• 제목/요약/키워드: Advanced Power Reactor+

검색결과 413건 처리시간 0.037초

Hot and average fuel sub-channel thermal hydraulic study in a generation III+ IPWR based on neutronic simulation

  • Gholamalishahi, Ramin;Vanaie, Hamidreza;Heidari, Ebrahim;Gheisari, Rouhollah
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1769-1785
    • /
    • 2021
  • The Integral Pressurized Water Reactors (IPWRs) as the innovative advanced and generation-III + reactors are under study and developments in a lot of countries. This paper is aimed at the thermal hydraulic study of the hot and average fuel sub-channel in a Generation III + IPWR by loose external coupling to the neutronic simulation. The power produced in fuel pins is calculated by the neutronic simulation via MCNPX2.6 then fuel and coolant temperature changes along fuel sub-channels evaluated by computational fluid dynamic thermal hydraulic calculation through an iterative coupling. The relative power densities along the fuel pin in hot and average fuel sub-channel are calculated in sixteen equal divisions. The highest centerline temperature of the hottest and the average fuel pin are calculated as 633 K (359.85 ℃) and 596 K (322.85 ℃), respectively. The coolant enters the sub-channel with a temperature of 557.15 K (284 ℃) and leaves the hot sub-channel and the average sub-channel with a temperature of 596 K (322.85 ℃) and 579 K (305.85 ℃), respectively. It is shown that the spacer grids result in the enhancement of turbulence kinetic energy, convection heat transfer coefficient along the fuel sub-channels so that there is an increase in heat transfer coefficient about 40%. The local fuel pin temperature reduction in the place and downstream the space grids due to heat transfer coefficient enhancement is depicted via a graph through six iterations of neutronic and thermal hydraulic coupling calculations. Working in a low fuel temperature and keeping a significant gap below the melting point of fuel, make the IPWR as a safe type of generation -III + nuclear reactor.

W/H형 원전 시뮬레이터용 핵 증기공급 계통 열수력모델 ARTS(Advanced Real-time Thermal Hydraulic Simulation)의 보조계산체계 개발 (Development of Backup Calculation System for a Nuclear Steam Supply System Thermal-Hydraulic Model ARTS (Advanced Real-time Thermal Hydraulic Simulation) of the W/H Type NPP)

  • 서재승;전규동
    • 에너지공학
    • /
    • 제13권1호
    • /
    • pp.51-59
    • /
    • 2004
  • 국내에 설치 운영중인 원전 훈련용 시뮬레이터의 핵 증기공급 계통 열수력 프로그램은 1980련 전후에 외국 벤더들이 개발하여 공급한 것으로 이들 열수력 프로그램은 핵 증기공급 계통 열수력 현상을 실시간으로 모의하기 위해 과도하게 단순화된 모델을 채택하고 있다. 그 결과 원자로 냉각계통에 복잡한 이상유동이 발생하는 사고를 모의하는 경우 정확도가 떨어질 수 있어 부정적인 훈련(Negative training)을 초래할 가능성이 있다. 이와같은 문제를 해결하기 위해 전력연구원에서는 RETRAN-3D코드를 기본으로 시뮬레이터용 핵 증기공급 계통 열수력 프로그램 ARTS코드를 개발하였다. RETRAN-3D코드를 기본으로 하는 ARTS코드는 거의 대부분의 사고를 실시간으로 모의할 수 있으며 계산의 건전성도 보장된다. 그러나, 대형냉각재 상실사고나 저압 저유속 상태의 장기 과도현상 등을 모의하는 경우에 발생하는 계산실패나 실시간 계산 지체등의 가능성이 있다. 이 경우 이를 자동으로 대체 보완할 수 있는 보조계산체계를 개발했다. 특히, ARTS코드의 실시간 계산 및 건전성 문제가 예상되는 대형냉각재 상실사고를 주모의 대상으로 간주했다. 계산 결과는 코드의 정확도, 실시간 계산능력, 건전성 및 운전원 교육등에서 최종안정성평가보고서 및 ANSI/ANS-3.5-1998$^{[1]}$ 시뮬레이터 소프트웨어 기준을 만족하는 것으로 평가되었다

600MW(e) CANDU PHTS Flow Instability and Interconnect Effect

  • Won Jae Lee;Jin Soo Kim;Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.290-301
    • /
    • 1985
  • 600MW(e)급 CANDU형 원자로의 1차 냉각재계통은 2개의 “8자” 모양 루프로 구성되며 정상운전중 원자로 출구헤더 (ROH)의 설계 quality는 4%이다. 이러한 루프내 2부분에 압축성 유체의 존재 및 유동-quality-기포율의 정궤환 효과는 1차 냉각재계통 유동 불안정의 주요인이 된다. 계통의 안정을 위하여 설계 변경사항으로서 같은 루프의 ROH-HOH간 interconnect가 설치되었다. 본 논문은 정상운전시 1차 냉각재계통의 유동 불안정현상을 조사연구하며, 또한 interconnect가 유동 안정성에 미치는 영향 및 계통 고유의 유동 안정성에 대한 연구를 수행한다. 시간 영역의 안정성 분석은 ATHER코드로부터 보완된 ATHER/MOD-I 코드를 사용하여 분석한다. 가장 보수적인 계통 모형, 즉 대칭형 루프의 유동은 발산하며, interconnect를 설치함으로써 계통의 유동 안정성은 크게 향상되어 안정된다. 그러나 보수적인 가압기 모델을 사용 분석하였을 경우라도 계통의 유동 안정성은 보장됨을 알 수 있다. 실제적인 계통 즉 가압기와 interconnect를 모사한 경우의 계통 안정성은 크게 보장된다. 결론적으로 비록 interconnect는 계통의 안정성을 크게 향상시키나 가압기 등 계통 고유의 유동 안정성은 매우 커서 interconnect가 설치되지 않았더라도 1차 냉각재 계통의 유동 안정성을 보장함을 알 수 있다.

  • PDF

Development of Large-area Plasma Sources for Solar Cell and Display Panel Device Manufacturing

  • 서상훈;이윤성;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.148-148
    • /
    • 2011
  • Recently, there have been many research activities to develop the large-area plasma source, which is able to generate the high-density plasma with relatively good uniformity, for the plasma processing in the thin-film solar cell and display panel industries. The large-area CCP sources have been applied to the PECVD process as well as the etching. Especially, the PECVD processes for the depositions of various films such as a-Si:H, ${\mu}c$-Si:H, Si3N4, and SiO2 take a significant portion of processes. In order to achieve higher deposition rate (DR), good uniformity in large-area reactor, and good film quality (low defect density, high film strength, etc.), the application of VHF (>40 MHz) CCP is indispensible. However, the electromagnetic wave effect in the VHF CCP becomes an issue to resolve for the achievement of good uniformity of plasma and film. Here, we propose a new electrode as part of a method to resolve the standing wave effect in the large-area VHF CCP. The electrode is split up a series of strip-type electrodes and the strip-type electrodes and the ground ones are arranged by turns. The standing wave effect in the longitudinal direction of the strip-type electrode is reduced by using the multi-feeding method of VHF power and the uniformity in the transverse direction of the electrodes is achieved by controlling the gas flow and the gap length between the powered electrodes and the substrate. Also, we provide the process results for the growths of the a-Si:H and the ${\mu}c$-Si:H films. The high DR (2.4 nm/s for a-Si:H film and 1.5 nm/s for the ${\mu}c$-Si:H film), the controllable crystallinity (~70%) for the ${\mu}c$-Si:H film, and the relatively good uniformity (1% for a-Si:H film and 7% for the ${\mu}c$-Si:H film) can be obtained at the high frequency of 40 MHz in the large-area discharge (280 mm${\times}$540 mm). Finally, we will discuss the issues in expanding the multi-electrode to the 8G class large-area plasma processing (2.2 m${\times}$2.4 m) and in improving the process efficiency.

  • PDF

GA 기반의 비선형 PID 제어기 설계 및 CSTR 프로세스에 응용 (GA-Based Design of a Nonlinear PID Controller and Application to a CSTR Process)

  • 이주연;소건백;이윤형;소명옥;진강규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.633-641
    • /
    • 2015
  • 선박, 발전소, 석유화학 등의 분야에서 운전되고 있는 많은 프로세스들은 강한 비선형성을 보일 뿐만 아니라 동시에 시변 특성도 가지고 있다. 이런 프로세스에 기존의 고정-파라미터 PID 제어기를 적용하면 성능이 나빠지고 경우에 따라서는 불안정해질 수도 있다. 따라서 본 연구에서는 복잡한 프로세스를 제어하기 위한 비선형 PID 제어기를 제안한다. 제안되는 제어기의 이득은 오차와 오차의 변화율의 비선형 함수로 기술되며, 사용자 파라미터들은 ITAE를 최소로 하는 관점에서 유전알고리즘으로 동조된다. 제안된 방법은 열분해반응 또는 촉매를 이용한 고분자합성에 널리 사용되는 연속 교반탱크반응기를 대상으로 시뮬레이션을 실시하며, 그 유효성을 보이기 위해 다른 두 비선형/적응 제어법과 비교한다.

Formation and Characteristics of the Fluorocarbonated SiOF Film by $O_2$/FTES-Helicon Plasma CVD Method

  • Kyoung-Suk Oh;Min-Sung Kang;Chi-Kyu Choi;Seok-Min Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.77-77
    • /
    • 1998
  • Present silicon dioxide (SiOz) 떠m as intennetal dielectridIMD) layers will result in high parasitic c capacitance and crosstalk interference in 비gh density devices. Low dielectric materials such as f f1uorina뼈 silicon oxide(SiOF) and f1uoropolymer IMD layers have been tried to s이ve this problem. I In the SiOF ftlm, as fluorine concentration increases the dielectric constant of t뼈 film decreases but i it becomes unstable and wa않r absorptivity increases. The dielectric constant above 3.0 is obtain어 i in these ftlms. Fluoropolymers such as polyte$\sigma$따luoroethylene(PTFE) are known as low dielectric c constant (>2.0) materials. However, their $\alpha$)Or thermal stability and low adhesive fa$\pi$e have h hindered 야1리ru뚱 as IMD ma따"ials. 1 The concept of a plasma processing a찌Jaratus with 비gh density plasma at low pressure has r received much attention for deposition because films made in these plasma reactors have many a advantages such as go여 film quality and gap filling profile. High ion flux with low ion energy in m the high density plasma make the low contamination and go어 $\sigma$'Oss피lked ftlm. Especially the h helicon plasma reactor have attractive features for ftlm deposition 야~au똥 of i앙 high density plasma p production compared with other conventional type plasma soun:es. I In this pa야Jr, we present the results on the low dielectric constant fluorocarbonated-SiOF film d밑JOsited on p-Si(loo) 5 inch silicon substrates with 00% of 0dFTES gas mixture and 20% of Ar g gas in a helicon plasma reactor. High density 띠asma is generated in the conventional helicon p plasma soun:e with Nagoya type ill antenna, 5-15 MHz and 1 kW RF power, 700 Gauss of m magnetic field, and 1.5 mTorr of pressure. The electron density and temperature of the 0dFTES d discharge are measUI벼 by Langmuir probe. The relative density of radicals are measured by optic허 e emission spe따'Oscopy(OES). Chemical bonding structure 3I피 atomic concentration 따'C characterized u using fourier transform infrared(FTIR) s야3띠"Oscopy and X -ray photonelectron spl:’따'Oscopy (XPS). D Dielectric constant is measured using a metal insulator semiconductor (MIS;AVO.4 $\mu$ m thick f fIlmlp-SD s$\sigma$ucture. A chemical stoichiome$\sigma$y of 야Ie fluorocarbina$textsc{k}$영-SiOF film 따~si야영 at room temperature, which t the flow rate of Oz and FTES gas is Isccm and 6sccm, res야~tvely, is form려 야Ie SiouFo.36Co.14. A d dielec$\sigma$ic constant of this fIlm is 2.8, but the s$\alpha$'!Cimen at annealed 5OOt: is obtain려 3.24, and the s stepcoverage in the 0.4 $\mu$ m and 0.5 $\mu$ m pattern 킹'C above 92% and 91% without void, res야~tively. res야~tively.

  • PDF

Simulation of reactivity-initiated accident transients on UO2-M5® fuel rods with ALCYONE V1.4 fuel performance code

  • Guenot-Delahaie, Isabelle;Sercombe, Jerome;Helfer, Thomas;Goldbronn, Patrick;Federici, Eric;Jolu, Thomas Le;Parrot, Aurore;Delafoy, Christine;Bernaudat, Christian
    • Nuclear Engineering and Technology
    • /
    • 제50권2호
    • /
    • pp.268-279
    • /
    • 2018
  • The ALCYONE multidimensional fuel performance code codeveloped by the CEA, EDF, and AREVA NP within the PLEIADES software environment models the behavior of fuel rods during irradiation in commercial pressurized water reactors (PWRs), power ramps in experimental reactors, or accidental conditions such as loss of coolant accidents or reactivity-initiated accidents (RIAs). As regards the latter case of transient in particular, ALCYONE is intended to predictively simulate the response of a fuel rod by taking account of mechanisms in a way that models the physics as closely as possible, encompassing all possible stages of the transient as well as various fuel/cladding material types and irradiation conditions of interest. On the way to complying with these objectives, ALCYONE development and validation shall include tests on $PWR-UO_2$ fuel rods with advanced claddings such as M5(R) under "low pressure-low temperature" or "high pressure-high temperature" water coolant conditions. This article first presents ALCYONE V1.4 RIA-related features and modeling. It especially focuses on recent developments dedicated on the one hand to nonsteady water heat and mass transport and on the other hand to the modeling of grain boundary cracking-induced fission gas release and swelling. This article then compares some simulations of RIA transients performed on $UO_2$-M5(R) fuel rods in flowing sodium or stagnant water coolant conditions to the relevant experimental results gained from tests performed in either the French CABRI or the Japanese NSRR nuclear transient reactor facilities. It shows in particular to what extent ALCYONE-starting from base irradiation conditions it itself computes-is currently able to handle both the first stage of the transient, namely the pellet-cladding mechanical interaction phase, and the second stage of the transient, should a boiling crisis occur. Areas of improvement are finally discussed with a view to simulating and analyzing further tests to be performed under prototypical PWR conditions within the CABRI International Program. M5(R) is a trademark or a registered trademark of AREVA NP in the USA or other countries.

환상이중원관에서 R-113의 비등열전달에 관한 연구 (A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube)

  • 김명환;김철환;오철;윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

바이오필터와 황-석회석을 이용한 마을하수 처리 공정 개발 (Development of Process for Village Scale Wastewater Treatment Using Biofilter and Sulfur-limestone)

  • 김태규
    • 한국농공학회논문집
    • /
    • 제49권2호
    • /
    • pp.75-86
    • /
    • 2007
  • This process which has a connection of biofilter and sulfur-limestone has been developed to treat organic substances including BOD, COD and SS etc. and to treat sulfur-limestone is for denitrification.. The whole process consists of chemical reaction tank, sedimentation tank, trickling filter, denitrification tank The trickling filter is equipped with a reactor filled with absorptive filter, and the sulfur denitrification tank is filled with sulfur-limestone mixed media. After setting up practical facilities whose capacity is 60 tons a day, we have observed the removal efficiencies of pollutants through 60 experiments during Summer and Winter seasons. The average concentration of polluted water was BOD for 3.6 mg/L, $COD_{Mn}$ for 11.3 mg/L, SS for 2.8 mg/L, T-N for 8.6 mg/L, and T-P for 0.8 mg/L, and the rate of treatment efficiencies 96.5%, 84.7%, 96.5%, 79.2%, and 80.8%, respectively was found through the experiments. The average treatment efficiency for BOD and $COD_{Mn}$ was 85.0% and 55.7%, respectively and the average removal efficiency for NH4+-N was 84.9% in the trickling filter. The removal efficiency in the denitrification tank is as follows; The removal rate of $NO_3^--N$ was as high as 93.2% within the compass of pH 6.3 to 7.3 through $16.8{\sim}37.0mg/L$ flown into $NO_3^--N$ and $0.1{\sim}8.3mg/L$ outflown. It had observed that this process has implemented highly efficient and advanced treatment without external carbon sources and internal recycle during its process. In conclusion, this process is suitable for a sewerage in a small village due to the merits of low power consumption and easy maintenance.

핵연료 노내조사시험설비 설치공사 완료 (The Construction Work Completion of the Fuel Test Loop)

  • 박국남;이정영;지대영;박수기;심봉식;안성호;김학노;이종민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.291-295
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL consists of In-Pile Test Section (IPS) and Out-Pile System (OPS). FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. Task Force Team was organized to do a construction systematically and the communication between members of the task force team was done through the CoP(community of Practice) notice board provided by the Institute. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. Without a sweet of the workers of the participating company of HEC(Hyundae Engineering Co, Ltd), HDEC(HyunDai Engineering & Construction Co. Ltd), equipment manufacturer, and the task force team, it is not possible to install the FTL facility within the planned shutdown period. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF