• Title/Summary/Keyword: Advanced medical device

Search Result 134, Processing Time 0.021 seconds

A Study on Safety and Performance Evaluation of Micro - surgical Robots Based on Open Robot Platform (개방형 로봇 플랫폼 기반 미세수술로봇의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.206-214
    • /
    • 2019
  • Surgical methods and associated precision systems have been developed, but surgical procedures that require precise location and fine manipulation of the lesion remain a limitation. The combination of precision robot manipulation technology and 3D medical image navigation technology overcomes the limitations of minimally invasive surgery (MIS) and enables a more stable and successful operation. Surgical robots are surgical robots such as da Vince, and surgical robots using industrial robotic arms. There are various developments and researches of medical robots. In recent medical robot development, a new type of surgical robot based on an industrial robot arm capable of easily replacing the end effector according to the user's needs is being actively developed at home and abroad. Therefore, in this study, we developed safety and performance evaluation guideline for micro - surgical robots based on open robot platform using general purpose robot arm to help quality control of the medical device.

An Efficiency of Diagnostic Ultrasonography in Taking Side View of Medical Examination (진사적(診査的) 측면(側面)에서 본 초음파진단(超音波診斷)의 효율성(效率性))

  • Moon, Soo-Hyung;Han, Hye-Jin;Kim, Kang-Sueck
    • The Journal of the Korean life insurance medical association
    • /
    • v.1 no.1
    • /
    • pp.123-132
    • /
    • 1984
  • Among the person who want to insure, there are not only fair persons who want to become the insurance with not realizing that one was not infected with certain disease but also someones on purpose to overcome the disease through the insurance company with be recognized by oneselves. However, it was found that the ultrasonography and exact effects of medical examination with the existing medical equipments of the insurance company could not be expected. We present some several proven examples for the purpose of getting the advanced effects in medical examination by utilizing the ultrasonic device which is not harmful to human body presently as far as known. We could find affirmation through the check of ultrasonography from 907 cases, in our Department of Medical selection that many portion of the cases checked the medical examination have the present condition of illness even though they enjoy social life with good health and finally the conclusions we have learned are as follows; The aged cases show the increase of rate of possessing disease and man shows 2.2 times of possessing disease than woman. Fatty infiltration of liver take portion of 74.7% from the case checked. 12 cases of cholelithiasis are not conscious of symptom at all. Through the check of ultrasonography in obstetrics and gynecology, myoma uteri be showed high rate of 72.2% from the case of possessing disease. In Case of the potential pregnancing woman it made clear to find pregnancy which was undistincted still more also know the existence and nonexistence of fetal death when pregnancy expected.

  • PDF

The Development of Safety and Essential Performance Criteria for Lower Extremity Robotic Assisted Gait Training System (하지 로봇재활의료기기의 안전성 및 필수성능 평가 기준 개발)

  • Yong Wan Kang;Ji Yean Kwon
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.190-203
    • /
    • 2023
  • The purpose of this study is to provide basic data to ensure the safety and essential performance of a Lower Extremity robotic assisted gait training system and to provide advanced technology and technical basis to the industry handling the system. Based on IEC 60601-1:2012/AMD2:2020 (Medical Electrical Equipment - General requirements for basic safety and essential performance of medical electrical equipment), IEC 62366-1:2015/AMD1:2020 (Medical devices - Part 1: Application of usability engineering to medical devices) and EN ISO 14971:2019 (Medical devices - Application of risk management to medical devices), the requirements for ensuring the safety and essential performance of the Lower Extremity robotic assisted gait training system were derived. Through the Delphi survey method and scenario analysis, which reflects the opinions and knowledge of experts in the fields of development, testing and review of technical documents, and quality assurance of medical devices, validity and reliability were conducted and obtained results with adequate content validity ratio (CVR; 0.7≤) and excellent reliability (Cronbach's α; 0.9≤). As a result, it was confirmed that the reliability and validity of the risk management process to ensure the safety and essential performance of the Lower Extremity robotic assisted gait training system are required a model can be established to provide measures to reduce risks according to the level of risk exposure caused by usage.

Design and Implementation of Message Format and Server for Interworking EMR System and Gateway of Medical Devices (의료기기 통합 게이트웨이와 EMR 시스템간의 연동을 위한 메시지 규격 설계 및 서버 구현)

  • Im, Seokjin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.255-262
    • /
    • 2013
  • Medical Gateway(MG), that integrates medical devices with its unique data format in various hospital information systems, provides effectiveness in the cost of the management unlike existing systems that uses PC as a gateway to hospital information systems because MG enables to interface medical devices with itself. However, in spite of using MG for integrating medical devices, we need additional programs or systems to interwork with EMR system of each hospital in accordance with the configuration of DB. In this paper, we design and implement the format of medical information and server system for interworking MG with EMR system. The proposed system makes easy exchanging medical data between MG and EMR system. Thus, the proposed system can contribute to a national project to export abroad advanced hospital setup converged with IT.

New Standards for Determining Unlicensed Practice of Korean Medicine Doctors - Focusing on the Supreme Court's Decision No. 2016do21314 - (한의사의 면허외 행위 판단의 새로운 기준 -대법원 2022. 12. 22. 선고 2016도21314 전원합의체 판결을 중심으로-)

  • CHOI HYUG YONG
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.1
    • /
    • pp.131-155
    • /
    • 2023
  • Medical act divides unlicensed medical practice into medical practice by non-medical practitioners and unlicensed practice by medical practitioners. In the past, it was a common approach to strictly distinguish between western and Korean medicine, but the Supreme Court's Decision of December 22, 2016, Do. 21314, provided a new direction regarding the criteria for determining whether a Korean medicine practitioner is acting outside license. This paper analyzes the new criteria in detail, examines the significance of the new criteria, and explores its impact on the dualistic medical system. The difference between the new criteria and the previous criteria in the precedents is that the judgment is not based on the connection between Korean medicine principles and Western medicine principles. It is an advanced standard that actively accepts the overlap and variability of medical practice, moving away from dichotomous thinking that exclusively distinguishes between Korean medicine and Western medicine.

A Study on the Facial Expression Recognition using Deep Learning Technique

  • Jeong, Bong Jae;Kang, Min Soo;Jung, Yong Gyu
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.60-67
    • /
    • 2018
  • In this paper, the pattern of extracting the same expression is proposed by using the Android intelligent device to identify the facial expression. The understanding and expression of expression are very important to human computer interaction, and the technology to identify human expressions is very popular. Instead of searching for the symbols that users often use, you can identify facial expressions with a camera, which is a useful technique that can be used now. This thesis puts forward the technology of the third data is available on the website of the set, use the content to improve the infrastructure of the facial expression recognition accuracy, to improve the synthesis of neural network algorithm, making the facial expression recognition model, the user's facial expressions and similar expressions, reached 66%. It doesn't need to search for symbols. If you use the camera to recognize the expression, it will appear symbols immediately. So, this service is the symbols used when people send messages to others, and it can feel a lot of convenience. In countless symbols, there is no need to find symbols, which is an increasing trend in deep learning. So, we need to use more suitable algorithm for expression recognition, and then improve accuracy.

Iot Based Vision and Remote Control a Compact Mobile Robot System (IoT 기반의 비전 및 원격제어 소형 이동 로봇 시스템)

  • Jeon, Yun Chae;Choi, Hyeri;Yoon, Ki-Cheol;Kim, Gwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.267-273
    • /
    • 2021
  • Recently, the small-size mobile robots with remote-control are rapidly growth which market of mobile is increased in the world. Especially, the smart-phones are widely used for interface device in the small size of a mobile robot. The research goal is control system design which is applied to miniaturization of a mobile robot using smart-phone and it can be confirmed performance for designed system. Meanwhile, the fabrication of mini-mobile robot can also be remote-control operation through the WIFI performance of a smart-phone. The smart-phone is used to remote-control for robot operation which control data transmit to robot via the WIFI network. To drive the robot, we can observe by the smart-phone screen and it can easily adjust the robot drive condition and direction by smart-phone button. Consequentially, there was no malfunction and images were printed out well. However, in drive, because of blind spot, robot was bumped into obstacle. Therefore, the additional test is necessary to sensor for blind spot which sensor can be equipment to mobile robot. In addition, the experiment with robot object recognition is needed.

Stereotactic Radiosurgery

  • Chung, Hyun-Tai;Lee, Dong-Joon
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.63-70
    • /
    • 2020
  • Stereotactic radiosurgery is one of the most sophisticated forms of modern advanced radiation therapy. Unlike conventional fractionated radiotherapy, stereotactic radiosurgery uses a high dose of radiation with steep gradient precisely delivered to target lesions. Lars Leksell presented the principle of radiosurgery in 1951. Gamma Knife® (GK) is the first radiosurgery device used in clinics, and the first patient was treated in the winter of 1967. The first GK unit had 179 cobalt 60 sources distributed on a hemispherical surface. A patient could move only in a single direction. Treatment planning was performed manually and took more than a day. The latest model, Gamma Knife® IconTM, shares the same principle but has many new dazzling characteristics. In this article, first, a brief history of radiosurgery was described. Then, the physical properties of modern radiosurgery machines and physicists' endeavors to assure the quality of radiosurgery were described. Intrinsic characteristics of modern radiosurgery devices such as small fields, steep dose distribution producing sharp penumbra, and multi-directionality of the beam were reviewed together with the techniques to assess the accuracy of these devices. The reference conditions and principles of GK dosimetry given in the most recent international standard protocol, International Atomic Energy Agency TRS 483, were shortly reviewed, and several points needing careful revisions were highlighted. Understanding the principles and physics of radiosurgery will be helpful for modern medical physicists.

A Study on the X-ray Image Reading of Radiological Dispersal Device (방사능 폭발물의 X-ray 영상판독에 관한 연구)

  • Geun-Woo Jeong;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.

Phase-Separation Properties of Poly(Ethylene Glycol) had Dextran Solutions In Microfluidic Device (미세 유체장치 내에서 Poly(Ethylene Glycol)과 Dextran 용액의 상 형성 특성 연구)

  • Choi, Joo-Hyung;Chang, Woo-Jin;Lee, Sang-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.244-249
    • /
    • 2007
  • Fluidic conditions for the separation of phases were surveyed in a microfluidic aqueous two-phase extraction system. The infusion ratio between polyethylene glycol (PEG) and dextran solution defines the concentrations of each polymer in micro-channel, which determine the phase-separation. The appropriate ratio between PEG (M.W. 8000, 10%, w/v) and dextran T500 (M.W. 500000, 5%, w/v) in order to perform the separation of phases of both polymers was observed as changing the mixed ratio of both polymers. Based on the fluidic conditions, stable two-phase solutions were obtained within 4% to 8% and 3% to 1% of PEG and dextran, respectively. In addition, the characteristics of the two-phase were discussed. The separation technique studied in the paper can be applied for the implementation of a lab-on-a chip which can detect various biological entities such cells, bacterium, and virus in an integrated manner using built in a biosensor inside the chip.