• 제목/요약/키워드: Added Mass Model

검색결과 172건 처리시간 0.017초

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

건강한 중년 남성에서 커피 음용 습관이 혈중 총 콜레스테롤 값에 미치는 영향 (The Effect of Coffee Consumption on Serum Total Cholesterol Level in Healthy Middle-Aged Men)

  • 신명희;김동현;배종면;이형기;이무송;노준양;안윤옥
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권2호
    • /
    • pp.200-216
    • /
    • 1994
  • In present study, the authors investigated the possible effect of coffee consumption on serum cholesterol level in 1017 men between the ages of 40 and 59 years, who were randomly selected from the members of Seoul Cohort Study. Serum total cholesterol data was collected with other serologic indices (e.g. systolic blood pressure, diastolic blood pressure, hight, weight, etc.) through the program of biennial health check-up offered by Korean Medical Insurance Corporation (KMIC). The amount of coffee consumption was assessed by a self-administered questionnaire through mailing. Other confounding factors, such as age, body mass index, cigarette smoking, alcohol consumption, physical activity, and other dietary intake pattern were also determined by the questionnaire. The differences in means of serum total cholesterol in compared to non consumers were $-0.4{\pm}3.56mg/dl$ for those drinking less than 1 cup a day, $-0.6{\pm}3.60mg/dl$ for those drinking 1 cup a day, and $7.1{\pm}3.41mg/dl$ for those drinking more than 2 cups a day. Since smoking interacted the relationship between coffee consumption and serum total choleaterol, we re-analyzed those relationship in smokers and non-smokers separately Other atherogenic behaviors were well correlated with total cholesterol, so we adjusted the mean values of serum total cholesterol through multivariate model selection with age(r=0.12), total cigarette index (cigarette-years; r=0.10), Quetelet's index ($Kg/m^2$, r=0.16), daily calory expenditure (kcal/day, r=0.06), weekly meat and poultry consumption(g/week, r=0.05), weekly fish consumption (g/week, r=0.08), other caffeinated beverage intake (cups/week), and the amount of sugar and prim added to the coffee. Among those variables only age, Quetelet's index, fish consumption, and total cigarette index (in smokers) were remained in the models. After adjustment, the corresponing differences of total cholesterol in smokers were changed to $0.4{\pm}5.24mg/dl,\;-0.5{\pm}4.97mg/dl,\;and\;8.9{\pm}4.78mg/dl$, which were significantly different among themselves (P=0.011). In non-smokers, however, the differences were not statistically significant (P=0.76). Adjusted mean values of systolic blood pressure and diastolic blood pressure were also determined to evaluate the direct effect of coffee to cardiovascular system, but their means were not significantly different by coffee consumption(p=0.18 for SBP, p=0.48 for DBP). Asuming instant coffee in the most popular type of coffee in Korea, the association observed in our study between coffee and serum total cholesterol, especially in smokers, is very interesting finding for the connection between coffee and serum total cholesterol, because only 'boiled coffee' tend to show significant lipid raising effect rather than to other types of coffee, like filtered or espresso, in most of the western countries. We concluded that people who drink coffee more than 2 cups a day have significantly higher serum total cholesterol level than those who never drink coffee, especially in smokers.

  • PDF