DOI QR코드

DOI QR Code

Phase-Separation Properties of Poly(Ethylene Glycol) had Dextran Solutions In Microfluidic Device

미세 유체장치 내에서 Poly(Ethylene Glycol)과 Dextran 용액의 상 형성 특성 연구

  • 최주형 (인하대학교 생물공학과) ;
  • 장우진 (인하대학교 초정밀생물분리기술연구센터) ;
  • 이상우 (연세대학교 의공학부)
  • Published : 2007.04.30

Abstract

Fluidic conditions for the separation of phases were surveyed in a microfluidic aqueous two-phase extraction system. The infusion ratio between polyethylene glycol (PEG) and dextran solution defines the concentrations of each polymer in micro-channel, which determine the phase-separation. The appropriate ratio between PEG (M.W. 8000, 10%, w/v) and dextran T500 (M.W. 500000, 5%, w/v) in order to perform the separation of phases of both polymers was observed as changing the mixed ratio of both polymers. Based on the fluidic conditions, stable two-phase solutions were obtained within 4% to 8% and 3% to 1% of PEG and dextran, respectively. In addition, the characteristics of the two-phase were discussed. The separation technique studied in the paper can be applied for the implementation of a lab-on-a chip which can detect various biological entities such cells, bacterium, and virus in an integrated manner using built in a biosensor inside the chip.

Keywords

References

  1. A. Manz, J. Harrison, E.M.J. Verpoorte, J.C. Fettinger, A. Paulus, H. Ludi and H.M. Widmer, 'Planar chips technology for miniaturization and integration of separation techniques into monitoring systems : Capillary electrophoresis on a chip,' J. Chromo A, vol. 593, pp. 243-252, 1992 https://doi.org/10.1016/0021-9673(92)80292-3
  2. D.J. Harrison, A. Manz, Z. Fan, H. Luedi and H.M. Widmer, 'Capillary electrophoresis and sample injection systems integrated on a planar glass chip,' Anal. Chem., vol. 64, pp. 1920-1925, 1992 https://doi.org/10.1021/ac00041a029
  3. A.G. Hadd, D.E. Raymond, J.W. Halliwell, S.C. Jacobson and J.M. Ramsey, 'Microchip device for performing enzyme assays,' Anal. Chem., vol. 69, pp. 3407-3412, 1997 https://doi.org/10.1021/ac970192p
  4. G.M. Whitesides, 'The origins and the future of microfluidics,' nature, vol. 442, pp. 368-373, 2006 https://doi.org/10.1038/nature05058
  5. J.C Yoo, M.C. Moon, Y.J. Choi, C.J. Kang and Y.S. Kim, 'A high performance micro fluidic system integrated with the micropump and microvalve on the same substrate,' Microelec. Eng., vol. 83, pp.1684-1687, 2006 https://doi.org/10.1016/j.mee.2006.01.202
  6. V. Hessel, H. Lowe and F. Schonfeld, 'Micromixers a review on passive and active mixing principles,' Chem. Eng. SCi., vol. 60, pp. 2479-2501, 2005 https://doi.org/10.1016/j.ces.2004.11.033
  7. W.R. Vandaveer IV, S.A. Pasas, R.S. Martin and S.M. Lunte, 'Recent developments in amperometric detectionfor microchip capillary electrophoresis,' Electrophoresis, vol. 23, pp. 3667-3677, 2002 https://doi.org/10.1002/1522-2683(200211)23:21<3667::AID-ELPS3667>3.0.CO;2-W
  8. I. Rodriguez, Y. Zhang, H.K. Lee and S.F.Y. Li, 'Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and micro fabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin G,' J. Chrom. A, vol. 781, pp. 287-293, 1997 https://doi.org/10.1016/S0021-9673(97)00667-5
  9. E.K. Zholkovskij and J.H. Masliyah, 'Hydrodynamic dispersion due to combined pressure-driven and electroosmotic flow through microchannels with a thin double layer,' Anal. Chem., vol. 76, pp. 2708-2718, 2004 https://doi.org/10.1021/ac0303160
  10. F.E. Regnier, B. He, S. Lin and J. Busse, 'Chromatography and electrophoresis on chips: critical elements of future integrated, microfluidic analytical systems for life science,' TIBTech, vol. 17, pp. 101-106, 1999 https://doi.org/10.1016/S0167-7799(98)01294-3
  11. K. Choi, Y. Kim and D.S. Chung, 'Liquid-Phase microextraction preconcentration electrophoresis,' Anal. Chem., vol. 76, pp. 855-858, 2004 https://doi.org/10.1021/ac034648g
  12. C. Malhaire, A. Didiergeorges, M. Bouchardy and D. Barbier, 'Mechanical characterizationand reliability study of bistable SiO2/Si membranes for microfluidic applications,' Sens. Act. A, vol. 99, pp.216-219, 2002 https://doi.org/10.1016/S0924-4247(01)00891-3
  13. G.M. Zijlstra, C.D. De gooijer and J. Tramper, 'Extractive bioconversions in aqueous two-phase systems,' Curr. Opinion in Biotech.,vol.9,pp.171-176, 1998 https://doi.org/10.1016/S0958-1669(98)80111-0
  14. G. Johansson and F. Tjerneld, 'Affinity Partitioning,' Highly Selective Separations in Biotechnology, G. Street eds., Blackie Academic and Professional, Bishopbriggs, 1994
  15. P.A. Albertsson and F. Tjerneld, 'Phase Diagrams', Methods in Enzymology, Aqueous Two-Phase Systems, H. Walter and G. Johansson, eds, Academic Press, Inc., San Diego, 1994
  16. J.F. Hamel, J.B. Hunter and S.K. Sikdar, 'Modeling and Applications of Downstream Processing: A survey of innovative strategies,' Downstream Processing and Bioseparation : Recovery and purification of biological products, J.F.P. Hamel and J.B. Hunter, eds., ACS Symposium Series, Toronto, 1988
  17. H. Hustedt, K.H. Kroner and M.R. Kula, 'Applications of Phase Partitioning in Biotechnology,' Partitioning in Aqueous Two-Phase Systems : Theory, methods, uses, and applications to biotechnology, H. Walter, Brooks, D.E. and D. Fisher, eds., Academic Press Inc. Orlando, 1985
  18. M. Yamada, V. Kasim, J. Edahiro and M. Seki, 'Continuous cell partitioning using an aqueous two-phase flowsystem in microfluidic devices,' Biotech. and Bioeng., vol. 87, pp. 489-494, 2004
  19. K.H. Nam, W.J. Chang, H. Hong, S.M. Lim, D.I. Kim and Y.M. Koo, 'Continuous-flow fractionation of animal cells in microfluidic device using aqueous two-phase extraction,' Biomed. Microdev., vol. 7, no.3, pp. 189-195, 2005 https://doi.org/10.1007/s10544-005-3025-6
  20. C.S. Effenhauser, G.J.M. Bruin, A. Paulus and M. Ehrat, 'Integrated capillary electrophoresis on flexible silicone microdevices: analysis of DNA restriction fragments and detection of single DNA molecules on microchips,' Anal. Chem., vol. 69, pp. 3451-3457, 1997 https://doi.org/10.1021/ac9703919
  21. D.C. Duffy, J.C McDonald, O.J.A. Schueller and G.M. Whitesides, 'Rapid prototyping of microfluidic systems in poly (dimethylsiloxane) ,' Anal. Chem., vol. 70, pp. 4974-4984, 1998 https://doi.org/10.1021/ac980656z
  22. Y. Shibusawa, T. Fujiwara, H. Shindo and Y. Ito, 'Purification of alcohol dehydrogenase from bovine liver crude extract by dyeligand affinity counter-current chromatography,' J. Chrom. B, vol. 799, pp. 239-244, 2004 https://doi.org/10.1016/j.jchromb.2003.10.039
  23. S. Ghosh, R. Vijayalakshmi, and T. Swaminathan, 'Evaluation of an alternative source of dextran as a phase forming polymer for aqueous two-phase extractive system,' Biochem. Eng. J., vol. 21, pp. 241-252, 2004 https://doi.org/10.1016/j.bej.2004.07.005