• 제목/요약/키워드: Additional resistance

검색결과 566건 처리시간 0.025초

Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

  • Kim, Sang-Hyo;Park, Se-Jun;Heo, Won-Ho;Jung, Chi-Young
    • Steel and Composite Structures
    • /
    • 제18권2호
    • /
    • pp.497-517
    • /
    • 2015
  • This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

라텍스 혼입에 따른 LMC의 동결융해 저항특성평가 (Freezing and Thawing Resistance of Latex Modified Concrete with Latex Content)

  • 이주형;정원경;김동호;이봉학;원치문;이정호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.497-502
    • /
    • 2000
  • This study was performed to change the latex content for properties of freezing-thawing resistance. When styrene-butadiene latex is added to portland cement, aggregate and water, a concrete with the color, consistency and workability of ordinary conventional concrete results, but with 20% to 35% less water. When cured, the concrete consists of hydrated cement and aggregate interconnected by a film of latex particles. In general, increasing the amount of latex will produce concrete with increased tensile and flexural strength and lower modulus of elasticity. Air entrainment has been used in conventional concrete for the past 50 years to impart freeze-thaw resistance. Latex modified concrete does not need additional air entrainment for freeze-thaw resistance provided adequate cure occurs.

  • PDF

분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상 (Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling)

  • 박주생;김세종;이상준
    • 한국가구학회지
    • /
    • 제24권4호
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

온도에 따른 저항 변화를 보상한 전압 측정 방법 (Compensation of Resistance Variation due to Temperature in Voltage Measurement System)

  • 민상준;김진성
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1174-1177
    • /
    • 2012
  • In voltage measurement by using voltage divider with series resistors, error is generated caused by the variation of resistance. In order to reduce these errors, the hardware cost tends to increase in the previous works. In the proposed method, three resistors are used for the voltage divider of which the organization is adjusted by using switches. Three voltages are measured and the ratio of resistance is calculated based on the measured voltages. Since the resistance ratio is calculated by measuring voltages and additional hardware cost is minimal, the voltage can be measured with high accuracy and low cost. Experimental results show that the mean absolute error is 12.1 mV when the input voltage ranges from 5 V to 50 V.

도서순회 해상소각 바지선의 적정 스케그 형상및 크기에 관한 연구 (A study on the appropriate shape and size of skeg for the incinerator mounted circular barge)

  • 이귀주;이건철
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.100-106
    • /
    • 1997
  • Despite various devices have been developed and applied to stabilize the yaw motion, the superiority of twin skeg over other equi-functioned appendages has been recognized so far. In many cases, these skegs were installed with insufficient study and analysis for design, and this leads to the worse performance of their resistance and course keeping than required. Experimental studies on the effect of various kinds of anti-yawing skegs to the course keeping stability and on the additional resistance caused by them were carried out in the circulating water channel(CWC) at Chosun University(CU). Course keeping stability tests for four different size of skegs, resistance tests for three different shapes of skeg(including deformed skegs) were performed systematically. And the effect of angle of skegs on resistance was studied at the final stage.

  • PDF

후열처리에 의한 알루미늄 산화층의 특성 향상 (Enhanced Properties of Aluminum Oxide Layers with Post Heat Treatment)

  • 전윤남;김상준;박지현;정나겸
    • 한국표면공학회지
    • /
    • 제52권5호
    • /
    • pp.275-281
    • /
    • 2019
  • Anodization is widely used to enhance the properties of aluminum, such as hardness, electric resistance, abrasion resistance, corrosion resistance etc. But these properties can be enhanced with additional process. According to the partial crystallization of oxide layer with post heat treatment, enhanced hardness can be expected with partial crystallization. In this study, post heat treatments were applied to the anodized aluminum alloys of Al6061 to achieve the partial crystallization, and crystallizations were evaluated with the reduced breakdown voltages. Interestingly, remarkable enhanced hardness (21~29%), abrasion resistance (26~62%), and reduced breakdown voltage (24~44%) were observed for the sulfuric acid anodized samples when we annealed the anodized samples with 1hour post heat treatment at $360^{\circ}C$. For the Al5052 alloys, a lot of cracks were observed when we applied the post heat treatment.

TLM pattern을 사용한 Cr/Ag 및 Ni 전극에 따른 접합 저항 연구 (Study of contact resistance using the transmission line method (TLM) pattern for metal of electrode (Cr/Ag & Ni))

  • 황민영;구기모;구선우;오규진;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.349-349
    • /
    • 2010
  • Great performance of many semiconductor devices requirs the use of low-resistance ohmic contact. Typically, transmission line method (TLM) patterns are used to measure the specific contact resistance between silicon and metal. In this works, we investigate contact resistance for metal dependent (Cr/Ag, Ni) using TLM pattern based on silicon-on-insulator (SOI) wafer. The electrode with Ni linearly increases contact resistance as the pattern distance increase from $15{\mu}m$ to $75{\mu}m$ in accumulation part, but non-linearly increase in inversion part. In additional, the electrode with Cr/Ag linearly increases contact resistance as the pattern distance increase from $15{\mu}m$ to $75{\mu}m$ in inversion part, but non-linearly increase in accumulation part.

  • PDF

국내 피복 철골기둥의 내화 성능 분석 및 평가 (An Analysis and Evaluation of Fire Resistance Performance for the Protected Steel Columns in Korea)

  • 신태송
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.27-35
    • /
    • 2009
  • 주요 철골구조체는 일정한 시간동안 내화성능을 발휘하기 위한 내화조치를 필요로 한다. 본 연구는 철골기둥의 내화피복 국내인정 제품의 내화성능을 분석 평가함을 목적으로 한다. 대상제품은 보드피복과 뿜칠피복 두 종류의 제품을 대상으로 하여 샘플연구를 하였다. 국내기준과 유럽기준에 기초하여 제품의 내화성능을 분석하였다. 또한 국내기준을 유럽기준의 성능설계관점에서 분석 고찰하였다. 온도적 측면에서 국내기준의 내화성능은 일반적으로 안전하다고 사료되지만, 재료의 물성치 자료확충, 강재온도 산정방법, 프로필계수, 화재시 내력검증 등의 특성을 반영할 필요가 있다고 사료된다.

쐐기형 쏘일 네일의 인발 거동 특성 (Pullout Resistance Characteristics of the Wedge-shaped Soil Nail)

  • 김범주;이용준;윤용수;정민규;윤지남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1079-1083
    • /
    • 2009
  • In this study, the pullout resistance characteristic of a wedge-shaped soil nail, made by attaching small steel sticks to the tip of a nail in a wedge shape, was investigated. It was developed to improve the overall pullout resistance capacity of the existing soil nail system, composed of nail and grout, by making the wedge provide additional pullout resistance. In order to evaluate the pullout resistance of the wedge shape-soil nail, field pullout tests were conducted, and the results were compared with those for the existing soil nail without the wedge. The field test results showed that the pullout resistance capacity of the wedge-shaped soil nail was 50% larger than that of the existing soil nail without the wedge.

  • PDF

Effect of Additional Ag Layer on Corrosion Protection of Cu-Electrodeposited AZ31 Mg Alloy

  • Phuong, Nguyen Van;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.97-97
    • /
    • 2017
  • This study investigated the corrosion protection by electrodeposited copper layer on AZ31 Mg alloy with and without additional silver layer by immersion test, salt spray test, OCP transient and potentiodynamic polarization experiment. The single electrodeposited Cu layer on AZ31 Mg alloy showed a nodular structure with many imperfections of crevices between the nodules, which resulted in the fast initiation of pitting corrosion within first few hours of immersion. Double-layer coating of Cu and outer Ag layer slightly increased the initiation time for pitting corrosion. Triple-layer coatings of Cu/Ag/Cu exhibited the most efficient corrosion protection of AZ31 Mg alloy, compared to the single- and double-layer coatings. Surface morphology of the outer Cu layer in the triple-layer was changed from the nodular structure to fine particle structure with no crevices due to the presence of an additional Ag layer. Thus, the improved corrosion resistance of AZ31 Mg alloy by electrodeposited Cu/Ag or Cu/Ag/Cu layers is readily ascribed to the decreased number of imperfections in the electrodeposited layers due to the additional silver layer. It is concluded that the additional silver layer provides many nucleation sites for the second Cu plating, resulting in the formation of finer and denser structure than the first Cu electrodeposit.

  • PDF