• Title/Summary/Keyword: Adhesion Measurement

Search Result 240, Processing Time 0.025 seconds

Structural Strength Analysis and Static Load Test of a Wheelset of Korean High Speed Rail for Measuring Whee/Rail Force (한국형 고속철도차량의 차륜/궤도 작용력 측정을 위한 윤축의 구조강도 해석 및 정하중 시험)

  • 전응식;함영삼;허현무;강부병
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.898-903
    • /
    • 2002
  • The railroad is a means of large transportation which has many talents such as a safety and a regularity. That is a results from various confidential performance tests and evaluations of the system. The railroad system consist of various subsystems - vehicle, power supply, signal, communications, track structures, operations, etc. Among them, as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more inportant in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of high speed rail, such as to treat a measuring wheelset, its finite element analysis, adhesion of strain gauges and static load test.

  • PDF

Finite Element Analysis and Static Load Test of a Wheelset of Gwangju EMU for Measuring Wheel/Rail Force (차륜/궤도 작용력 측정을 위한 광주전동차 윤축의 구조해석 및 정하중 시험)

  • Jeon Eung-Sik;Ham Young-Sam;Chung Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.762-767
    • /
    • 2003
  • The railroad is a means of large transportation which has many talents such as a safety and a regularity. That is a results from various confidential performance tests and evalutions of the system. The railroad system consist of various subsystems - vehicle, power spply, signal communications, track structures, operations, etc. Among them as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more important in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of Gwangiu EMU, such as to treat a measuring wheelset its finite element analysis, adhesion of strain gauges and static load test.

  • PDF

Evaluation of running safety for korean high speed railway vehicle (한국형 고속철도차량의 주행안전성 평가)

  • Ham Young-Sam;Hur Hyun-Moo
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.316-321
    • /
    • 2003
  • The railroad is a means of large transportation which has many talents such as a safety and a regularity. That is a results from various confidential performance tests and evaluations of the system. The railroad system consist of various subsystems - vehicle, power supply, signal, communications, track structures, operations, etc. Among them, as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more important in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of high speed rail, such as to treat a measuring wheelset, adhesion of strain gauges and static load test, running test result of main line.

  • PDF

Preparation and Properties Measurement of 2-hydroxyethyl methacrylate / Water-dispersed polyurethane composites

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1224-1229
    • /
    • 2018
  • In this study, 2-hedroxyethyl methacrylate (2-HEMA) was graft synthesized on water-dispersed polyurethane using polytetramethylene ether glycoll (PTMG), and then the film of resin was prepared and the physical properties of polyurethane resin were measured. The mechanical properties of the synthesized polyurethane resin were measured by using FT-IR, UTM, adhesion performance measuring instrument. As a result of tensile strength measurement, the tensile strength of HPUD4 with high 2-HEMA content was increased to $5.05kgf/mm^2$, the elongation was measured as 285% of the HPUD1 sample not containing 2-HEMA and adhesive strength of HPUD4 sample was measured at 9.1 sec to 635 psi.

Design of 3D printed chip for thrombus measurement and feasibility study for smoking effect (혈전 측정용 3D printed chip 설계 및 흡연의 영향 사전 연구)

  • Haebeen Kim;Eunseop Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.74-79
    • /
    • 2023
  • Thrombogenesis, which is the process of blood clot formation, can be initiated by platelet activation. Excessive formation of blood clot in the bloodstream can lead to thrombosis. Therefore, when dealing with patients with disseminated intravascular coagulation (DIC) or children, it is necessary to use small amounts of blood. Hence, it is important to develop methods for the rapid and accurate measurement of the platelet function using a small amount of blood. In this study, 3D printing technology was utilized to facilitate the production of micro channels. The amount of platelet adhesion in smokers and non-smokers was compared by repeatedly exposing the structure of the channel to adjust the number of blood injections and facilitate thrombosis attachment to simple stenosis structures.

Study on Heat-shield Property of Surface-treated Inorganic Oxide Particles (표면처리된 무기산화물 입자의 열차단 특성에 관한 연구)

  • Kim, Dong Ho;Kim, Gu Ni
    • Journal of Adhesion and Interface
    • /
    • v.14 no.1
    • /
    • pp.28-35
    • /
    • 2013
  • In this study, we produced heat-shield coating materials using surface-treated Ga-doped ZnO (GZO) and investigated the dispersity of particle, visible light transmittance, ultraviolet light cut off, infrared light cut-off, heat-shielding property by surface-treating compounds and treatment conditions. In the case of using IPA or acryl binder for heat-shield coating, the dispersity of inorganic oxide particles was poor but in the case of using surface-treated inorganic oxide particles by hybrid compound having urethane (urea) group, acryl group and silica, dispersity of particle, visible light transmittance and haze were improved. We used the measurement kit and sunlamp for measuring heat-shielding property and confirmed that the internal temperature of the measurement kit using heat-shield film was lower more than $4.8^{\circ}C$ in comparison with using PET film for itself.

THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES (점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향)

  • Lee, In-Bog;Son, Ho-Hyun;Kwon, Hyuk-Chun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

Role of Cel5H protein surface amino acids in binding with clay minerals and measurements of its forces

  • Renukaradhya K. Math;Nagakumar Bharatham;Palaksha K. Javaregowda;Han Dae Yun
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.17.1-17.10
    • /
    • 2021
  • Our previous study on the binding activity between Cel5H and clay minerals showed highest binding efficiency among other cellulase enzymes cloned. Here, based on previous studies, we hypothesized that the positive amino acids on the surface of Cel5H protein may play an important role in binding to clay surfaces. To examine this, protein sequences of Bacillus licheniformis Cel5H (BlCel5H) and Paenibacillus polymyxa Cel5A (PpCel5A) were analyzed and then selected amino acids were mutated. These mutated proteins were investigated for binding activity and force measurement via atomic force microscopy (AFM). A total of seven amino acids which are only present in BlCel5H but not in PpCel5A were selected for mutational studies and the positive residues which are present in both were omitted. Of the seven selected surface lysine residues, only three mutants K196A(M2), K54A(M3) and K157T(M4) showed 12%, 7% and 8% less clay mineral binding ability, respectively compared with wild-type. The probable reason why other mutants did not show altered binding efficiency might be due to relative location of amino acids on the protein surface. Meanwhile, measurement of adhesion forces on mica sheets showed a well-defined maximum at 69±19 pN for wild-type, 58±19 pN for M2, 53±19 pN for M3, and 49±19 pN for M4 proteins. Hence, our results demonstrated that relative location of surface amino acids of Cel5H protein especially positive charged amino acids are important in the process of clay mineral-protein binding interaction through electrostatic exchange of charges.

Improved cell adhesion to ion beam-irradiated biodegradable membranes (이온빔조사에 의한 생분해성 차폐막의 세포부착력 증진에 관한 연구)

  • Lee, Yong-Moo;Park, Yoon-Jeong;Lee, Seung-Jin;Ku, Young;Rhyu, In-Chul;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.601-611
    • /
    • 1998
  • Ion irradiation is a very promising tool to modify the chemical structure and physical properities of polymers. This study was aimed to evaluate the cellular adhesion to ion beam-irradiated surface of biodegradable poly-l-lactide(PLLA) membrane. The PLLA membrane samples were irradiated by using 35 KeV $Ar^+$ to fluence of $5{\times}10^{13}$, $5{\times}10^{14}$ and $5{\times}10^{15}\;ion/cm^2$. Water contact angles to control and each dose of ion beam-irradiated PLLA membranes were measured. Cultured fetal rat calvarial osteoblasts were seeded onto control and each dose of ion beam-irradiated PLLA membranes and cultured. After 24 hours, each PLLA membranes onto which osteoblasts attached were examined by scanning electron microscopy(SEM). Osteoblasts were removed from each PLLA membrane and then, the vitality and the number of cells were calibrated. Alkaline phosphatase of detached cells from each PLLA membranes were measured. Ion beam-irradiated PLLA membranes showed no significantly morphological change from control PLLA membranes. In the measurement of water contact angle to each membrane, the dose range of ion beam employed in this study reduced significantly contact angles. Among them, $5{\times}10^{14}\;ion/cm^2$ showed the least contact angle. The vitalities of osteoblastes detached from each membranes were confirmed by flow cytometer and well attached cells with their own morphology onto each membranes were observed by SEM. A very strong improvement of the cell adhesion and proliferation was observed for ion beam-irradiated surfaces of PLLA membranes. $5{\times}10^{15}\;ion/cm^2$ exhibited the most strong effect also in cellular adherence. ALPase activities also tended to increase in ion beam-irradiated membranes but statistical differences were not found. These results suggested that ion beam irradiation is an effective tool to improve the adhesion and spreading behaviour of the cells onto the biodegradable PLLA membranes for the promotion of membrane-tissue integration.

  • PDF

The Effects of Poloxamer/Sodium Alginate Mixture Barriers on Prevention of Post-Operative Peritoneal Adhesion in Dogs (개에서 Poloxamer / Sodium Alginate 혼합물의 복강 유착 방지 효과)

  • Kim, Ji-Hun;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.324-330
    • /
    • 2009
  • This study was performed to determine the effectiveness of poloxamer/sodium alginate mixture(PX/SA) barriers on prevention of post-operative peritoneal adhesion in dogs. Fifteen mongrel dogs were divided into three experimental groups: non-treated group, 2% Sodium Carboxymethylcellulose (SCMC) treated group and PX/SA treated group. In order to induce adhesions, the anti-mesenteric serosa of the ileum was exteriorized and then abraded in a standard manner by scraping with a scalpel blade to create homogeneous petechial hemorrhagic surface over a 1 ${\times}$ 1 cm area. Solution of SCMC was allowed to spread across the intraperitoneal organs through a catheter using a syringe. PX/SA was simply coated over the abraded tissues. On day before and day 1, 4, 7, and 14 after operation, venous blood specimens were collected for measurement of RBC, total WBC and fibrinogen. The adhesions were blindly assessed 3 weeks later by using a computerized tensiometer. The RBC, total WBC and fibrinogen values of three groups showed no statistical significances. The mean tensile strength(gram force, gf) of formed adhesions on day 21 after surgery was 173.05${\pm}$113.48 in the non-treated group, 111.42 ${\pm}$ 38.25 in the SCMC group, and 69.00 ${\pm}$ 45.07 in the PX/SA group. The tensile strength values for adhesion seperation in PX/SA group was lower than those in SCMC group(p < 0.05) and significantly lower than those in the non-treated group(p < 0.05). Our data suggested that PX/SA should be effective on reducing peritoneal adhesion formation in dogs compared with SCMC. PX/SA may be applicable to preventing post-operative intraperitoneal adhesion in dogs.