• Title/Summary/Keyword: Advanced imaging

Search Result 838, Processing Time 0.032 seconds

Significance of the Failure Patterns in Cervical Lymph Nodes Achieving a Complete Response to Radical Radiotherapy (근치적 방사선치료에 완전반응을 보인 경부 림프절에서의 재발 양상 및 그 의의)

  • Nam, Ji-Ho;Kim, Won-Taek;Ki, Yong-Kan;Kim, Dong-Hyun;Choi, Young-Jin;Cho, Kyu-Sup;Lee, Jin-Choon;Lee, Byung-Joo;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Purpose: This study was performed to examine the neck failure patterns after a complete response (CR) to definitive radiotherapy for advanced head and neck cancer patients, as well as evaluate the clinical significance of the results of this study. Materials and Methods: Between 1987 and 2008, the clinical data of patients who had been treated with radical radiotherapy for primary squamous cell carcinomas and enlarged cervical lymph nodes was analyzed retrospectively. Ultimately, the cases that showed CR of the cervical lymph node lesions to full-dose radiotherapy were included in this study. The recurrent rate and sites in the cervical lymphatic area were evaluated periodically by radiologic imaging studies, along with some factors which might have affected the rate of recurrence. Results: A total of 73 patients who achieved CR in neck area after radiotherapy were included in this study. The rate of subsequent neck failure among those patients was 19.2%. There was only a 5.5% failure rate in the 55 patients who underwent radiotherapy in their primary site. Eighty percent of the recurrent cases were found within 3 years (median follow-up, 68 months). The majority of neck recurrent cases (47%) were accompanied with the failure of the primary lesions. The initial response of the primary site and the method of radiotherapy simulation were significant prognostic factors associated with the nodal recurrence rate. Conclusion: The recurrence rate of cervical nodes in patients with CR to radiotherapy in the primary site and neck area was about 5%. These patients could be followed up with close observation without a planned neck dissection.

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF

Clinical Features of Patients with Stage IV Gastric Cancer (4기 위암 환자의 임상적 특성)

  • Kim, Yoo Seok;Kim, Sung Soo;Min, Young Don
    • Journal of Gastric Cancer
    • /
    • v.8 no.2
    • /
    • pp.91-96
    • /
    • 2008
  • Purpose: The early detection of gastric cancer and accuracy of preoperative staging has currently been on the increase due to the development of endoscopy and imaging techniques, but there are still many cases of advanced gastric cancer detected at the first diagnosis and there are also many cases of stage IV gastric cancer diagnosed after a postoperative pathological examination. Although the prognosis of stage IV gastric cancer is very poor, this study was performed to determine the value of the use of aggressive treatment determined after a clinical analysis. Materials and Methods: We retrospectively analyzed 150 patients that were diagnosed with stage IV gastric cancer among 1376 patients who underwent a laparotomy for gastric cancer from January 1994 to December 2006. Results: Of the 150 patients with stage IV gastric cancer who underwent a laparotomy, there were 104 men and 46 women. The mean patient age was 57.8 years (age range, 28~93 years). A subtotal gastrectomy or total gastrectomy was performed in 119 patients and 31 patients underwent an explorative laparotomy. The mean survival time of patients that underwent a gastrectomy and patients that did not undergo a gastrectomy was 722 days (range, 14~4,559 days) and 173 days (range, 16~374 days), respectively this result was statistically significant. When patients that underwent a gastrectomy were classified according to the TNM stage, the mean survival time of 33 patients with stage T4 disease was 534 days (range, 17~3,378 days) and the mean survival time of 63 patients with stage N3 disease was 521 days (range, 14~4,190 days), but there was no statistical significance. Chemotherapy was administered to 98 patients and 52 patients did not receive chemotherapy. The mean survival time of patients that received chemotherapy was 792 days (range, 36~4,559 days) and the mean survival time of patients that did not receive chemotherapy was 243 days (range, 14~2,413 days), with statistical significance. Conclusion: If there is no evidence of distant metastasis in stage IV gastric cancer, one can expect improvement of the survival rate by the use of aggressive treatment, including curative gastric resection with radical lymph node dissection and chemotherapy.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

Prognostic Significance of Pre-operative FDG-PET in Colorectal Cancer Patients with Hepatic Metastasis (대장직장암 간전이 환자에서 수술전 FDG PET의 예후인자로서의 중요성)

  • Lee, Hyo-Sang;Lee, Won-Woo;Kim, Duck-Woo;Kang, Sung-Bum;Lee, Kyoung-Ho;Lee, Keun-Wook;Kim, Jee-Hyun;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.429-435
    • /
    • 2009
  • Purpose: The purpose of this study was to assess the prognostic value of preoperative FDG-PET in colorectal cancer (CRC) patients with hepatic metastasis (HM). Materials and Methods: 24 CRC patients (M:F=14:10; age, $63{\pm}10$ yrs) with HM who had undergone preoperative FDG PET were included. Cure-intent surgery was performed in all the patients and HMs were controlled using resection (n=13), radio-frequency ablation (RFA) (n=7), and resection plus RFA (n=4). Potential prognostic markers tested were maxSUV of primary tumor, maxSUV of HM, maxSUV ratio of HM over primary tumor (M/P ratio), histologic grade, CEA level, venous/lymphatic/nerve invasion, T stage, N stage, no. of HM, no. of lymph node metastasis, and treatment modality of HM. Results: 14 CRC patients developed a recurrence with a median follow-up duration of 244 days, whereas 10 patients did not develop recurrence with a median follow-up duration of 504 days. M/P ratios but other potential prognostic markers were significantly higher in the recurrent patients ($0.72{\pm}0.14$) than recurrence-free patients ($0.54{\pm}0.23$) (p=0.038). M/P ratio only was found to predict recurrence by Cox multivariate analysis (hazard ratio 37.7, 95% confidence interval 2.01-706.1, p=0.016). The 11 patients with lower M/P ratio of <0.61 had significantly better disease-free survival rate than the 13 patients with higher M/P ratio (${\geq}0.61$) (p=0.026). Conclusion: maxSUV ratio of HM over primary tumor (M/P ratio) may be useful for prognosis prediction of CRC patients with HM. Higher FDG uptake of HM than that of primary tumor may indicate a more advanced status in stage IV CRC.

Evaluation of the Satellite-based Air Temperature for All Sky Conditions Using the Automated Mountain Meteorology Station (AMOS) Records: Gangwon Province Case Study (산악기상관측정보를 이용한 위성정보 기반의 전천후 기온 자료의 평가 - 강원권역을 중심으로)

  • Jang, Keunchang;Won, Myoungsoo;Yoon, Sukhee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Surface air temperature ($T_{air}$) is a key variable for the meteorology and climatology, and is a fundamental factor of the terrestrial ecosystem functions. Satellite remote sensing from the Moderate Resolution Imaging Spectroradiometer (MODIS) provides an opportunity to monitor the $T_{air}$. However, the several problems such as frequent cloud cover and mountainous region can result in substantial retrieval error and signal loss in MODIS $T_{air}$. In this study, satellite-based $T_{air}$ was estimated under both clear and cloudy sky conditions in Gangwon Province using Aqua MODIS07 temperature profile product (MYD07_L2) and GCOM-W1 Advanced Microwave Scanning Radiometer 2 (AMSR2) brightness temperature ($T_b$) at 37 GHz frequency, and was compared with the measurements from the Automated Mountain Meteorology Stations (AMOS). The application of ambient temperature lapse rate was performed to improve the retrieval accuracy in mountainous region, which showed the improvement of estimation accuracy approximately 4% of RMSE. A simple pixel-wise regression method combining synergetic information from MYD07_L2 $T_{air}$ and AMSR2 $T_b$ was applied to estimate surface $T_{air}$ for all sky conditions. The $T_{air}$ retrievals showed favorable agreement in comparison with AMOS data (r=0.80, RMSE=7.9K), though the underestimation was appeared in winter season. Substantial $T_{air}$ retrievals were estimated 61.4% (n=2,657) for cloudy sky conditions. The results presented in this study indicate that the satellite remote sensing can produce the surface $T_{air}$ at the complex mountainous region for all sky conditions.

Trends in QA/QC of Phytoplankton Data for Marine Ecosystem Monitoring (해양생태계 모니터링을 위한 식물플랑크톤 자료의 정도 관리 동향)

  • YIH, WONHO;PARK, JONG WOO;SEONG, KYEONG AH;PARK, JONG-GYU;YOO, YEONG DU;KIM, HYUNG SEOP
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.220-237
    • /
    • 2021
  • Since the functional importance of marine phytoplankton was firstly advocated from early 1880s massive data on the species composition and abundance were produced by classical microscopic observation and the advanced auto-imaging technologies. Recently, pigment composition resulted from direct chemical analysis of phytoplankton samples or indirect remote sensing could be used for the group-specific quantification, which leads us to more diversified data production methods and for more improved spatiotemporal accessibilities to the target data-gathering points. In quite a few cases of many long-term marine ecosystem monitoring programs the phytoplankton species composition and abundance was included as a basic monitoring item. The phytoplankton data could be utilized as a crucial evidence for the long-term change in phytoplankton community structure and ecological functioning at the monitoring stations. Usability of the phytoplankton data sometimes is restricted by the differences in data producers throughout the whole monitoring period. Methods for sample treatments, analyses, and species identification of the phytoplankton species could be inconsistent among the different data producers and the monitoring years. In-depth study to determine the precise quantitative values of the phytoplankton species composition and abundance might be begun by Victor Hensen in late 1880s. International discussion on the quality assurance of the marine phytoplankton data began in 1969 by the SCOR Working Group 33 of ICSU. Final report of the Working group in 1974 (UNESCO Technical Papers in Marine Science 18) was later revised and published as the UNESCO Monographs on oceanographic methodology 6. The BEQUALM project, the former body of IPI (International Phytoplankton Intercomparison) for marine phytoplankton data QA/QC under ISO standard, was initiated in late 1990. The IPI is promoting international collaboration for all the participating countries to apply the QA/QC standard established from the 20 years long experience and practices. In Korea, however, such a QA/QC standard for marine phytoplankton species composition and abundance data is not well established by law, whereas that for marine chemical data from measurements and analysis has been already set up and managed. The first priority might be to establish a QA/QC standard system for species composition and abundance data of marine phytoplankton, then to be extended to other functional groups at the higher consumer level of marine food webs.