• 제목/요약/키워드: Advance Chamber

검색결과 42건 처리시간 0.016초

반건식 세정기의 산성가스 제거성능에 관한 실험적 연구 (An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber)

  • 양현모;김상수
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.589-598
    • /
    • 2000
  • A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

혼 입구에서의 음향 리액턴스에 근거한 자동차용 트럼펫 혼의 설계 연구 (A study on the design of a trumpet horn for automobiles based on acoustic reactance at the horn throat)

  • 이준수;김웅지;김대현;유동욱;문원규
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.39-48
    • /
    • 2024
  • 자동차용 경음기는 운전자 간의 의사소통 수단이자 보행자에게 사전에 경각심을 불러일으키는 부품으로서 안전상 중요한 역할을 한다. 유한 요소 방법과 전기 회로 모델을 활용한 자동차용 경음기의 모델링 연구와 혼의 음향학적 특성을 분석한 연구들이 수행되었으나, 트럼펫 혼의 작동 주파수 설계 방법에 대한 연구는 미비하다. 본 논문에서는 트럼펫 혼의 진동부가 결정되었을 때, 쉘의 음향 리액턴스에 따른 작동 주파수를 예측하는 설계 방법을 제시하고자 한다. 음향부에서는 지수 혼과 도파관이 결합된 혼에 대해 다루었고, 임피던스 튜브 실험을 통해 도파관의 입구 음향 리액턴스는 해석 결과와 유사함을 확인했다. COMSOL Multiphysics 유한 요소 수치 해석 모델을 이용하여 자동차용 경음기의 공진 주파수를 예측했고, 음압 실험을 통해 설계된 혼의 작동 주파수를 측정하여 설계 방법을 검증했다. 음압 실험은 홀더를 제외하고 DC 전압을 12 [V] 인가하여 반무향실 환경에서 측정한 결과, 설계 작동 주파수와 비교하여 수 [Hz] 내에서 정확하게 공진이 발생했다. 본 논문에서는 혼의 음향 리액턴스 관점에서 자동차용 트럼펫 혼의 설계 방법을 살펴보았고, 혼을 포함한 시스템을 설계할 때 유용하게 활용될 수 있을 것으로 기대한다.