• Title/Summary/Keyword: Additional Plate

Search Result 381, Processing Time 0.026 seconds

Effect of Changes in Condition of Ammonia Gas Addition on the Surface Layer Microstructure and Porosity during Austenitic Nitriding of Low Carbon Steels (저 탄소강의 오스테나이트 질화 시 암모니아 가스첨가 조건변화가 표면층 조직 및 기공변화에 미치는 영향)

  • Lee, Jewon;Roh, Y.S.;Sung, J.H.;Lim, S.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.5
    • /
    • pp.201-211
    • /
    • 2019
  • Low carbon steel (S20C steel) and SPCC steel sheet have been austenitic nitrided at $700^{\circ}C$ in a closed pit type furnace by changing the flow rate of ammonia gas and heat treating time. When the flow rate of ammonia gas was low, the concentration of residual ammonia appeared low and the hardness value of transformed surface layer was high. The depth of the surface layer, however, was shallow. With increasing the concentration of residual ammonia by raising up the ammonia gas flow, both the depth of the surface layer and the pore depth increased, while the maximum hardness of the surface layer decreased. By introducing a large amount of ammonia gas in a short time, a deep surface layer with minimal pores on the outermost surface was obtained. In this experiment, while maintaining 10~12% of residual ammonia, the flow rate of inlet ammonia gas, 7 liter/min, was introduced at $700^{\circ}C$ for 1 hour. In this condition, the thickness of the surface layer without pores appeared about $60{\mu}m$ in S20C steel and $30{\mu}m$ in SPCC steel plate. Injecting additional methane gas (carburizing gas) to this condition played a deteriorating effect due to promoting the formation of vertical pores in the surface layer. For $1^{st}$ transformed surface layer for S20C steel, maintaining 10~12% residual ammonia condition via austenitic nitriding process resulted in ${\varepsilon}$ phase with relatively high nitrogen concentration (just below 4.23 wt.%N) among the mixed phases of ${\varepsilon}+{\gamma}$. The ${\varepsilon}$ phase was formed a specific orientation perpendicular to the surface. For $2^{nd}$ transformed layer for S20C steel, ${\gamma}$ phase was rather dominant (just above 2.63 wt.%N). For SPCC steel sheet, there appeared three phases, ${\gamma}$, ${\alpha}(M)$ and weak ${\varepsilon}$ phase. The nitrogen concentration would be approximately 2.6 wt.% in these phases condition.

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.

Field Validation of Earthwork Compaction Quality Control Based on Intelligent Compaction Technology (지능형 다짐 기술 기반 토공사 다짐 품질관리 실증 연구)

  • Baek, Sung-Ha;Kim, Jin-Young;Kim, Jisun;Cho, Jin-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.85-95
    • /
    • 2023
  • This study implemented intelligent compaction technology at the construction site of the AY Highway in Gyeonggi Province, with a focus on obtaining the representative intelligent compaction value, CMV. The target CMV for quality control was established through trial construction, and the validation of the compaction quality control process based on intelligent compaction was conducted. The optimal approach for determining the target CMV was confirmed to be through linear regression of the average CMV measured within a 5-m radius from the plate load testing location. Upon assessing compaction quality against the target CMV, it was observed that the quality criteria outlined in the domestic intelligent compaction standard were met. However, the criteria outlined in Austria and the United States were not satisfied. Notably, indicators related to the variability of compaction quality did not meet the specified criteria, suggesting a stringent standard compared to the observed variability of CMV, ranging from 17% to 55%. Consequently, it is recommended to conduct additional field tests to further validate the compaction quality control process based on intelligent compaction. This will aid in confirming and enhancing the appropriateness of the regulations stipulated in each standard.

A New Correction Method for Ship's Viscous Magnetization Effect on Shipboard Three-component Magnetic Data Using a Total Field Magnetometer (총자력계를 이용한 선상 삼성분 자기 데이터의 선박 점성 자화 효과에 대한 새로운 보정 방법 연구)

  • Hanjin Choe;Nobukazu Seama
    • Geophysics and Geophysical Exploration
    • /
    • v.27 no.2
    • /
    • pp.119-128
    • /
    • 2024
  • Marine magnetic surveys provide a rapid and cost-effective method for pioneer geophysical survey for many purposes. Sea-surface magnetometers offer high accuracy but are limited to measuring the scalar total magnetic field and require dedicated cruise missions. Shipboard three-component magnetometers, on the other hand, can collect vector three components and applicable to any cruise missions. However, correcting for the ship's magnetic field, particularly viscous magnetization, still remains a challenge. This study proposes a new additional correction method for ship's viscous magnetization effect in vector data acquired by shipboard three-component magnetometer. This method utilizes magnetic data collected simultaneously with a sea-surface magnetometer providing total magnetic field measurements. Our method significantly reduces deviations between the two datasets, resulting in corrected vector anomalies with errors as low as 7-25 nT. These tiny errors are possibly caused by the vector magnetic anomaly and its related viscous magnetization. This method is expected to significantly improve the accuracy of shipborne magnetic surveys by providing corrected vector components. This will enhance magnetic interpretations and might be useful for understanding plate tectonics, geological structures, hydrothermal deposits, and more.

Comparison of Nuclear Status and Developmental Potential between Polar Body Extruded Oocytes and Non-extruded Oocytes on in vitro Maturation and Development of Porcine Follicular Oocytes (돼지 난모세포의 체외 성숙 후 극체 방출 및 미방출란의 핵형과 배발달율)

  • Kim, H.J.;Cho, S.R.;Choe, J.Y.;Choi, S.H.;Han, M.H.;Son, D.S.;Kim, Y.G.;Lee, S.S.;Ryu, I.S.;Kim, I.C.;Kim, I.H.;Im, K.S.
    • Journal of Embryo Transfer
    • /
    • v.21 no.3
    • /
    • pp.169-175
    • /
    • 2006
  • The objective of this study was carried out to examine the polar body extrusion of in vitro matured porcine follicular oocytes as a non-invasive marker of oocyte quality to know the developmental competence in advance. The porcine oocytes matured for 48 hours were examined the polar body extrusion and some parts were stained. The examined oocytes were matured for additional $16{\sim}18$ hours and activated with 7% ethanol and cultured in $5{\mu}g/ml$ cytochalasin B for 5 hours for diploid formation. The treated oocytes were washed and cultured for 7 days. The polar body extrusion and degeneration rates were varied with $9.9{\sim}52.4%$ and $21.4{\sim}61.8%$ by repetition. The polar body extruded oocytes were shown the polar body chromosome and metaphase II plate by staining. However the non-extruded oocytes were shown expanded nucleus with 39.1%, premature chromosome condensation with 19.6%, metaphase I plate with 10.9 %, metaphase II with 13%, condensed chromatin with 6.5%, and absent nuclear material with 8.7%. The oocytes that were not examined for the polar body extrusion were cleaved 45.0%, and developed to blastocyst stage with 11.3%. In examined oocytes for polar body extrusion,. the polar body extruded oocytes were cleaved 94.2% and developed with 42.5%. This result suggests that discarding of the degenerating oocytes and oocytes that not extruded polar body will be effective for experiments of culturing effect in porcine embryos and embryo biotechnology.

Changes in the Quality of Beef Jerky Containing Additional Red Wine (적포도주를 첨가한 우육포의 저장 중 품질 변화)

  • Jung, In-Chul;Park, Hyun-Sook;Lee, Kyung-Soo;Choi, Young-Jun;Park, Sung-Sook;Moon, Yoon-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.5
    • /
    • pp.789-796
    • /
    • 2008
  • This study was carried out to investigate the effect of the addition of red wine on the color, water activity, hardness, pH, 2-thiobarbituric acid (TBARS) value, volatile basic nitrogen (VBN) content and total plate count of beef jerky during storage at room temperature for 4 weeks. Beef jerky was prepared using three variations: beef jerky containing 50 mL water (T0), beef jerky containing a combination of 25 mL water and 25 mL red wine (T1) and beef jerky containing 50 mL red wine (T2). The lightness ($L^*$) was the lowest at the 4-week storage period, and the $L^*$ value of T1 and T2 were lower than that of T0 (p<0.05). The redness ($a^*$) tended to decrease during storage, with the $a^*$ value of T1 and T2 being higher than that of the T0 (p<0.05). The yellowness ($b^*$) during storage was not changed, and the $b^*$ value was not significantly different among the different samples tested. The water activity decreased during storage and T0, T1 and T2 was 0.57, 0.57 and 0.60 after 4 weeks of storage, respectively(p<0.05). The hardness increased during storage and the hardness of T2 stored for 4 weeks was lower than that of T0 and T1 (p<0.05). The pH was decreased with an increase in storage time (p<0.05). The TBARS value increased during storage and the TBARS value of T1 and T2 stored for 4 weeks was lower than that of T0 (p<0.05). The VBN content increased during storage and T2 stored for 4 weeks showed the lowest (p<0.05). The total plate count tended to increase during storage, and T0 stored for 4 weeks showed the highest (p<0.05).

  • PDF

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Slipped Capital Femoral Epiphysis(SCFE) (대퇴골두 골단분리증의 치험례)

  • Dan, Jin-Myoung;Kim, Se-Dong
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.245-261
    • /
    • 1997
  • Slipped capital femoral epiphysis(SCFE) is a disorder in which there is a gradual or acute disruption through the capital physeal plate. The physiolysis is through a widened zone of hypertrophy, which is weakened due to altered chondrocytic maturation and endochondral ossification. The cause or causes of SCFE remain uncertain. The association of obesity and adolescent age with growth rate are predisposing factors. The possibility that most patients with subclinical hormonal abnormality were proved. The goal of treatment of slipped capital femoral epiphysis is to restore the function of the hip and delay the development of degenerative osteoarthrosis by prevention of additional displacement of the epiphysis. We report 10 patients(12hips) with SCFE who were treated by surgical means and followed along for more than one year, at Yeungnam University Hospital, from 1989 to 1996. There were six boys and four girls. The average age at operation was 11.8 years. Seven cases occurred in the left hip, one case in the right and 2 cases had bilateral involvement, five cases had a history of minor trauma on affected hip. Among hormonally studied six patients, panhypopituitarism patient was one case; decreased testosterone, two; decreased growth hormone, two; and decreased thyroid hormone, one. According to clinical stage, two cases were the acute type; five cases, acute on chronic type; and three cases, chronic type. On the radiological grades of slipping, mild slippage were nine hips; moderate, one; and severe, two. The eleven hips were treated by pin fixation in situ, and one, by cuneiform osteotomy. On the average follow-up of 2.6 years, ten hips were excellent or good functional results, two hips were failure.

  • PDF