• 제목/요약/키워드: Aerodynamic performance

검색결과 925건 처리시간 0.036초

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

Practical countermeasures for the aerodynamic performance of long-span cable-stayed bridges with open decks

  • Zhou, Rui;Yang, Yongxin;Ge, Yaojun;Mendis, Priyan;Mohotti, Damith
    • Wind and Structures
    • /
    • 제21권2호
    • /
    • pp.223-239
    • /
    • 2015
  • Open decks are a widely used deck configuration in long-span cable-stayed bridges; however, incorporating aerodynamic countermeasures are advisable to achieve better aerodynamic performance than a bluff body deck alone. A sectional model of an open deck cable-stayed bridge with a main span of 400 m was selected to conduct a series of wind tunnel tests. The influences of five practical aerodynamic countermeasures on flutter and vortex-induced vibration (VIV) performance were investigated and are presented in this paper. The results show that an aerodynamic shape selection procedure can be used to evaluate the flutter stability of decks with respect to different terrain types and structural parameters. In addition, the VIV performance of $\prod$-shaped girders for driving comfortableness and safety requirements were evaluated. Among these aerodynamic countermeasures, apron boards and wind fairings can improve the aerodynamic performance to some extent, while horizontal guide plates with 5% of the total deck width show a significant influence on the flutter stability and VIV. A wind fairing with an angle of $55^{\circ}C$ showed the best overall control effect but led to more lock-in regions of VIV. The combination of vertical stabilisers and airflow-depressing boards was found to be superior to other countermeasures and effectively boosted aerodynamic performance; specifically, vertical stabilisers significantly contribute to improving flutter stability and suppressing vertical VIV, while airflow-depressing boards are helpful in reducing torsional VIV.

벨마우스 깊이가 다른 소형축류홴의 공력특성에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance Characteristics of a Small-Size Axial Fan with the Different Depths of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.73-78
    • /
    • 2013
  • A Small-size axial fan(SSAF) has widely been utilized to circulate a cooling air in a refrigerator, etc. Generally, the aerodynamic performance of SSAF is strongly dependent upon the depth between SSAF and bellmouth, and it includes axial, partially stalled, mostly stalled and radial flow regions according to the flow coefficient. In this study, four kinds of bellmouth depths were considered to analyze the aerodynamic performance of SSAF. As a bellmouth depth increases, a maximum flowrate decreases, but a maximum static pressure increases. Also, stall region includes an inflection point in all aerodynamic performance curves. Finally, a static pressure efficiency shows the maximum value of 37%.

자동차 차체 형태 디자인이 공기역학 성능에 미치는 영향에 대한 연구 (Research on the Effect of Car Body Design on CFD Aerodynamics Performance)

  • 김정민
    • 문화기술의 융합
    • /
    • 제6권1호
    • /
    • pp.501-506
    • /
    • 2020
  • 본 실험 연구에서는 대표적인 네 가지 타입의 승용차 차량형태에 대한 공기역학(공력) 성능 분석, 측면 유리의 각도에 따른 공력 성능 분석, 엔진후드(엔진 덮개)의 각도차이에 따른 공력 성능 분석, 루프 라인의 각도 차이에 따른 공력 성능 분석을 통해 차량의 형태 변화에 따라 공력 성능이 어떻게 변화하는지를 종합적으로 분석해 보았다. 실험결과 비스듬히 떨어지는 후면 유리 라인은 공력 성능을 저하시켰고, 루프의 각도 차이에 따른 공력 성능 차이는 거의 나타나지 않았으며 일찍 떨어지는 후면 라인은 공력 성능에 가시적인 영향을 끼치지 않았다. 차량의 루프라인이 수평으로 늦게까지 이어지다 천천히 떨어지는 후면 유리 라인은 스타일링에 도움이 될지언정 공력 성능은 저하시켰다. 후방 디퓨저의 경우 차체의 형태에 따라 그 성능 효과가 달라지는 것으로 판단되었다.

전산해석 및 풍동시험을 이용한 다기능 대기 자료 센서의 공력 설계 (AERODYNAMIC DESIGN OF A MULTI-FUNCTION AIR DATA SENSOR BY USING CFD AND WIND TUNNEL TEST)

  • 박영민;최인호;이융교;권기정;김성찬;황인희
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.32-38
    • /
    • 2010
  • Aerodynamic design of the vane type multi-function probe was tried by using CFD and wind tunnel test for the MALE UAV and small business jets. The present multi-function probe can measure total pressure, static pressure and angle of attack by using rotating vane. Therefore, major performances are determined by aerodynamic characteristics of vane. In order to design the sensor compatible to the requirement, aerodynamic characteristics of sensors were investigated by using CFD and dynamic response analysis was also performed for transient performance. The final aerodynamic performance was measured by the wind tunnel test at Aerosonic and the results were compared with the present design. The results showed that the aerodynamic design using the CFD can be successfully used for the design of vane type multi-function air data sensor.

Impacts of wind shielding effects of bridge tower on railway vehicle running performance

  • Wu, Mengxue;Li, Yongle;Zhang, Wei
    • Wind and Structures
    • /
    • 제25권1호
    • /
    • pp.63-77
    • /
    • 2017
  • When railway vehicles run by towers of long span bridges, the railway vehicles might experience a sudden load-off and load-on phenomenon in crosswind conditions. To ensure the running safety of the railway vehicles and the running comfort of the passengers, some studies were carried out to investigate the impacts of sudden changes of aerodynamic loads on moving railway vehicles. In the present study, the aerodynamic coefficients which were measured in wind tunnel tests using a moving train model are converted into the aerodynamic coefficients in the actual scale. The three-component aerodynamic loads are calculated based on the aerodynamic coefficients with consideration of the vehicle movement. A three-dimensional railway vehicle model is set up using the multibody dynamic theory, and the aerodynamic loads are treated as the inputs of excitation varied with time for kinetic simulations of the railway vehicle. Thus the dynamic responses of the railway vehicle passing by the bridge tower can be obtained from the kinetic simulations in the time domain. The effects of the mean wind speeds and the rail track positions on the running performance of the railway vehicle are discussed. The three-component aerodynamic loads on the railway vehicle are found to experience significant sudden changes when the vehicle passes by the bridge tower. Correspondingly, such sudden changes of aerodynamic loads have a large impact on the dynamic performance of the running railway vehicle. The dynamic responses of the railway vehicle have great fluctuations and significant sudden changes, which is adverse to the running safety and comfort of the railway vehicle passing by the bridge tower in crosswind conditions.

Temporary aerodynamic countermeasures for flutter suppression of a double-deck truss girder during erection

  • Zewen Wang;Bokai Yang;Haojun Tang;Yongle Li
    • Wind and Structures
    • /
    • 제38권5호
    • /
    • pp.399-410
    • /
    • 2024
  • Long-span suspension bridges located in typhoon-prone regions face significant risks of flutter instability, particularly in girder erection. Despite the implementation of aerodynamic countermeasures designed for the service stage, the flutter stability of bridge in girder erection may not meet the required standards. Nowadays, the double-deck truss girder is increasingly common in practical engineering which exhibits different performance from the single-deck truss girder. To gain insights into the flutter performance of this girder type and determine temporary aerodynamic countermeasures for flutter suppression in girder erection, wind tunnel tests were conducted. The effects of affiliated members on the flutter performance were first examined. Subsequently, different aerodynamic countermeasures were designed and their effectiveness was tested. The results indicate that the stabilizers above and below the upper and lower decks are the most effective for the flutter stability of bridge at positive and negative angles of attack, respectively. The higher the stabilizers are, the better the effect on flutter suppression achieves. Considering the feasibility in practical engineering, a temporary stabilizer above the upper deck was considered. It is expected that the results could provide references for the aerodynamic design of double-deck truss girder during erection.

유체-구조 연성해석을 이용한 능동/수동 유동제어방식이 결합된 고하중 축류 팬의 성능특성 연구 (Investigation on Aerodynamic Performance of a Highly-Loaded Axial Fan with Active/Passive Flow Control Using FSI Analysis)

  • 마상범;김광용;최재호;이원석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권1호
    • /
    • pp.113-119
    • /
    • 2017
  • An investigation on aerodynamic performance of a highly-loaded axial fan has been conducted to find the effects of tip injection and casing groove on aerodynamic performance in this study. Three-dimensional Reynolds-averaged Navier-Stokes equations with $k-{\varepsilon}$ turbulence model were used to analyze the fluid flow in the fan with Fluid-Structure Interaction (FSI) analysis. The hexahedral grid was used to construct computational domain, and the grid dependency test drew the optimal grid system. FSI analysis was also carried out to predict the deformation of rotor and stator blades, and the effect of deformation on the aerodynamic performance of axial fan was analyzed compared to the performance predicted without FSI analysis.

A review of the state-of-the-art in aerodynamic performance of horizontal axis wind turbine

  • Luhur, Muhammad Ramzan;Manganhar, Abdul Latif;Solangi, K.H.;Jakhrani, Abdul Qayoom;Mukwana, Kishan Chand;Samo, Saleem Raza
    • Wind and Structures
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2016
  • The paper presents the state-of-the-art in aerodynamic performance of the modern horizontal axis wind turbine. The study examines the different complexities involved with wind turbine blade aerodynamic performance in open atmosphere and turbine wakes, and highlights the issues which require further investigations. Additionally, the latest concept of smart blades and frequently used wind turbine design analysis tools have also been discussed. The investigation made through this literature survey shows significant progress towards wind turbine aerodynamic performance improvements in general. However, still there are several parameters whose behavior and specific role in regulating the performance of the blades is yet to be elucidated clearly; in particular, the wind turbulence, rotational effects, coupled effect of turbulence and rotation, extreme wind events, formation and life time of the wakes.

원심 압축기의 임펠러 마하수에 따른 공력성능 특성에 관한 수치해석적 연구 (A Numerical Study on Aerodynamic Performance by the Blade Mach Number of the Centrifugal Compressor)

  • 허원석;강신형
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.56-61
    • /
    • 2015
  • It is important requirement to properly evaluate the aerodynamic performance and characteristics during preliminary design of a centrifugal compressor. In this study the centrifugal compressor was calculated for variations of mass flow and blade Mach number by means of single passage steady state. A lot of quantitative performance values were obtained and through the obtained values the aerodynamic performance characteristics of designed impeller and vaned diffuser were investigated. The results were classified by blade Mach number to analyze characteristics and the aerodynamic performance was examined at choke of impeller, diffuser and separation of diffuser.