• 제목/요약/키워드: Adiabatic Film Cooling Effectiveness

검색결과 16건 처리시간 0.02초

분사홀 형상과 분사각 변화가 터빈블레이드 선단 막냉각 특성에 미치는 영향 (Effects of Various Injection Hole Shapes and Injection Angles on the Characteristics of Turbine Blade Leading Edge Film Cooling)

  • 김윤제;권동구
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.933-943
    • /
    • 2001
  • Using a semi-circled blunt body model, the geometrical effects of injection hole on the turbine blade leading edge film cooling are investigated. The film cooling characteristics of two shaped holes (laterally- and streamwise-diffused holes) and three cylindrical holes with different lateral injection angles, 30°, 45°, 60°, respectively, are compared with those of cylindrical hole with no lateral injection angle experimentally and numerically. Kidney vortices, which decrease the adiabatic film cooling effectiveness, appear on downstream of the cylindrical hole with no lateral injection angle. At downstream of the two shaped holes have better film cooling characteristics than the cylindrical one. Instead of kidney vortices, single vortex appears on downstream of injection holes with lateral injection angle. The adiabatic film cooling effectiveness is symmetrically distributed along the lateral direction downstream of the cylindrical hole with no lateral injection angle. But, at downstream of the cylindrical holes with lateral injection angle, the distribution of adiabatic film cooling effectiveness in the lateral direction shows asymmetric nature and high adiabatic film cooling effectiveness regions are more widely distributed than those of the cylindrical hole with no lateral injection angle. As the blowing ratio increases, also, the effects of hole shapes and injection angles increase.

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(II) -분사비의 영향- (Film Cooling from Two Rows of Holes with Opposite Orientation Angles(II) -Blowing Ratio Effect-)

  • 안준;정인성;이준식
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1131-1139
    • /
    • 2001
  • Experimental results are presented, which describe the effect of blowing ratio on film cooling from two rows of holes with opposite orientation angles. The inclination angle is fixed at 35°, and the orientation angles are set to be 45°for the downstream row, and -45°for the upstream row. The studied blowing ratios are 0.5, 1.0 and 2.0. The boundary layer temperature distributions are measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions are measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux is evaluated from the adiabatic film cooling effectiveness and heat transfer coefficient data. The results show that the investigated geometry provides improved film cooling performance at the high blowing ratios of 1.0 and 2.0.

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향 (Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects)

  • 안준;정인성;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.113-118
    • /
    • 2000
  • Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

  • PDF

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(I) -배열의 영향- (Film Cooling from Two Rows of Holes with Opposite Orientation Angles(I) -Configuration Effect-)

  • 안준;정인성;이준식
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1122-1130
    • /
    • 2001
  • Film cooling performance from two rows of holes with opposite orientation angles is evaluated in terms of heat flux ratio. The film cooling hole has a fixed inclination angle of 35°and orientation angle of 45°for the downstream row and -45°for the upstream row. Four film cooling hole arrangements including inline and staggered configurations are investigated. The blowing ratio studied was 1.0. Boundary layer temperature distributions are measured to investigate injectant behaviors and mixing characteristics. Detailed distributions of the adiabatic film cooling effectiveness and the heat transfer coefficient are measured using TLC(Thermochromic Liquid Crystal). For the inline configuration, there forms a downwash flow at the downstream hole exit to make the injectant well attach to the wall, which gives high adiabatic film cooling effectiveness and heat transfer coefficient. The evaluation of heat flux ratio shows that the inline configuration gives better film cooling performance with the help of the downwash flow at the downstream hole exits.

사각홀에서 막냉각 효율 및 열전달계수의 측정 (Measurement of Film Cooling Effectiveness and Heat Transfer of Rectangular-Shaped Film Cooling Holes)

  • 이윤석;이동호
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.365-376
    • /
    • 2002
  • An experimental study has been conducted to measure the local film-cooling effectiveness and the heat transfer coefficient for a single row of rectangular-shaped holes. four different cooling hole shapes such ai a straight rectangular hole, a rectangular hole with laterally expanded exit, a circular hole and a two-dimensional slot are tested. A technique using thermochromic liquid crystals determine adiabatic film cooling effectiveness values and heat transfer coefficients on the test surface. Both film cooling effectiveness and heat transfer coefficient are measured for various blowing rates and compared with the results of the cylindrical ho1es and the two-dimensional slot. The flow patterns downstream of holes are calculated numerically using a cummercial package. The results show that the rectangular hopes provide better peformance than the cylindrical holes. For the rectangular holes with expanded exit, the penetration is reduced significantly, and the higher and more uniform cooling Peformance is obtained even at relatively high blowing rates.

Experimental Study of Film Cooling Behaviors at a Cylindrical Leading Edge

  • Kim S. M.;Kim Youn-J.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.81-84
    • /
    • 2002
  • Dispersion of coolant jets in a film cooling flow field is the result of a highly complex interaction between the film cooling jets and the mainstream. In order to investigate the effect of blowing ratios on the film cooling of turbine blade, cylindrical body model was used. Mainstream Reynolds number based on the cylinder diameter was $7.1\;\times\;10^4$. The free-stream turbulence intensity kept at $5.0\%$ by using turbulence grid. The effect of coolant flow rates was studied for blowing ratios of 0.9, 1.3 and 1.6, respectively. The temperature distribution of the cylindrical model surface is visualized by infrared thermography (IRT). Results show that the film-cooling performance may be significantly improved by controlling the blowing ratio. As blowing ratio increases, the adiabatic film cooling effectiveness is more broadly distributed and the area protected by coolant increases. The mass flow rate of the coolant through the first-row holes is less than that through the second-row holes due to the pressure variation around the cylinder surface.

  • PDF

Effect of Hole Shapes, Orientation And Hole Arrangements On Film Cooling Effectiveness

  • Jindal, Prakhar;Roy, A.K.;Sharma, R.P.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.341-351
    • /
    • 2016
  • In this present work, the effect of hole shapes, orientation and hole arrangements on film cooling effectiveness has been carried out. For this work a flat plate has been considered for the computational model. Computational analysis of film cooling effectiveness using different hole shapes with no streamwise inclination has been carried out. Initially, the model with an inclination of $30^{\circ}$ has been verified with the experimental data. The validation results are well in agreement with the results taken from literature. Five different hole shapes viz. Cylindrical, Elliptic, Triangular, Semi-Cylindrical and Semi-Elliptic have been compared and validated over a wide range of blowing ratios. The blowing ratios ranged from 0.67 to 1.67. Later, orientation of holes have also been varied along with the number of rows and hole arrangements in rows. The performance of film cooling scheme has been given in terms of centerline and laterally averaged adiabatic effectiveness. Semi-elliptic hole utilizes half of the mass flow as in other hole shapes and gives nominal values of effectiveness. The triangular hole geometry shows higher values of effectiveness than other hole geometries. But when compared on the basis of effectiveness and coolant mass consumption, Semi-elliptic hole came out to give best results.

Thermal Analysis of a Film Cooling System with Normal Injection Holes Using Experimental Data

  • Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee;Kim, Moon-Young
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.55-60
    • /
    • 2009
  • The present study investigated temperature and thermal stress distributions in a film cooling system with normal injection cooling flow. 3D-numerical simulations using the FEM commercial code ANSYS were conducted to calculate distributions of temperature and thermal stresses. In the simulations, the surface boundary conditions used the surface heat transfer coefficients and adiabatic wall temperature which were converted from the Sherwood numbers and impermeable wall effectiveness obtained from previous mass transfer experiments. As a result, the temperature gradients, in contrast to the adiabatic wall temperature, were generated by conduction between the hot and cold regions in the film cooling system. The gradient magnitudes were about 10~20K in the y-axis (spanwise) direction and about 50~60K in the x-axis (streamwise) direction. The high thermal stresses resulting from this temperature distribution appeared in the side regions of holes. These locations were similar to those of thermal cracks in actual gas turbines. Thus, this thermal analysis can apply to a thermal design of film cooling holes to prevent or reduce thermal stresses.

엇갈린 배열의 사각홀이 막냉각에 미치는 영향 (The Effects of Staggered Rows of Rectangular Shaped Holes on Film Cooling)

  • 김영봉;이동호;이윤석;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.304-314
    • /
    • 2004
  • An experimental study has been conducted to measure the temperature fields and the local film cooling effectiveness for two and three staggered rows of the rectangular shaped-holes with various blowing rates. The hydraulic diameter of rectangular-shaped hole is 10mm. To compare with the film cooling performance of rectangular-shaped hole, two kinds of circular holes are tested. One has the same hydraulic diameter as the rectangular hole and the other has the same cross sectional area. Also, rectangular holes with expanded exit with same inlet area as rectangular ones are tested. Temperature fields are measured using a thermocouple rake attached on three-axis traversing system. Adiabatic film cooling effectiveness on the surface are obtained based on experimental results of thermochromic liquid crystals. The film cooling effectiveness is measured for various blowing rates and compared with the results for the cylindrical holes. In case of 2 rows, the rectangular holes has better performance than circular holes due to its slot-like geometry. In case of 3 rows, the effecta of hole shape is not clear.

화염안정기 형상이 램제트 연소실에서의 슬롯 막냉각 특성에 미치는 영향 (Influence of Flame Holder on Film Cooling Effectiveness of Ramjet Combustor)

  • 이건우;송지운;조형희;황기영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.315-320
    • /
    • 2008
  • 본 연구에서는 화염 안정기 형상이 램제트 연소실에서의 단열 막냉각 효율에 미치는 영향에 대하여 실험을 수행하였다. 램제트 연소실 입구의 경사진 확장면의 끝에 화염안정기 형상을 설치하여 화염안정기에 의해 발생된 난류 유동이 다단 슬롯에 영향을 끼치도록 실험 장치를 구성하여, 화염안정기 형상을 탈부착 시키면서, 슬롯 출구 하류에서의 단열 막냉각 효율을 측정하였다. 화염 안정기를 설치하였을 경우 화염안정기에 의해 발생된 유동의 높은 전단력과 난류강도로 급격히 주유동과 혼합되어, 화염안정기가 설치되지 않은 경우에 비해 전체적으로 냉각 성능이 감소함을 결과를 통해 확인하였다.

  • PDF