• Title/Summary/Keyword: Additional gases

Search Result 80, Processing Time 0.024 seconds

Effect of Adding Hydrocarbon Gases for Reduction of NOx and SOx Using PPCP (탄화수소 가스 첨가가 PPCP 장치에 의한 NOx 및 SOx 저감에 미치는 영향)

  • 김홍석;강형수;정태용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.73-80
    • /
    • 1999
  • To decrease NOx and SOx using PPCP(Pulse-induced Plasma Chemical Process). This study is tried to obtain the relation and the basic data under the various conditions such the initial concentrations of NOx and SOx. The additional amount of hydrocarbon gases. The concentration of oxygen and input power etc. Especially, this study is focused on the effects of the additional hydrocarbon gases on the decrease of NOx and SOx.

  • PDF

Effect of Ambient Gas to Growth of SiO2 Nanowires by Vapor Evaporation Method (기상휘발법에 의한 이산화규소 나노와이어의 성장에 미치는 가스의 영향)

  • Rho Dae-Ho;Kim Jae-Soo;Byun Dong-Jin;Lee Jae-Hoon;Yang Jae-Woong;Kim Na-Ri
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.323-333
    • /
    • 2005
  • Effects of gases to growth of $SiO_2$ nanowires were characterized. $N_2$, Ar, and $O_2$ gas's effect were determined. $SiO_2$ nanowires growth scheme was varied by kind and flow rates of gases because of amounts of $O_2$. Flow rates of gases and kind of substrates affected nanowires' diameters, lengths and morphologies of grown nano wires. With increasing flow rates of gases, nanowire's diameter increased because of additional VS and SLS reactions. By TEM characterization, We knows that, grown $SiO_2$ nanowires on Si substrate showed two shell structures. These shapes of nanowires were formed by reaction of additional SLS growth. Grown $SiO_2$ nanowires showed blue luminescence by PL characterization These Blue luminescence was due to quantum confinement effect and oxygen vacancies in the nanowires.

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.

Characteristics of Energy Consumption for a Household Refrigerator under Influence of Non-condensable Gases (가정용 냉장고의 불응축 가스량에 따른 소비 전력 특성)

  • Kim, Doo-Hyun;Hwang, Yu-Jin;Park, Jae-Hong;Chung, Seong-Ir;Jeong, Young-Man;Ku, Bon-Cheol;Lee, Jae-Keun;Ahn, Young-Chull;Bang, Sun-Wook;Kim, Seok-Ro
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.381-387
    • /
    • 2008
  • The presence of non-condensable gases as an additional thermal resistance inside a refrigerating circuit has been found for a general refrigerator, The effect of non-condensable gases was varied by controlling the injection amount of dry air into the refrigerating circuit to increase a thermal resistance. Energy consumption tests for the refrigerator were conducted under the various amounts of non-condensable gases. The tested refrigerating circuit was the household refrigerator. As the molar fraction of non-condensable gases was increased from 0% to 1.46%, the amount of energy consumption was found to increase up to 25%. The increase of the amount of non-condensable gases in refrigerating circuit was found to result in increasing the condensation temperature at the condenser and decreasing the evaporation temperature at the evaporator, which were presumably caused by the low specific heat and increased partial pressure of non-condensable gas.

The Effects of Additional Gases(C,H,O) on Adhesive strength Ti$_{x}$N Films Prepared by the DC Magetron Suttering Method (DC Magetron Suttering법으로 제작한 Ti$_{x}$N 박막의 밀착력에 미치는 첨가원소(C,H,O))

  • 김학동;조성식
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.3
    • /
    • pp.142-150
    • /
    • 1998
  • Stainless steel is being used widely for various purposes due to its good corrosion resistance. There has been much research to produce colored stainless steel by several methods such as anodizing and ion plating. In this experiment, we coated TiN(C,O,H)films SUS304 substraate with the DC magnetron spttering system made by Leybold Heraeus and studied the interlater structure and abhesive strength of the films as a function of additional gases, acetylene, hydrogen and oxygen. When the acetylene gas was added into the chamber, the specimen with the interlayer phase had good adhesion due to the toughness of the $\gamma'-Fe_4N$ plase induced from a solid solution of carbon atoms, while low adhesion appeared on the specimen of the non interlayer phase. The formation of the interlayer phase($\gamma'-Fe_4N$) was due to hydrogen embrittlement and internal stress induced by $\gamma'-Fe_4N$ formation in the interlayer. We could fine the interlayer phase ($\gamma'-Fe_4N$) at the interface between the film and the substrate of the TEM image when $\gamma'-Fe_4N$ was detected by the X-ray duffraction metheod.

  • PDF

A Study on Effect of Thermal Decomposition Products of Coal on Anodic Reactions in Direct Carbon Fuel Cell (석탄 열분해 생성물이 직접탄소연료전지에서 애노드 반응에 미치는 영향에 대한 연구)

  • Rhie, Young Hoon;Eom, Seong Yong;Ahn, Seong Yool;Choi, Gyung Min;Kim, Duck Jool
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.5
    • /
    • pp.413-420
    • /
    • 2013
  • Effect of inherent volatile matters in fuels on electrochemical reactions of anode was investigated for a single direct carbon fuel cell (DCFC). Raw coals used as power source in the DCFC release light gases into the atmosphere under the operating temperature of DCFC ($700^{\circ}C$) by thermal decomposition and only char remained. These exhausted gases change the gas composition around anode and affect the electrochemical oxidation reaction of system. To investigate the effect of produced gases, comparative study was conducted between Indonesian sub-bituminous coal and its char obtained through thermal treatment, carbonizing. Maximum power density of raw coal ($52mW/cm^2$) was appeared higher than that of char ($37mW/cm^2$) because the gases produced from the raw coal during thermal decomposition gave additional positive results to electrochemical reaction of the system. The produced gases from coals were analyzed using TGA and FT-IR. The influence of volatile matters on anodic electrolyteelectrode interface was observed by the equivalent circuit induced from fitting of impedance spectroscopy data.

Effect of additional gases on the Color of TixN Coated Film (TixN Coating층의 색상에 미치는 첨가원소의 영향)

  • 김학동;조성석
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.127-134
    • /
    • 1998
  • Stainless steel is being used widely for various purposes due to its good corrosion resistance. There has been much research to produce a colored and corrosion-resistant stainless steel by several methods to use in decorating. In this experiment, we coated TiN(C,O,H)films on the SUS304 substrates with the DC magnetron sputtering system and then studied the texture and color of the films as a function of additional gases being inserted into the system. A (220) texture of TixN film changed to (200) by the addition of either hydrogen or the acetylene and changed further to (111) with an increase of the additional acetylene content. The addition of oxygen gas changed from the texture(220) to (111) to (200). The color of the TixN film changed from gold to gray to green with the increase of the content by the addition of oxygen gas, while it changed to pink and finally to gray with the increased of the content by the addition of acetylene gas. Reflectance increased in the region of short wavelength by the addition of hydrogen, but decreased with the increase of the oxygen and the acetylene content.

  • PDF

Comparison between CFD analysis and experiments according to various PEMFC flow-field designs (유로 형상 변화에 따른 CFD 해석 결과와 PEM 연료전지 성능 비교)

  • Lee, Kang-In;Park, Min-Soo;Lee, Se-Won;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.572-575
    • /
    • 2008
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in four kinds of flow-field designs without additional measurement equipment, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, the performance values of PEMFC according to the flow-field configurations were measured via a single cell test. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. So, the single serpentine configuration gave the highest performance. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

  • PDF

Analysis for the Coolability of the Reactor Cavity in a Korean 1000 MWe PWR Using MELCOR 1.8.3 Computer Code

  • Lee, Byung-Chul;Kim, Ju-Yeul;Chung, Chang-Hyun;Park, Soo-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.669-674
    • /
    • 1996
  • The analysis for the coolability of the reactor cavity in typical Korean 1000 MWe Nuclear Unit under severe accidents is performed using MELCOR 1.8.3 code. The key parameters molten core-concrete interaction(MCCI) such as melt temperature, concrete ablation history and gas generation are investigated. Total twenty cases are selected according to ejected debris fraction and coolant mass, The ablation rate of concrete decreases as mass of the melt decreases and coolant mass increases. Heat loss from molten pool to coolant is comparable to total decay heat, so concrete ablation is delayed until water is absent and crust begins to remove. Also, overpressurization due to non-condensible gases generated during corium and concrete interacts can cause to additional risk of containment failure. It is concluded that flooded reactor cavity condition is very important to minimize the cavity ablation and pressure load by non-condensible gases on containment.

  • PDF

An Establishment of Greenhouse Gas Information System using Excel Spreadsheets (엑셀 스프레드시트를 활용한 온실가스 정보시스템 구축)

  • Lee, Hae-Jung;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • Climate change is the biggest environmental issue of our times. A variety of activities to reduce greenhouse gas emissions have been in progress to observe the Kyoto Protocol. Especially, the Energy Target Scheme is created to reduce greenhouse emission with the supervision of Korean government. This includes Green-house Gas Information Systems to promote activities in the private sector to reduce green-house gas emissions, to cut a cost of energy use, and to reduce GHG emissions. Also, the system has calculated the amount of greenhouse gases. Without any additional investment, 2.75% savings are increased over the previous year. In service sector, a cooperation of customers and employees is necessary. A reduction of GHG emissions requires a proper service organization, considering an amount of investment and payback period. Without any additional investment or replacement, employees can save energy easily turning off ventilation systems an hour before employees' departure, installing timers to turn off water purifiers and vending machines after some period of no use. The Green-house Gas Information System is similar to that of Environmental Management System. However, the Excel is the best program to calculate an amount of green-house gas emissions, and to assess for a reduced amount of GHG emissions. A goal of this research is to propose a practical method in the private sector to calculate an amount of green-house gases. The Green-house gas Information System based on Excel spreadsheet gives standards for good evaluation. The greenhouse gas information system establishes and executes the policies and objectives related to greenhouse gas emissions Similar to ISO 14001 environment management system structures, the advantages of using simplified Excel Sheet for calculating GHG emissions and reducing GHG emissions are easy to access.