• Title/Summary/Keyword: Adhesive strength

Search Result 1,545, Processing Time 0.031 seconds

Conservation of Paper Cultural Assets (지류문화재(紙類文化財)의 보존처리(保存處理))

  • Cheon, Ju-hyun;Kim, Sung-hee
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.21-27
    • /
    • 2001
  • In National Central Museum, we recently preserved paper cultural assets, such as ancient maps, books and antique documents etc, to prepare "A Dynamic World of External Relations in Goryeo & Joseon Dynasty". The paper cultural assets generally react sensitively to their environments; temperature, humidity, light and physical force acting. Biological damages, which are caused by microbe, contraction, swelling and damage from insects occurred. Wrinkles on relics, which are made my physical force, stains on relics which are due to moisture, weakening of adhesive strength and damages from insects were found during the recent preservation handling. Therefore we are trying to find out any damage, which could be occurred in paper cultural assets and introduce brief emergency operation to prevent the damages and develop the preservation handling.

A Study of Interface Layer on CdZnTe Radiation Sensor for Potable Isotope Identifier (이동형 핵종 분석 장치용 CZT 반도체 검출기의 완충전극에 대한 연구)

  • Cho, Yun Ho;Park, Se-Hwan;Kim, Yong Kyun;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2011
  • The electrical and mechanical properties of electrode for radiation detection are very important. In general, Au electrode and CZT crystal are combined to form ohmic contacts, and the best energy resolution is shown at the Au electrode. The metal contacts are fabricated by electroless deposition method, sputtering deposition method and thermal evaporation method. The electrode fabrication is easy with use of the thermal evaporation method, while an adhesive strength is weak. Thus interface materials such as Ag, Al and Ni were investigated to overcome defects generated by the this method. The thickness of the interface material between the Au electrode and the CZT crystal was 100 Angstroms, the Au electrode with thickness of 400 Angstroms was deposited. The Al+Au electrode is shown that the results of current-voltage and radiation response are similar to results of Au electrode.

Ion Beam-based Surface Modification of Polyimide Films for Adhesion Improvement with Deposited Metal Layer

  • Cho, Hwang-Woo;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.335-339
    • /
    • 2010
  • In this study, the surface of polyimide (PI) films was modified using ion implantation to enhance its adhesion to a deposited copper (Cu) layer. The surfaces of the PI films were implanted with 150 keV $Xe^+$ ions at fluences varying from $1{\times}10^{14}$ to $1{\time}10^{16}ions\;cm^{-2}$. The Cu layers were then deposited on the implanted PI. The surface properties of the implanted PI film were investigated based on the contact angle measurements, Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Furthermore, the adhesive strength between the deposited Cu layer and PI film was estimated through a scratch test using a nanoindenter. As a result, the surface environment of the PI film was changed by the ion implantation, which could have a significant effect on the adhesion between the deposited Cu layer and the PI.

Numerical investigation of continuous composite girders strengthened with CFRP

  • Samaaneh, Mohammad A.;Sharif, Alfarabi M.;Baluch, Mohammed H.;Azad, Abul K.
    • Steel and Composite Structures
    • /
    • v.21 no.6
    • /
    • pp.1307-1325
    • /
    • 2016
  • Nonlinear behavior of two-span, continuous composite steel-concrete girders strengthened with Carbon Fiber Reinforced Polymers (CFRP) bonded to the top of concrete slab over the negative moment region was evaluated using a non-linear Finite Element (FE) model in this paper. A three-dimensional FE model of continuous composite girder using commercial software ABAQUS simulated and validated with experimental results. The interfacial regions of the composite girder components were modeled using suitable interface elements. Validation of the proposed numerical model with experimental data confirmed the applicability of this model to predict the loading history, strain level for the different components and concrete-steel relative slip. The FE model captured the different modes of failure for the continuous composite girder either in the concrete slab or at the interfacial region between CFRP sheet and concrete slab. Through a parametric study, the thickness of CFRP sheet and shear connection required to develop full capacity of the continuous composite girder at negative moment zone have been investigated. The FE results showed that the proper thickness of CFRP sheet at negative moment region is a function of the adhesive strength and the positive moment capacity of the composite section. The shear connection required at the negative moment zone depends on CFRP sheet's tensile stress level at ultimate load.

Study of Pd Target Power Effects on Physical Characteristics of Pd-Doped Carbon Thin Films Using Dual Magnetron Sputtering Method (듀얼 마그네트론 스퍼터링 법으로 제조된 Pd-Doped Carbon 박막의 물리적 특성에서 Pd 타겟 전력의 영향에 대한 연구)

  • Choi, Young-Chul;Park, Yong Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.488-493
    • /
    • 2022
  • Generally, diamond-like carbon films (a-C:H, DLC) have been shown to have a low coefficient of friction, a high hardness and a low wear rate. Pd-doped C thin film was fabricated using a dual magnetron sputtering with two targets of graphite and palladium. Graphite target RF power was fixed and palladium target RF power was varied. The structural, physical, and surface properties of the deposited thin film were investigated, and the correlation among these properties was examined. The doping ratio of Pd increased as the RF power increased, and the surface roughness of the thin film decreased somewhat as the RF power increased. In addition, the hardness value of the thin film increased, and the adhesive strength was improved. It was confirmed that the value of the contact angle indicating the surface energy increases as the RF power increases. It was concluded that the increase in RF power contributed to the improvement of the physical properties of Pd-doped C thin film.

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

The Effect of Double-mixed Particle Size Distribution on the Properties of Waterborne Polyurethane Resin (이중혼합 입자 크기 분포 효과에 따른 수분산 폴리우레탄 수지의 특성 변화 연구)

  • Jo, Kyoung-Il;Ko, Jae-Wang;Kim, Il-Jin;Lee, Jin Hong;Lee, Seung Geol
    • Textile Coloration and Finishing
    • /
    • v.34 no.4
    • /
    • pp.261-271
    • /
    • 2022
  • Waterborne polyurethane(WPU) is greatly affected by its properties depending on the average particle size. In this study, by analyzing the characteristics of WPUs with different average particle sizes according to the DMPA content and we confirmed that the WPU-Ms have different properties from the physical properties of WPU by mixing two types of WPU with different particle sizes in the same volume. At this time, we mixed WPU at an ideal ratio of 7:3 through literature research. In the thermal characteristic analysis, it was confirmed that the thermal decomposition temperature decreased and Tg increased as the content of DMPA, which is the hard segment, increased. In addition, the average particle size of WPU decreased as DMPA increased, and physical properties and adhesive strength were improved due to increased interaction. When mixed with each other in a weight ratio of 7:3, it was observed that adhesion and mechanical properties were improved compared to only WPU.

Evaluation of the Adhesion Stability According to the Backfilling Area of the Tile back of the Bathroom of an Apartment House (공동주택 욕실의 타일배면 뒤채움 피착면적에 따른 부착안정성 평가)

  • Kim, Bum Soo;Song, Je Young;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.14-15
    • /
    • 2021
  • Recently, the size of tiles used for bathroom walls in apartment houses is gradually increasing in size. The problem is that when these large-sized tiles are attached by the sticking method, due to the nature of the method, there is a concern about the stability of the attachment to the part (pupil) where the tile and the adhesive are not attached. The problem is serious as it leads to lawsuits in the outbreak court. In addition, it is urgent to verify the adhesion stability of the sticking method because secondary damage occurs due to a safety accident caused by the falling of the tile. Ministry of Land, Infrastructure and Transport [Investigation of defects in apartment houses, calculation of repair cost and defect determination criteria] ① The tile adhesion strength is 0.39N/mm2 or more and ② It is specified to fill 80% or more of the base area of the tile backside, but this is currently trendy. It is considered that large-sized tiles need to be verified from multiple angles, and as part of that, we intend to verify the adhesion stability according to the area to be attached to large-sized tiles.

  • PDF

A comparative study on consolidants for bronze objects conservation (청동유물 보존처리에 사용되는 강화처리제의 특성 비교)

  • Cho, Hyun-Kyung;Cho, Nam-Chul
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.263-271
    • /
    • 2009
  • The purpose of metal artifacts conservation is recovering the original state of objects and preventing it from further corrosion. Four different consolidants are selected that are widely used for bronze objects conservation. This study found out the characteristics of thin film by various experiments and analysis for the bronze plates coated using each solutions. After a series of analysis, resin B and V showed good coating properties. However, the evaluation point suited to this purpose are adhesive strength, stability against yellowing and corrosion resistance. Therefore, resin B of four different consolidants could expect to get the most suitable consolidation effect for consolidation purpose.

Development of Anti-Fouling Film Using Polyurea for Offshore Wind Turbine Substructure (폴리우레아를 활용한 해상풍력 지지구조물 안티파울링 필름 개발)

  • Jin Hyuk Son;Myung Bo Kang;Kyung Kuk Jung;Woo Beom Han
    • Journal of Wind Energy
    • /
    • v.15 no.1
    • /
    • pp.82-90
    • /
    • 2024
  • Bio-fouling has positive aspects that are used as a fish resource, but there are also negative aspects such as corrosion of the surface of the support structure, aesthetics and work safety problems. A specimen was produced using a polyurea material with excellent anti-fouling and methodology, and contact angle, high water pressure, adhesion, and real sea area tests were performed. As a result of measuring the contact angle of the specimen with a 10 cm x 10 cm area of polyurea, There was found to be an average of 124.4 ° at nine points. No surface damage was found even above 5 Mpa when high water pressure was sprayed, and adhesive strength of 300LSE adhesives was confirmed between 22.84 and 23.04 Mpa with an adhesion test. During the 6-month real sea area test, it was confirmed that about 17.24 % of the polyurea film was less generated than the comparison group.