• Title/Summary/Keyword: Adhesion Evaluation

Search Result 378, Processing Time 0.029 seconds

Estimation of Insulation Life of PAI/Nano Silica Hybrid Coil by Accelerated Thermal Stress (가속된 열적 스트레스에 의한 PAI / Nano Silica 하이브리드 코일의 절연수명 추정)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.52-60
    • /
    • 2019
  • In this paper, four types of insulation coils were fabricated by adding various kinds of glycols to improve the flexibility and adhesion of insulating coils in varnish dispersed with PAI / Nano Silica_15wt%. The applied voltage and frequency were 1.5 kV / 20 kHz for accelerated life evaluation. Through the 6th temperature stress level, the cause of the insulation breakdown of the coil was ignored and only the breakdown time was measured. The Arrhenius model was chosen based on the theoretical relationship between chemical reaction rate and temperature for estimating the insulation life of the coil due to accelerated thermal stress. Three types of distributions (Weibull, Lognormal, Exponential) were selected as the relationship between thermal stress model and distribution. The average insulation lifetime was estimated under the temperature stress of four types of insulation coils through the relationship between one kind of model and three kinds of distributions.

A Study on Evaluation of Field Applicability of Flexible Waterproofing Material with High Adhesion Using Reclaimed Natural Latex (천연 라텍스 재생고무를 활용한 고점착형 시트 방수재의 현장 적용성 평가 연구)

  • Oh, Sangkeun;Jo, Ilkyu;Kim, Jinsung;Kim, Dongbum;Lee, Jongyong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • This study has been conducted in order to propose Eco-friendly and High functional waterproofing technology available for structure by verifying application and performance of water proofing material(s) in purpose of making effective use of reclaimed rubber. As s result of 12 months evaluation, stable performance for water pressure and lateral pressure of $0.3N/mm^2$ were confirmed. Also, as the time elapsed, the amount of water absorption and adhesion performance showed only a slight difference(+0.05g, $-0.1Nmm^2$) as well, which in turn confirmed that waterproofing performance remains stable. Studies show that it is expected to expand recycling technology of natural rubber by applying reclaimed rubber on construction waterproofing field, and to hold a technical superiority by using eco-friendly material in construction waterproofing market throughout active application of these types of research.

  • PDF

Evaluation For Adhesion in Tension of SBR Polymer Modified Concrete Tensile by Uniaxial Method (직접인장방법에 의한 SBR 폴리머 개질 콘크리트의 부착강도 특성 평가)

  • Yun, Kyong-Ku;Jang, Heung-Gyun;Lee, Nam-Ju;Lee, Seung-Jae;Hong, Chang-Woo
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.117-126
    • /
    • 2001
  • In this research, evaluation of adhesion in tension property of SBR-modified concrete to ordinary portland cement concrete was conducted with uniaxial direct tensile bond test which was proposed by Kuhlmann. A test set-up was fabricated in order to minimize the eccentric force by introducing a joint which might fully rotate. The main experimental variables were cement-latex ratios, surface preparations and moisture levels. The results obtained were as follows: The LMC specimen at 15% latex-cement ratio increased the adhesion in tension by range of 37% compared to that of conventional cement concrete. This might be due to latex film formed between cement paste and aggregate. The effects of surface preparation on bond of latex modified concrete to conventional concrete were significant at the conditions by sand paper and wire brush. A better bond could be achieved by rough surface rather than smooth. The saturated and surface dry (SSD) condition were considered to be the most appropriate moisture level followed by wet, finally by dry. Thus, a proper surface preparation and moisture level are quite necessity in order to obtain better bonding at LMC overlay.

  • PDF

Effect of reperfusion with leukocyte-depleted blood on the expression of myocardial vascular cell adhesion molecule-1 (VCAM-1) and myocardial function in isolated working heart perfusion model (단순 작업성 심관류 모델에서의 신생돈 심장의 보존 후 백혈구-제거 혈액을 이용한 재관류가 심근 VCAM-1 발현 및 심기능에 미치는 영향)

  • 이정렬;석철준;서정욱;한재진
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.213-220
    • /
    • 2000
  • Background: Adhesion of leukocytes to myocardium or vascular endothelium has been known as an importation initial step in the ischemia-reperfusion injury which may affect the cardiac function. Therefore, leukocyte-depleted reperfusion may inhibit ischemia-reperfusion induced functional and ultrastructural deterioration. In this study, we quantified the time-dependent expression of the vascular cell adhesion molecule-1(VCMA-1) on piglet myocardium and demonstrated its relation to functional recovery using isolated piglet heart perfusion model. Material and Method: Neonatal(1 to 3 day old) piglet heart was harvested with 4$^{\circ}C$ University of Wisconsin solution (UWS) and presrved in the same solution for 12 hours. Ex vivo model of an isolated working neonatal piglet heart perfusion consisting of membrane oxygenator and roller-pump was used (Fig. 1). Hearts were grouped into leukocyte-non-depleted (group A, n=8) and leukocyte-depleted group(group B, n=8). In group B, hearts were reperfused with leukocyte-depleted blood using a leukocyte filter (Sepacell R, Asahi Medical, Japan). Segments of right atrium were taken before and after 1, 2, 3, and 4 hours of reperfusion for the evaluation of expression of VCAM-1. The intensity of immunohistochyemical satining of the VCAM-1 on the myocardium were graded semiquantitatively (0 to 4). For the evaluation of myocardial stroke work indices were calculated as well at the same time-points. Result: Mean expressins of VCAM-1 on the myocardium at 0, 1, 2, 3, adn 4 hours of reperfusion were 0.63, 1.44, 1.64, 2.65, and 3.34 in group A, while 0.56, 1.40, 1.50, 1.88 and 2.14 in group B (Fig. 3). Mean stroke work indices at 0.5, 1, 2, 3, and 4 hours after reperfusion were 1.35$\times$104, 1.32$\times$104, 1.14$\times$104, 0.81$\times$104, 0.68$\times$104 erg/gm in group A, while 1.40$\times$104, 1.43$\times$104, 1.43$\times$104, 1.28$\times$104, and 1.12$\times$104 erg/em in group B(Fig. 4). Conclusion : In this study, we demonstrated that leukocyte-depletion attenuated the expression of VCAM-1 during reperfusion and the time-dependent functional deterioration of the myocardium was well correlated with the degree of VCAM-1 expression.

  • PDF

Evaluation of Environmental Stability and Durability of Cementitious Mixed Soil (시멘트계 혼합토의 환경안정성 및 내구성 평가)

  • Oh, Sewook;Bae, Wooseok;Kim, Hongseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2022
  • Using cement as a road subbase is economical, easily modified and supplemented and has excellent road pavement quality control. In addition, cement adheres well to sandy soils without adhesion, and it plays a role of permanently preserving adhesion in viscous soils with adhesion, so it can be widely applied as stable treatment with the advantages of increased strength, reduced compressibility. and improved durability. However, while cement is excellent in terms of strength for a road subbase, the material properties mean that it is difficult to maintain and reinforce when cracks or fractures occur due to dry shrinkage, and the pH increases in the ground due to hexavalent chromium eluting from cement. which can cause environmental problems such as groundwater contamination. Therefore, this study evaluates the usability of alternatives in the road base layer such as environmentally cementitious stabilizer and on-site soil generated from the site. We intend to reduce the environmental damage and evaluate the durability. To evaluate the applicability of the site, Environmental stability test and freeze-thaw test and wetting-drying test was conducted to evaluate the strength characteristics of alternative materials on the road through the limited performance evaluation of environmentally cementitious stabilizer. The test ranges were set at mixing ratios of 10%, 20%, and 30% and ages of three days, and 28 days old to evaluate the early strength and reference strength according to the mixing ratio of the environmentally cementitious stabilizer.

In vitro Cytotoxicity Evaluation of Polydimethylsiloxane as a Biosensor Coating Material (바이오센서 코팅용 Polydimethylsiloxane의 생체외 세포독성 평가)

  • Park, Subeom;Lee, Jonghwan;Na, Kyunga;Jung, Jaeyeon;Kim, Myungjin;Park, Sungjae;Hyun, Jinho
    • Journal of Adhesion and Interface
    • /
    • v.10 no.2
    • /
    • pp.77-83
    • /
    • 2009
  • PDMS was selected for a coating material of implantable biosensors and the cytotoxicity of extracts released from a polymer was evaluated using ISO 10993-5, Biological evaluation of medical devices-Part 5: Tests for in vitro cytotoxicity. Organo-tin was used as a positive control and a medium without serum was used as a negative control. Materials extract were prepared by incubating specimens in RPMI medium without serum ($125{\mu}L/cm^2$) for 24 h, 1 week and 6 weeks at $38^{\circ}C$. The evaluation of cytotoxicity was performed by two different methods : 1) seeding cells with extracts at the beginning 2) incubating extracts with cell sheets already formed on the plate. Both cell morphology and MTT numerical data were shown for the confirmation of cytotoxicity and cell spreading on the surface of PDMS.

  • PDF

A Study on the Economic Evaluation of Thermal Spray Methods for the Corrosion Protection of Steel (금속용사 방식공법의 경제성 평가에 관한 연구)

  • Jung Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.13-16
    • /
    • 2005
  • Generally, as corrosive protection processing of a steel structure, zinc galvanizing and heavy duty coating paint are applied. However, zinc galvanizing has the difficulty of restriction of a size, or on-site construction. Moreover, heavy duty coating paint has a problem with many administrative and maintenance expenses with short problem of adhesion, corrosion generating of a damage portion, and maintenance management cycle. In this study, a salt water spray test, CASS test, and the electrochemistry examination were carried out for the thermal metal spray method of construction for corrosive protection performance evaluation. Moreover, the corrosive protection life of a thermal metal spray method of construction was quantitatively calculated on the basis of this experiment. in consideration of LCC, the economical efficiency of a general corrosive protection method of construction and a thermal metal corrosive protection method of construction was compared. Consequently, although initial construction expense was estimated 16 to $30\%$ high, as for a thermal metal spray method of construction, it turns out that the administrative and maintenance expenses for 100 years became cheap 9.3 to 13 or more times.

  • PDF

Efficacy Evaluation of Tissue Inhibitor of Metalloproteinases-2 and Endostatin on Angiogenesis (Tissue Inhibitor of Metalloproteinases-2와 Endostatin의 혈관신생 제어 효능 평가)

  • Kim, Soo-Hyeon;Cho, Young-Rak;Yoon, Hyun-Jae;Ko, Hee-Young;Kim, Pyeung-Hyeun;Seo, Dong-Wan
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.488-493
    • /
    • 2010
  • Therapeutic manipulation of angiogenesis, the formation of new vascular sprouts from existing capillaries, is one of the promising strategies for treatment of human diseases such as cancer, arthritis, and cardiovascular disorder. In the present study, we examined the effects and molecular mechanism of tissue inhibitor of metalloproteinases-2 (TIMP-2) and endostatin on fibroblast growth factor-2 (FGF-2)-stimulated endothelial cell proliferation, migration and adhesion in vitro, and angiogenesis in vivo. TIMP-2 and endostatin showed potent anti-angiogenic activity in vitro and in vivo. These effects appear to be mediated through different angiogenic signaling pathways. Collectively, our findings demonstrate that TIMP-2 and endostatin strongly inhibit FGF-2-induced angiogenic responses, and the establishment of fast and reproducible evaluation system in vitro and in vivo for the development of anti-angiogenic biomaterials and therapeutics.

Single Carbon Fiber/Acid-Treated CNT-Epoxy Composites by Electro-Micromechanical Technique and Wettability Test for Dispersion and Self-Sensing (젖음성 시험과 전기-미세역학 시험법과 통한 단 카본섬유/산처리된 CNT-에폭시 나노복합재료의 분산과 자체-감지능)

  • Jang, Jung-Hoon;Wang, Zuo-Jia;GnidaKouong, Joel;Gu, Ga-Young;Park, Joung-Man;Lee, Woo-Il;Park, Jong-Kyoo
    • Journal of Adhesion and Interface
    • /
    • v.10 no.2
    • /
    • pp.90-97
    • /
    • 2009
  • Dispersion and self-sensing evaluation for single-carbon fiber reinforced in three different acid-treated CNT-epoxy nanocomposites were investigated by electro-micromechanical techniques and wettability tests. Self-sensing based on contact resistivity exhibited more noise for single carbon fiber/acid-treated CNT-epoxy composites than it did for untreated CNT. However, the apparent modulus was higher the acid treated case than the untreated case which is attributed to better stress transfer. The interfacial shear strength (IFSS) between carbon fibers and the CNT-epoxy was lower than that between carbon fiber and neat epoxy due to the increased viscosity associated with the addition of the CNT. The CNT-epoxy nanocomposite exhibited more hydrophobicity than did neat epoxy. Change in the thermodynamic work of adhesion was consistent with changes in the IFSS but disproportional to that of the apparent modulus. The optimum condition of acid treatment on the need can be obtained instead of the maximum condition.

  • PDF

Interfacial and Mechanical properties of Different Heat Treated Wood and Evaluation of Bonding Property between Stone and Wood for Rock Bed (열처리 조건에 따른 목재의 계면과 기계적 물성 및 돌침대용 석재/목재간 접착제에 따른 접착력 평가)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Choi, Jin-Yeong;Moon, Sun-Ok;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2015
  • Stone board for the rock bed was needed to reduce weight using thin thickness and reinforced materials. In this work, stone/wood board for rock bed was studied. Stone and wood were attached to reduce total weight of stone for rock bed. For reinforcing wood heat treatment method was used to change surface and mechanical properties. Mechanical strength of heat treated wood increased more than neat condition. The optimum heat treatment condition was set on $100^{\circ}C$ under tensile, flexural loads whereas surface energy was also obtained by contact angle measurement. Optimum adhesive condition was to get the maximum adhesion between stone and wood. Lap shear test was performed for stone/wood board with different adhesives such as amine type epoxy, polyurethane, chloro-rubber and vinyl chloride acetate type. Fracture surface of lap shear test was shown at wood fracture part on stone using amine type epoxy adhesive. It was found that for high adhesion between stone and wood the optimum adhesive was epoxy type for the rock bed.