• 제목/요약/키워드: Aeration system

검색결과 296건 처리시간 0.022초

엔진 오일의 공기 혼입 발생기구에 관한 연구(I) (A Study on the Mechanism of Oil Aeration in Automotive Engines(I))

  • 이두순;김원규;오대윤;최재권
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.129-135
    • /
    • 1999
  • We developed a new measuring equipment which makes it possible to perform on-line measurements with the merits of its implicity and the time-saving characteristics. By using the newly developed measurement system, the amount of aeration is directly measured on several parameters, i.e, engine speed, oil quantity, oil deterioration, oil temperature and viscosity, etc. It showed that oil aeration is strongly related to be gas movements in crankcase and the residence time of circulating oil in oil pan. In addition, in order to clarify the mechanism of aeration and to quantify the degree of aeration, a modelling analysis to predict aeration was performed , and as a guiding parameter, Aeration Index was defined. Finally, the parameter was compared with the actual amount of aeration, and it was confirmed that they gave a good correlation with each other.

  • PDF

컴퓨터 프로그램을 이용한 엔진오일 내 공기함량 변화가 엔진윤활시스템에 미치는 영향 연구 (A Study on Effects of Oil Aeration Level on Engine Lubrication System by using Computer Program)

  • 전상명;박영환;장시열
    • Tribology and Lubricants
    • /
    • 제17권3호
    • /
    • pp.198-208
    • /
    • 2001
  • A Parametric study based on a computer analysis of the lubrication system of a four-cylinder gasoline engine is illustrated. Through the parametric study, the effects of various aeration levels on the change of oil flow rate and pressure are investigated. Also, at high oil temperature and low engine speed, the effect of oil aeration level on oil flow characteristics in lubrication system is investigated. The illustrated results may give to designers the guide lines of oil aeration level for the safe design of engine lubrication systems in terms of minimum pressure at crank oil bore.

호흡률에 기반한 연속회분식반응조의 포기공정 제어 (Aeration control based on respirometry in a sequencing batch reactor)

  • 김동한;김성홍
    • 상하수도학회지
    • /
    • 제32권1호
    • /
    • pp.11-18
    • /
    • 2018
  • As the sequencing batch reactor process is a time-oriented system, it has advantages of the flexibility in operation for the biological nutrient removal. Because the sequencing batch reactor is operated in a batch system, respiration rate is more sensitive and obvious than in a continuous system. The variation of respiration rate in the process well represented the characteristics of biological reactions, especially nitrification. The respiration rate dropped rapidly and greatly with the completion of nitrification, and the maximum respiration rate of nitrification showed the activity of nitrifiers. This study suggested a strategy to control the aeration of the sequencing batch reactor based on respirometry. Aeration time of the optimal aerobic period required for nitrification was daily adjusted according to the dynamics of respiration rate. The aeration time was mainly correlated with influent nitrogen loadings. The anoxic period was extended through aeration control facilitating a longer endogenous denitrification reaction time. By respirometric aeration control in the sequencing batch reactor, energy saving and process performance improvement could be achieved.

장기폭기식 마을배수처리에서 간헐폭기 및 DO제어에 의한 질소제거 및 에너지 절약(지역환경 \circled3) (Energy Saving and Nitrogen Removal by DO Control and Intermittent Aeration Using Extended Aeration System)

  • 김형중;김선주;단헌이
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.599-604
    • /
    • 2000
  • A laboratory scale extended aeration system was installed to study the effects of DO control and intermittent aeration on energy saving and nitrogen removal. The sensors of pH, DO, ORP, MLSS, and WT were installed in the aerator to monitor them and automatically control DO concentration as 2 mg/$\ell$. In the conditions showing nitrate knee on the ORP curves, nitrogen removal rates were kept over 91%. A 72.4 % of energy saving was achieved by intermittent aeration comparing with continuous aeration.

  • PDF

혐기조-간헐포기조-개량조로 구성된 영양소 제거 공정에서 온도의 영향 (Temperature Effect on the Nutrient Removal in the Combined Biological Nutrient Removal System (CBNR) with Anaerobic-Intermittent Aerobic-Modified Oxic Reactors)

  • 강영희;한기봉
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.639-647
    • /
    • 2006
  • The temperature effect at $20^{\circ}$ and $10^{\circ}$ on the nutrient removal efficiency was evaluated in the combined biological nutrient removal system (CBNR) with anaerobic-intermittent aerobic-oxic reactors. The test was conducted under the conditions of various ratios of intermittent aeration time and distribution of influent raw water to CBNR. The removal efficiencies of organics, nitrogen and phosphorus were a little bit better at $20^{\circ}$ than at $10^{\circ}$. However the large difference of temperature effect on the nutrient removal efficiency between $20^{\circ}$ and $10^{\circ}$ was not appeared because of highly sustained MLSS concentrations in the reactors and controlled intermittent aeration time. In the removal of phosphorus, Mode III (50/70 min in aeration on/off time, 3 times of intermittent aeration) showed more effective compared with short aeration time of Mode IV. In case of N, P removal, the denitrification rate was lower in Mode A with splitted inflow into anaerobic and intermittent aeration basins than in Mode B with sole inflow into anaerobic basin.

Aeration Factor Used To Design The Container Type of Biopile Systems for Small-Scale Petroleum-Contaminated Soil Projects

  • Jung, Hyun-Gyu
    • 한국토양비료학회지
    • /
    • 제44권2호
    • /
    • pp.316-319
    • /
    • 2011
  • Biopiles which offer the potential for cost-effective treatment of contaminated soils are above-ground, engineered systems that use oxygen to stimulate the growth and reproduction of aerobic bacteria for degradation of the petroleum constituents adsorbed to soil in excavated soils. This technology involves heaping contaminated soils into piles and stimulating aerobic microbial activity within the soils through the aeration and/or addition of minerals, nutrients, and moisture. Inside the biopile, microbially mediated reactions by blowing or extracting air through the pipes can enhance degradation of the organic contaminants. The influence of a aeration system on the biopile performance was investigated. Air pressure made to compare the efficiency of suction in the pipes showed that there were slightly significant difference between the two piles in the total amount of TPH biodegradation. The normalised degradation rate was, however, considerably higher in the aeration system than in the normal system without aeration, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile.

엔진 경사 조건이 오일 공급 시스템에 미치는 영향 (The Effect of Engine Tilting Conditions on the Oil Supply System)

  • 전문수;김숭기;박병완
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.37-43
    • /
    • 2004
  • Engine lubrication system is generally affected by vehicle driving conditions; acceleration, braking deceleration, and cornering. The oil supply system such as oil pan, baffle plate, and oil pick-up pipe should be optimized to cope with severe driving conditions. The main purpose of this paper is to understand the effect of the engine tilting angle on the oil supply system using engine tilting test rig. For the purpose, the oil pressure fluctuation and oil aeration in the main gallery are measured at various engine tilting angles. In addition, the oil flow is visualized by using transparent oil pan to investigate the cause of the formation of oil aeration. The test results show there is a strong correlation between the main gallery oil pressure fluctuation and oil aeration. It is also found that the visualization technique is helpful to stabilize the oil supply system at severe driving conditions.

식품폐수 처리 단계별 미생물 대사지문 (Metabolic Fingerprinting of Food Wastewater Treatment System)

  • 유기환;이상현;이동근
    • 한국환경보건학회지
    • /
    • 제34권4호
    • /
    • pp.327-332
    • /
    • 2008
  • To determine structure and activities of microbial communities in a food wastewater treatment system, biofilm of RABC (rotating activated Bacillus contactor) and samples of aeration tanks were analyzed. Heterotrophic bacterial concentrations were similar between biofilm and stage 1 aeration tank and decreased 2-log at stage 3 aeration tank as dissolved oxygen decreased, however portions of Bacillus groups were increased at stage 3 aeration tank. It was revealed by quantitative and qualitative analysis of metabolic fingerprinting patterns of Biolog GN2 plate that RABC represented much higher activities and a different microbial community structure compared to aeration tanks. Metabolic fingerprinting showed the carbon sources that isolated Bacillus groups could or could not use, were used similarly meaning that not only Bacillus groups but also other microbial groups would contribute to the treatment of wastewater.

Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정 (Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test)

  • 김철웅;임세호;신동록;이지영;박재한;안윤희;고광백
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

The Processing of Livestock Waste Through the Use of Activated Sludge - Treatment with Intermittent Aeration Process -

  • Osada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권5호
    • /
    • pp.698-701
    • /
    • 2000
  • To prevent surface and underground water pollution, wastewater treatment is essential. Four bench-scale activated sludge units (10 L operational volumes) were operated at 5, 10 and $20^{\circ}C$ for evaluation of treatment efficiencies with typical wastewater from swine housing. The units were set for a 24-hour cycle. As compared to the conventional process, high removal efficiencies for organic substances, nitrogen and phosphorus in swine wastewater were obtained simultaneously with an intermittent aeration process (lAP). The NOx-N produced during an aeration period was immediately reduced to nitrogen gas (e.g. $N_2$ or $N_2O$) in the subsequent non-aeration periods, and nitrification in aeration periods occurred smoothly. Under these conditions, phosphorus removal occurred with the release of phosphorus during the non-aeration periods followed by the excess uptake of phosphorus in the activated sludge during aeration periods. It was confirmed that the lAP had a better ability to remove pollutants under both low temperatures and high nitrogen loading conditions than the ordinary method did. In addition to that, the total emission of $N_2O$ from lAP was reduced to approximately 1/50 of the conventional process for the same loading. By adopting an adequate aeration programme for individual swine wastewater treatment, this system will provide a promising means for nitrogen and phosphorus control without pH control or addition of methanol.