• 제목/요약/키워드: Added filter

검색결과 389건 처리시간 0.028초

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

항산화 필터 제조 및 주류연중 free radicals 제거 효과 (The Manufacture of Antioxidant Filter and Removal Efficiency of the Free Radicals in Mainstream Smoke)

  • 김수호;차성제;심원택;정봉수;서만석;송인범;장행현;신창호;김종열;김정열;최윤주
    • 한국연초학회지
    • /
    • 제31권1호
    • /
    • pp.18-28
    • /
    • 2009
  • This study describes the manufacturing method of antioxidant filter and evaluate the reduction of free radical and biological activity from mainstream smoke. When we used spray-brush for the application of antioxidant solution to the filter, cv(coefficient of variation) levels of antioxidant added to filter ranged within 3 %, which means stable and constant feeding process. 0.3~0.5mg per cigarette of antioxidant were sprayed to acetate and active carbon part in the filter plug, respectively. It was considered that the use of antioxidant added filter resulted in the reduction of the gaseous compounds of free radicals from 17 % to 19 % in the mainstream smoke. Variation for removal efficiency of free radical in antioxidant filter added to acetate part was more pronounced than that of filter added to active carbon part. Smoking deliveries of tar, nicotine for the antioxidant added filters were similar when comparing to the non-antioxidant added filter, but the delivering amounts of isoprene were significantly reduced. The estimation of consumed GSH(glutathion) showed that the gaseous toxicity of the antioxidant added filter was 14 % ~ 23 % lower than that of non-antioxidant added filter. No significant differences were observed for the total taste quality in sensory evaluation.

다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정 (HVL Measurement of the Miniature X-Ray Tube Using Diode Detector)

  • 김주혜;안소현;오윤진;지윤서;허장용;강창무;서현숙;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.279-284
    • /
    • 2012
  • X선은 방사선 진단과 치료 분야에 있어서 다양하고 광범위하게 이용되고 있으며, 최근에는 방사선 치료용 초소형 X선관이 개발되었다. 초소형 X선관은 조사 목적 부위에 직접 삽입하여 사용되므로 제작 시준기에 따라 다양한 각도로 X선 조사가 가능하고, 검사 목적 외의 환자 피폭선량을 최소화한다. 이러한 초소형 X선관의 장점을 이용해서 X선 영상을 획득하는데 적용한다면 X선 진단 분야의 새로운 장을 열 것으로 기대된다. 하지만 초소형 X선관은 본래 치료용으로 설계되었기 때문에 진단용 장비에 적합한 시준기, 필터(added filter) 등이 필요하다. 따라서 자체 제작한 시준기와 필터를 적용하여 초소형 X선관의 빔 특성이 진단용에 적합한지 평가 하였고, 이를 위해서 다이오드 검출기를 이용하여 반가층을 측정하고 측정의 가능성을 평가하였다. 본 연구에서는 Si PIN Photodiode type인 Piranha 검출기(Piranha, RTI, Sweden)를 사용하여 필터 적용 유무에 따른 초소형 X선관의 반가층을 측정하고, 알루미늄 필터를 사용한 측정을 통하여 Piranha 검출기의 반가층 측정의 정확성을 평가하였다. 측정 결과에 따르면 초소형 X선관의 반가층은 필터의 장착에 따라 약 1.9배 증가하여 진단용 방사선 발생 장치의 적합성을 확인하였다. Piranha 검출기의 반가층 자동 측정값은 필터를 미장착한 경우에 실제 반가층 측정값에 비해 50% 높게 측정되어 적용이 불가능하나, 필터를 장착한 경우에는 실제 반가층 측정값과 약 15%의 차이로 감소되었다. 따라서 진단용 필터를 적용했을 경우는 Piranha 검출기의 반가층 자동측정이 가능하여 kV-X선 특성평가를 수월하게 수행할 것으로 기대된다.

Assessment of Bacteria Removal Using Silver Ion Absorbed Ceramic Filter

  • Kim, Woo-Hang;Smith, James
    • 한국환경과학회지
    • /
    • 제21권8호
    • /
    • pp.901-907
    • /
    • 2012
  • The objective of this study was to evaluate bacteria removal ability of the metallic silver which was baked silver ion impregnated ceramic filter at heating condition. Silver leaking from baked ceramic filter was tested to sustain bacteria removal for a long time. Silver impregnated ceramic filter could remove E. coli completely at $10^{12}$ MPN/100ml to $10^{13}$ MPN/100ml of influent. However, ceramic filter without silver did not remove E. coli completely under the same condition. After baking, the silver impregnated ceramic filter almost didn't leak out the silver ion from filter. Photo of TEM (Transmission Electron Microscopy) showed that absorbed silver ions remained in ceramic filter after baking process and most of silver were less than 10 nm. According to the increase in the amount of silver in the ceramic filter, removal efficiencies of E. coli were increased but turbidity removal was decreased. It can be accounted that increased removal efficiency of E. coli was from disinfection of silver that is in the ceramic filter. Simulated concentrations of bacteria agree well with the observed experimental effluent concentration data. Moreover, first-order decay coefficients increased to 0.0034/min after silver was added in the ceramic filter. Increase of first-order decay coefficient proves that silver-added ceramic filter can remove bacteria easily.

임펄스 잡음 제거를 위한 변형된 적응 메디안 필터에 관한 연구 (A Study on Modified Adaptive Median Filter for Impulse Noise Removal)

  • ;안영주;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.804-806
    • /
    • 2014
  • 영상의 처리 및 전송과정에서 여러가지 잡음이 첨가되어 영상에 오류를 발생시킨다. 이러한 영상을 복원하기 위해, 알파 트림드 평균 필터, 표준 메디안 필터, 스위칭 메디안 필터 등의 방법들이 제안되었으나 이러한 기존의 방법들은 잡음제거 특성이 미흡하다. 따라서 본 논문에서는 영상에 첨가되는 임펄스 잡음을 제거하기 위해 마스크 내의 화소의 잡음 밀도에 따라 마스크를 확대 시키는 변형된 적응 메디안 필터 알고리즘을 제안하였다.

  • PDF

흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究) (A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography)

  • 유병헌;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

복합잡음 환경에서 영상 잡음제거를 위한 영상복원 알고리즘 (Image Restoration Algorithm for Image Noise Removal in Mixed Noise Environment)

  • ;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.112-114
    • /
    • 2014
  • 영상은 일반적으로 임펄스 또는 AWGN에 의해 훼손되는 경우가 많으며, 두 가지 잡음이 동시에 첨가될 경우도 있다. 영상에 첨가되는 잡음을 제거함에 있어서 기존의 메디안 필터는 임펄스 잡음제거에 효과적이고 평균필터는 AWGN 제거에 효과적이다. 그러나 기존의 방법은 복합잡음이 첨가될 경우 잡음제거특성이 미흡하며, 이에 따라 본 논문에서는 복합 잡음제거를 위한 비선형 필터 알고리즘을 제안하였다. 시뮬레이션 결과, 제안한 방법은 기존의 방법들에 비해 우수한 잡음제거 특성을 나타내었다.

  • PDF

머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구 (A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection)

  • 이초희;임창선
    • 한국산학기술학회논문지
    • /
    • 제12권7호
    • /
    • pp.3117-3122
    • /
    • 2011
  • 머리부 전후방향촬영은 종래의 증감지-필름 방사선촬영보다 디지털방사선촬영 시 입사표면선량(ESD)이 훨씬 높다. 따라서 본 연구의 목적은 부가필터를 사용하여 환자의 피폭선량을 줄이기 위한 것이다. 본 연구에서는 머리부 팬톰을 이용하여 머리부 전후방향촬영 시 부가여과판의 두께에 따른 선량 감소효과를 알아보았고, 동시에 부가여과판 사용에 따른 영상의 질적 저하의 평가를 위한 실험을 진행하였다. 선량측정은 머리부 팬톰을 머리부 전후방향촬영자 세로 위치시켜 입사표면선량과 투과선량을 0.1 mmAl으로부터 0.5 mmCu+2.0 mmAl까지 16종류의 부가여과판을 바꾸어 가며 측정하였다. 영상의 화질 평가를 위해서 총 17매의 영상을 촬영하였고 촬영된 영상은 영상의학과 전문의에게 평가를 의뢰하였다. 그 결과 부가여과판 중 0.2 mmCu+1.0 mmAl의 복합여과판을 사용한 부가여과판까지 진단적 가치가 있는 영상을 얻었고, 이 때 머리부 팬톰에 입사표면선량은 약 0.6 mGy이었다. 이 값은 국제원자력기구(IAEA)에서 권고하고 있는 머리부 후전방향촬영 시 입사표면선량 5 mGy의 12%에 불과하였다. 따라서 검사부위에 따라 적정한 부가여과판의 사용으로 환자의 피폭선량을 상당히 감소시키는 효과를 얻을 수 있다.

전달선로행렬법을 이용한 흡음재 모델링에 대한 수치해석 (Numerical Analysis for Modeling of Sound Absorbing Medium using Transmission Line Matrix Modeling)

  • 박규칠;윤종락
    • 한국정보통신학회논문지
    • /
    • 제16권8호
    • /
    • pp.1599-1605
    • /
    • 2012
  • 본 연구에서는 해저의 반사면이나 흡음재와 같이 주파수에 따라 다른 특성을 가지는 매체를 시간영역에서 수치적으로 모델링하고자 시간 해석 기법의 하나인 전달선로행렬법을 이용하였다. 기존의 흡음재의 해석에 응용되던 감쇠를 이용하는 방법의 대안으로 유한임펄스응답 필터를 전달선로행렬법에 도입하였다. 7개의 탭을 가진 FIR 필터로 구현하였으며, 시간 지연, 저역통과필터, 고역통과필터의 시뮬레이션 결과를 이론치와 비교하였다. 여러 시뮬레이션 결과를 통해 흡음재의 주파수에 따른 흡음 특성을 유한임펄스응답 필터를 고려한 하나의 요소만으로 모델링하는 것이 가능하다는 것을 확인할 수 있었다.

향상된 SVD 필터를 이용한 Multi-lead ECG에서의 EMG 신호 제거 (EMG Signal Elimination Using Enhanced SVD Filter in Multi-Lead ECG)

  • 박광리;박세진;최호선;정기삼;이경중;윤형로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권6호
    • /
    • pp.302-308
    • /
    • 2001
  • SVD(Singular Value Decomposition) filter for the suppression of EMG in multi-lead stress ECG is studied. SVD filter consists of two parts. In the first part, the basis vectors were chosen from the averaged singular vectors obtained from the decomposed noise-free ECG. The singular vector is computed from the stress ECG and is compared itself with basis vectors to know whether the noise exist in stress ECG. In the second part, the existing elimination method is used, when one(or two) channels is(or are) contaminated by noise. But the proposed enhanced SVD filter is used in case of having the noise in the many channels. During signal decomposition and reconstruction, the noise-free channel or the least noisy channel have the weight of 1, the next less noisy channel has the weight of 0.8. In this way, every channel was weighted by decreased of 0.2 in proportion to the amount of the added noise. For the evaluation of the proposed enhanced SVD filter, we compared the SNR computed by the enhanced SVD filter with the standard average filter for the noise-free signal added with artificial noise and the patient data. The proposed SVD filter showed better in the SNR than the standard average filter. In conclusion, we could find that the enhanced SVD filter is more proper in processing multi-lead stress ECG.

  • PDF