• 제목/요약/키워드: Adhesion Coefficient

검색결과 188건 처리시간 0.024초

Reciprocating Wear Test of AISI 52100 Bearing Steel in h-BN-based Aqueous Lubricants

  • Gowtham Balasubramaniam;Dae-Hyun Cho
    • Tribology and Lubricants
    • /
    • 제39권6호
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, reciprocating wear tests are performed on AISI 52100 bearing steel to investigate its tribological behavior in a hexagonal boron nitride (h-BN) water solution. The h-BN-based aqueous lubricant is prepared using an atoxic procedure called ultrasonic sonication in pure water. Ball-on-flat reciprocating sliding experiments are conducted, where the ball is slewed on a fixed flat at 50-㎛ displacement. The lubricating behavior of h-BN is compared with that of deionized (DI) water. Results show that the friction coefficient is higher in h-BN testing than that in DI tests, but the results are equalized as the friction coefficient reaches a stable level. Scanning electron microscopic images reveal significant material loss in the center and mild abrasion on the edge of the wear scar in h-BN tests. However, these effects are minor in DI water situations. The results of energy-dispersive X-ray spectroscopy show that considerable oxidation occurs in the central zone of the wear scar in h-BN cases with strong adhesion and material removal. These findings reveal the importance of determining ideal circumstances that can tolerate material friction and wear.

내열 주강 디스크의 마찰특성: 열전도도 영향 (Tribological Properties of Heat-resistant Cast Steel Discs: Effect of Thermal Conductivity)

  • 김현승;이준상;조동현;강성웅;나태엽;장호
    • Tribology and Lubricants
    • /
    • 제30권1호
    • /
    • pp.29-35
    • /
    • 2014
  • The temperature-dependent tribological properties of brake discs for a train were examined in this study. The discs were produced using heat-resistant alloy steel, which showed different thermal conductivity after the heat treatments. A commercial brake friction material was used to evaluate the friction effectiveness, and the friction tests were carried out using a 1/5 scale dynamometer under various initial braking temperature conditions. The results showed that the tribological property of the disc was strongly affected by the heat treatment schedule. At low temperatures (below $250^{\circ}C$), the friction coefficient increased as a function of disc temperature, indicating that frictional heat increased the adhesion between the disc and pad. In addition, fade was observed at high temperatures (above $250^{\circ}C$); it was pronounced in the case of the disc with low thermal conductivity. The different fade resistances observed in the discs with different heat treatment schedules appear to be influenced by microstructural changes such as carbide redistribution occurring during the heat treatments, which affected the thermal conductivity.

복합 에멀젼계 마감재의 기초물성 평가에 관한 연구 (A Study on the Evaluation of Basic Properties of Composite Emulsion Finishes)

  • 류화성;신상헌;김득모;송성용
    • 한국건축시공학회지
    • /
    • 제20권1호
    • /
    • pp.35-41
    • /
    • 2020
  • 외단열 마감 공법에서 사용되는 얇은 바름재는 아크릴 에멀젼을 주 소재로 한 마감재이다. 본 연구에서는 실란 개질 아크릴 에멀젼과 실리카 분산아크릴 에멀젼을 치환하였을때 특성을 평가하였다. 실험결과, 실란 개질 아크릴 에멀젼은 인장강도 개선에는 큰 효과는 없었으나 부착강도, 물흡수계수, 온냉반복저항성의 성능 개선에 효과적인 것으로 나타났다. 실리카 분산 아크릴 에멀젼은 인장강도 개선에 효과적이며, 10%의 치환율에서는 부착강도, 물흡수계수, 온냉반복저항성의 성능 개선에 효과적인 것으로 나타났다. 이를 통해 아크릴 에멀젼의 성능을 향상할 수 있는 복합 에멀젼을 제조할 수 있는 것으로 판단되었다.

Muscle Strength and Biochemical Markers as Predictors of Depression in Hemodialysis Patients: A Cross-Sectional Study

  • Soudabeh Zare;Motahareh Hasani;M. Dulce Estevao;Rahim Tahmasebi;Leila Azadbakht;Farzad Shidfar;Javad Heshmati;Somayeh Ziaei
    • Clinical Nutrition Research
    • /
    • 제12권4호
    • /
    • pp.293-303
    • /
    • 2023
  • Patients with chronic renal failure, many of which treated with hemodialysis, present a high prevalence of impaired muscle strength which suggest that muscle mass parameters may be used as markers for changes in muscle in these patients. Measurement of handgrip strength (HGS) is a common, simple, and quick measure of muscle function an indicator of overall muscle strength which has been associated with physical activity and several anthropometric traits. Intercellular adhesion molecule-1 (ICAM-1) and insulin-like growth factor-1 (IGF-1) are biochemical markers associated with inflammatory processes which are a common consequence of dialysis. Additionally, hemodialysis patients frequently present signs of malnutrition and depression. This cross-sectional study aimed to evaluate if muscle and biochemical markers could be used to predict the risk of depression in hemodialysis patients. Several anthropometric parameters, nutrient intake, depression state and the serum levels of ICAM-1 and IGF-1 were determined and Pearson's correlation coefficient and/or Spearman's correlation coefficient were used to test the correlation between them. Our results do not show a correlation between HGF, IGF-1 and ICAM-1 with the depression status of the patients, but mid-arm muscle circumference (MAMC) was statistically and positively correlated with depression. Additionally, ICAM-1 levels were negatively correlated with HGS, MAMC, and IGF-1. Overall, the results of the present study suggest that HGS may be used as an indicator of cardiovascular diseases and MAMC may be a good predictor of the level of depression in hemodialysis patients, although further studies are required.

파이버 레이저를 이용한 치과용 임플란트 표면처리에 관한 연구 (A Study on the Surface Treatment of Dental Implant using a Fiber Laser)

  • 신호준;양윤석;황찬연;유영태
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.915-928
    • /
    • 2011
  • Titanium for dental implant application has the superior properties of biocompatibility, specific strength, and corrosion resistance. However, it is extremely difficult to find a suitable surface treatment method for sufficient osseointegration with biological tissue/bone cell and implant surface. Surface treatment technology using laser has been researched as the way to increase surface area of implant. In this study, to develop the surface treatment process with improved adhesion between implant and bone cell at the same time for superior biocompatibility, pulsed laser beam was overlapped continuously for scribed surface morphology and determination of friction coefficient. As the results, surface area and friction coefficient was increased over 2 times by the comparison with sand blasting, which is used for the conventional method. In this time, the optimal condition for laser beam power and beam irradiation speed was 13 watt and 50 mm/sec, respectively.

용사법에 의해 제조된 Al/SiC 복합재료의 마모거동 (2) - 작용하중의 영향 - (Wear Behavior of Al/SiC Composites Fabricated by Thermal Spray Process (2) - Effect of Applied Load on Wear Behavior -)

  • 이광진;김균택;김영식
    • Tribology and Lubricants
    • /
    • 제29권5호
    • /
    • pp.298-303
    • /
    • 2013
  • In this work, the effect of applied load on the wear behavior of Al/SiC composites was studied. Al/SiC composites were fabricated following the thermal spray process. Dry sliding wear tests were performed on these composites under four different applied loads, i.e., 5, 10, 15, and 20 N. The wear behaviors of the composites under these applied loads were investigated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Under applied loads of up to 15 N, the wear rates of Al/SiC composites decreased with an increase in the applied load because of the formation of an adhesion layer on the worn surface. However in the case of an applied load of 20 N, the wear rate was significantly high because the formation and fracture of the adhesion layer were repeated continuously. These results show that the wear behaviors of the tested composites are significantly influenced owing to the applied loads.

Tribological Characteristics of Magnetron Sputtered MoS$_2$ films in Various Atmospheric Conditions

  • Kim, Seock-Sam;Ahn, Chan-Wook;Kim, Tae-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1065-1071
    • /
    • 2002
  • The friction and wear behaviors of magnetron sputtered MoS$_2$ films were investigated through the use of a pin and disk type tester. The experiments were performed for two kinds of specimens (ground (Ra 0.5 $\mu\textrm{m}$) and polished (Ra 0.01 $\mu\textrm{m}$) substrates) under the following operating condifions : linear sliding velocities in the range of 22~66 mm/s (3 types), normal loads varying from 9.8~29.4 N(3 types) and atmospheric conditions of air, medium and high vacuum (3types). Silicon nitride pin was used as the lower specimen and magnetron sputtered MoS$_2$ on bearing steel disk was used as the upper specimen. The results showed that low friction property of the MoS$_2$ films could be identified in high vacuum and the specific wear rate in air was much higher than that in medium and high vacuum due to severe oxidation. It was found that the main wear mechanism in air was oxidation whereas in high vacuum accumulation of plastic flow and adhesion, were the main causes of wear.

Lead free, Low temperature sealing materials for soda lime glass substrates in Plasma Display Panel (PDP)

  • Lee, Heon-Seok;Hwang, Jong-Hee;Lim, Tae-Young;Kim, Yoon-Hee;Lee, Suk-Hwa;Kim, Il-Won;Lee, Jong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.373-376
    • /
    • 2008
  • New glass compositions for lead free, low temperature sealing glass frit was examined in $ZnO-V_2O_5-P_2O_5$ glass system which can be used sealing material for PDP to be made of soda lime glass substrates. Among many glass compositions, KFS-C glass showed low glass transition point (Tg) and good fluidity and adhesion characteristics when it was tested by flow button method at low temperature of $420^{\circ}C$. Its Tg was $317^{\circ}C$ and thermal expansion coefficient (CTE) was $70{\times}10^{-7}/K$. The glass frit was mixed with an organic vehicle to make a paste and it was dispensed and sealed with soda lime glass substrates at $420^{\circ}C$ for 10min. Sealed glass panels also showed good adhesion strength even sealed at low temperature of $420^{\circ}C$.

  • PDF

RF Plasma법으로 증착된 TiCN박막의 구조 및 기계적 거동에 관한 연구 (Structure & Mechanical Behavior of TiCN Thin Films by rf Plasma Deposition)

  • 백창현;박상렬;홍주화;위명용;강희재
    • 열처리공학회지
    • /
    • 제13권2호
    • /
    • pp.91-97
    • /
    • 2000
  • The structure and mechanical properties of TiN and TiCN thin films deposited on STD61 steel substrates by the RF-sputtering methods has been studied by using XPS, XRD, micro-hardness tester, scratch tester, and wear-resistance tester. XPS results showed that the TiCN thin film formed with chemical bonding state. The TiN thin films grew with (111) orientation having the lowest strain energy by compressive stress, whereas the TiCN thin films grew with both (111) and (200) orientation, but (200) orientation having the lowest surface energy becomes dominant as carbon contents increase. The pre-etching treatment of substrate did not affect on the preferred orientation of thin films, but it played an important role in improving mechanical properties of thin films such as the hardness, adhesion and wear- resistance. Especially, the TiCN thin films showed the superior wear resistances due to high hardness and low friction coefficient compared with TiN thin films.

  • PDF

리드 온 칩 패키징 기술을 이용하여 조립된 반도체 제품에서 패시베이션 박막의 TC 신뢰성에 영향을 미치는 요인들 (Factors to Influence Thermal-Cycling Reliability of Passivation Layers in Semiconductor Devices Utilizing Lead-on-Chip (LOC) Die Attach Technique)

  • 이성민;이성란
    • 한국재료학회지
    • /
    • 제19권5호
    • /
    • pp.288-292
    • /
    • 2009
  • This article shows various factors that influence the thermal-cycling reliability of semiconductor devices utilizing the lead-on-chip (LOC) die attach technique. This work details how the modification of LOC package design as well as the back-grinding and dicing process of semiconductor wafers affect passivation reliability. This work shows that the design of an adhesion tape rather than a plastic package body can play a more important role in determining the passivation reliability. This is due to the fact that the thermal-expansion coefficient of the tape is larger than that of the plastic package body. Present tests also indicate that the ceramic fillers embedded in the plastic package body for mechanical strengthening are not helpful for the improvement of the passivation reliability. Even though the fillers can reduce the thermal-expansion of the plastic package body, microscopic examinations show that they can cause direct damage to the passivation layer. Furthermore, experimental results also illustrate that sawing-induced chipping resulting from the separation of a semiconductor wafer into individual devices might develop into passivation cracks during thermal-cycling. Thus, the proper design of the adhesion tape and the prevention of the sawing-induced chipping should be considered to enhance the passivation reliability in the semiconductor devices using the LOC die attach technique.