• Title/Summary/Keyword: Adjustment screw

Search Result 14, Processing Time 0.025 seconds

A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve (유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구)

  • 이재구;김도태;김성동
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

Development of the Sorting Inspection System for Screw/Bolt Using a Slant Method (슬랜트방식을 이용한 스크류/볼트 선별검사시스템 개발)

  • Kim, Yong-Seok;Yang, Soon-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.698-704
    • /
    • 2010
  • The machine vision system has been widely applied at automatic inspection field of the industries. Especially, the machine vision system shows good performance at difficult inspection field by contact method. In this paper, the automatic system of a slant method to inspect screw/bolt shape using machine vision is developed. The inspection system uses pattern matching method that search similar degree of the lucidity, the average lucidity, length and angle of inspection set up area using a circular scan and a line scan method. Also the feeding method for inspection product is the slant method, and feed rate is controlled by the ramp angle adjustment. This inspection system is composed of a feeding device, a transfer device, vision systems, a lighting device and computer, and is composed the sorting discharge system of the inferior product. The performance test carried out the feeding speed, the shape correct degree and the sorting discharge speed according to the type of screw/bolt. This sorting inspection system showed a satisfied test results in whole inspection items. Presently, this sorting inspection system is being used in the manufacturing process of screw/bolt usefully.

Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses

  • Lee, Mi-Young;Heo, Seong-Joo;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.312-318
    • /
    • 2013
  • PURPOSE. The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. MATERIALS AND METHODS. A polyurethane resin block in which two implants were embedded served as a measurement model. Two groups of implant restorations utilized cement-retained design and internal surface of the first group was adjusted until premature contact between the restoration and the abutment completely disappeared. In the second group, only nodules detectable to the naked eye were removed. The third group employed screw-retained design and specimens were generated by computer-aided design/computer-aided manufacturing system (n=10). Four strain gauges were fixed on the measurement model mesially and distally to the implants. The strains developed in each strain gauge were recorded during fixation of specimens. To compare the difference among groups, repeated measures 2-factor analysis was performed at a level of significance of ${\alpha}$=.05. RESULTS. The absolute strain values were measured to analyze the magnitude of strain. The mean absolute strain value ranged from 29.53 to 412.94 ${\mu}m/m$ at the different strain gauge locations. According to the result of overall comparison, the cement-retained prosthesis groups exhibited significant difference. No significant difference was detected between milled screw-retained prostheses group and cement-retained prosthesis groups. CONCLUSION. Within the limitations of the study, it was concluded that the cement-retained designs do not always exhibit lower levels of stress than screw-retained designs. The internal adjustment of a cement-retained implant restoration is essential to achieve passive fit.

FIXED/REMOVABLE RECONSTRUCTION IN PARTIALLY EDENTULOUS PATIENT USING $Br{\aa}nrmark$ OSSEOINTEGRATED IMPLANTS AND TWO-PART I.T.I. IMPLANTS(BONEFIT) AS ABUTMENTS (Free-Standing $Br{\aa}nrmark$ Osseointegrated Implants와 Two-part I.T.I. Dental Implants(Benefit)를 이용한 하악 양측 대구치 결손 수복에 관한 임상적 연구(I))

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.151-162
    • /
    • 1993
  • The author installed $3.75mm\times10mm$ $Br{\aa}nrmark$ osseointegrated implants and $3.5mm\times8mm$ I.T.I. hollow screw implants(Benefit) as a free standing abutment to replace lower left and right molars of 44-year-old female patient. Form the foregoing procedure, the author obtained the following results. 1. Free-standing $Br{\aa}nrmark$ and I.T.I. Hollow screw implants(Benefit) could be used to replace molars effectively without reduction of adjacent natural teeth, 2. Rotation of occlusal gold screw of $Br{\aa}nrmark$ implants was observed under occlusal force. 3. Adjustment of height of I.T.I. abutments was necessary in the mandibular second molar because of the limited occlusal clearance. 4. Form the oral examination, patient comments, panoramic and periapical radiographs, there were no pain, gingival imflammation and mobility, but slight reduction of alveolar bone level was shown around both implant systems. 5. Patient comments were comfortable on both systems. but the patient complained about economic problem of $Br{\aa}nrmark$ system and long treatment treatment time of both systems.

  • PDF

Ergonomic evaluation of screw driver-using workstations: Psychophysical approach (스크류 드라이버를 사용하는 작업장의 인간공학적 평가:심리육체적 접근방법)

  • 박희석
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.51-62
    • /
    • 1996
  • This research utilized the psychophysical methodology, where secrw drivers are used, to determine the effects of i) the location and orientation of work objects, and ii) wearing gloves, on ratings of perceived exertion at various body parts. The validity of the psychophysical methodology in determining a preferred work pace was also studied. The subjects drove screws with a screw driver into thick wooden sheet at three vertical and three horizontal locations. They drove serews for 3 minutes at each location and assessed the condition using the psychophysical scale. The results showed that only the vertical location was a significant factor in determining the discomfort ratings. Driving screws at elbow height on the vertical surface and with the lower arm close to the body on the horizontal surface were the work locations with the smallest ratings of perceived discomfort. Wearing gloves had significant effects on reducing the pain of the hand. From the experiment in which a comfortable work pace was identified using 20 minute psychophysical adjustment, it was found that the psychophysical method is sensitive to workers perception of the physical stress when the upper limbs are employed. This was confirmend by the high correlation between the psychophysical results and EMG measurement.

  • PDF

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Modeling of Digital Servo System for Optical Pickup Tuner (광 픽업 조정기를 위한 디지털 서보 시스템의 모델링)

  • 곽한섭;백광렬
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • CD-ROM(Compact Disk-Read Only Memory) is very attractive storage media because it has much storage space but is small size and portable. Optical pickup, one of the most important parts for reading data on a CD-ROM, is not produced tuned up. For the use of goods, we must tune up the optical pickup by adjusting the screw for adjustment. First, we developed analog servo system for optical pickup tuners. For eliminating some problems in analog servo system, this paper designed the modeling of digital servo system for optical pickup tuner. Though the characteristics of optical pickup are changed, the digital servo system for optical pickup tuner can easily apply to all pickup, and can reduce the measurement error among the optical pickup tuners. For the purpose of confirming the designed digital servo system, we produced data that specify the disk vibration and the disk eccentricity, and simulated servo system with MATLAB.

  • PDF

Experiment Based Dynamic Analysis for High Accuracy Control of Feed System (이송계 고정도 제어를 위한 동특성 실험분석)

  • Kim, Shung-Hyun;Jeong, Jae-Hyun;Kim, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.729-737
    • /
    • 2009
  • This paper introduces the machine tools feed system, which can be optimized the control's performance through simulation and the adjustment of the mechanical components. One method simulates the frequency response of the speed-loop with the design value using the MATLAB application, so that all of the interpolation axis can be equal to the response bandwidth, resulting in a high accuracy rate. The other method sees the mechanical component being adjusted by analyzing the results of various experiments. Lastly, this client's program is able to change the parameters that are related to the FFD, as well as the parameters in the friction compensation of the OPEN-CNC.

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

  • Hur, Junseok W.;Park, Youn-Kwan;Kim, Bum-Joon;Moon, Hong-Joo;Kim, Joo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.368-373
    • /
    • 2016
  • Objective : Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. Methods : Patients who underwent plate-only open-door laminoplasty and had available postoperative computed tomography (CT) scans (80 patients with 270 laminae) were enrolled. Hinge status, hinge gutter location, open location, hinge width, number of screws used, operation level, and open angle were observed in the CT to determine radiographic outcome. Demographic data were collected as well. Radiographic and clinical parameters were analyzed using univariate and multivariate logistic regression analysis to determine the risk factors for HF. Results : Univariate logistic regression analysis results indicated poor initial hinge status, medially placed hinge gutter, double screw fixation on the elevated lamina, upper surgical level, and wide open angle as predictors for HF (p<0.05). Initial hinge status seemed to be the most powerful risk factor for HF (p=0.000) and thus was collinear with other variables. Therefore, multivariate logistic regression analysis was performed excluding initial hinge status, and the results indicated that medially placed hinge gutter, double screw fixation on the elevated lamina, and upper surgical level were risk factors for HF after adjustment for other confounding factors. Conclusion : To prevent HF and to draw a successful postoperative outcome after cervical laminoplasty, surgical and clinical precautions should be considered.

Design and Implementation of a Tunable Cavity Bandpass Filter (주파수 가변 캐비티 대역통과필터의 설계 및 구현)

  • Kang, Sanggee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.483-488
    • /
    • 2020
  • In recent years, the demand for wireless devices incorporating several wireless communication systems into one has been increasing in order to provide services that meet the diverse needs of consumers. Wireless devices consisting of various wireless communication systems require many frequency fixed filters. A frequency tunable filter can replace a number of frequency fixed filters in the wireless devices. If a frequency tunable filter is used in wireless systems, the system can be configured more efficiently. In this paper, a 3-pole frequency tunable BPF(bandpass filter) operating in the frequency band of 800 ~ 2400MHz is designed. In order to widen the operating frequency band, a tuning screw is designed to have a step and a linear motor is used to facilitate the adjustment of the tuning screw. The implemented frequency tunable BPF operates in the designed frequency range and has the maximum insertion loss of 2.82dB in the channel band and the minimum attenuation of 18.7dB at ± 50MHz frequency offset from the center frequency of the band.