae-Oh
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.752-759
    • /
    • 2007
  • For an accurate measurement of aerosol particle size distribution using a differential mobility analyser (DMA), a new calculation process, capable of predicting the masses for the various kinds of water cluster ions generated from a bipolar ionizer, was prepared by improving the previous process. The masses for the 5 kinds of positive and negative water cluster ions produced from a SMAC ionizer were predicted by the improved calculation process. The aerosol particle charging ratios calculated by applying the predicted ion masses to particle charging equations were in good accordance with the experimentally measured ones, indicating that the improved calculation process are more reasonable than the previous one in a mass prediction of bipolar water cluster ions.

Study on Aerosol Deposition Behavior of Cu Films According to Particle Size (입자 사이즈에 따른 Cu 필름의 에어로졸 성막 거동에 대한 연구)

  • Lee, Dong-Won;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.235-240
    • /
    • 2017
  • The effect of particle sizes on the aerosol deposition (AD) of Cu films is investigated in order to understand the deposition behaviors of metal powder during the AD process. The Cu coatings fabricated by using $2{\mu}m$ Cu powders had a dense microstructure, a high deposition rate ($1.6{\pm}0.2{\mu}m/min$), and low resistance ($9.42{\pm}0.4{\mu}{\Omega}{\cdot}cm$) compared to that from using Cu powder with a particle size greater than $5{\mu}m$. Also, from estimating the internal micro-strain of Cu films, the Cu coatings fabricated by using $2{\mu}m$ Cu particles exhibited a high micro-strain value of $3.307{\times}10^{-3}$. On the other hand, the strain of Cu coatings fabricated with $5{\mu}m$ particles was decreased to $2.76{\times}10^{-3}$. These results seem to show that the impacted Cu particles are compressed and flattened by shock waves, and that their bonding is associated with the high internal micro-strain caused by plastic deformation.

Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001 (OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포)

  • 정창훈;전영신;최병철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

The Effect of the Spray-Dried Ceramic Granules' Compressive Strength on the Aerosol Deposition method (분무건조된 세라믹 과립분말의 압축강도가 에어로졸 데포지션 공정에 미치는 효과)

  • Kim, Jong-Woo;Ryu, Jungho;Hahn, Byung-Dong;Choi, Jong-Jin;Yoon, Woon-Ha;Ahn, Cheol-Woo;Choi, Joon-Hwan;Park, Dong-Soo
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • Recently, Aerosol Deposition method has attracted considerable attention because of its advantages to produce ceramic coatings on various substrates at room temperature. This method is strongly dependent on the raw powder, which should have high mobility with carrier gas and moderate mechanical strength to be crushed onto the substrate. In this report, the effects of the ceramic granules' compressive strength on the ceramic coating formation are discussed. The ceramic granules were prepared by spray-drying method and heat treated at various temperatures. It was found that at the moderate mechanical strength of ceramic granules gave more effective film formation behavior during Aerosol Deposition method.

Ionic composition of aerosol particles under urban atmospheres of Seoul, Korea (서울시 대기중 입자상 오염물질의 조성에 관한 연구)

  • 한진석;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.389-398
    • /
    • 1996
  • In order to understand the relative importance of various pathways leading to the production and transformation of aerosols under different atmospheric conditions, the behavior of atmospheric aerosols have been investigated using a high volume tape sample in Seoul for a week period during August 1990. The concentrations of anion $(SO^{2-}_4, NO^-_3, CI^-)$ and cation $(Ca^{2+}, Na^+, NH^+_4)$ species of aerosol samples were analyzed to identify the ionic composition of aerosols and to estimate their relative contributions to aerosol formation. The concentrations of aerosol species were calculated by a multiple regression model. The results of our calculations indicate the existence of various chemical species such as $(NH_4)_2SO_4, Na_2SO_4, CaSO_4, NH_4NO_3, NaNO_3, Ca(NO_3)_2, NH_4Cl$, and NaCl salts. According to our calculations, the most dominant species of aerosol was $(NH_4)_2SO_4$ with the mean concentration of 23.3 $/mu g/m^3$ (66.9%). The proportion of different componts with aerosol (e.g., $NH_4NO_3$ and $NH_4Cl$) was strongly affected by temperature, relative humidity, and partial presure of gases.

  • PDF

Study of aerosol-cloud interaction phenomena from satellite remote sensing and climate modeling

  • Nakajima, Teruyuki;Higurashi, Akiko;Kawamoto, Kazuaki;Okamoto, Hajime;Takemura, Toshihiko;Kuroda, Shunsuke
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.100-102
    • /
    • 1999
  • We have analyzed AVHRR global data set for obtaining aerosol and cloud microphysical parameters, i. e., optical thickness and size index of particle polydispersions. From the results, it is found that the cloud optical thickness increases with increasing aerosol column number, which seems to be caused mainly by decreasing cloud particle radius, The cloud liquid water path was observed to be relatively constant without a significant dependence on the aerosol number. Further comparison of the satellite results with a general circulation model simulation.

  • PDF

Analysis of Aerosol Dynamics, Heat and Mass Transfer in the Modified Chemical Vapor Deposition (수정된 화학증착공정에서 에어로졸 역학, 열전달 및 물질전달 해석)

  • Park, Kyong Soon;Lee, Bang Weon;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.262-271
    • /
    • 1999
  • A study of aerosol dynamics has been done to obtain axially and radially varying size distributions of particles generated in the Modified Chemical Vapor Deposition process. Heat and mass transfer have also been studied since particle generation and deposition strongly depend on the temperature field in a tube. Bimodal size distributions of particles have been obtained both in the particulate flow and in the deposited particle layer for the first time using the sectional method to solve aerosol dynamics. Variations of geometric mean diameter, geometric standard deviation have been studied for various parameters; flow rates and maximum wall temperature. The comparison between one-dimensional and two-dimensional approaches has also been made.