• Title/Summary/Keyword: Adaptive Setting

Search Result 118, Processing Time 0.024 seconds

An Automatic Portscan Detection System with Adaptive Threshold Setting

  • Kim, Sang-Kon;Lee, Seung-Ho;Seo, Seung-Woo
    • Journal of Communications and Networks
    • /
    • v.12 no.1
    • /
    • pp.74-85
    • /
    • 2010
  • For the purpose of compromising hosts, attackers including infected hosts initially perform a portscan using IP addresses in order to find vulnerable hosts. Considerable research related to portscan detection has been done and many algorithms have been proposed and implemented in the network intrusion detection system (NIDS). In order to distinguish portscanners from remote hosts, most portscan detection algorithms use a fixed threshold that is manually managed by the network manager. Because the threshold is a constant, even though the network environment or the characteristics of traffic can change, many false positives and false negatives are generated by NIDS. This reduces the efficiency of NIDS and imposes a high processing burden on a network management system (NMS). In this paper, in order to address this problem, we propose an automatic portscan detection system using an fast increase slow decrease (FISD) scheme, that will automatically and adaptively set the threshold based on statistical data for traffic during prior time periods. In particular, we focus on reducing false positives rather than false negatives, while the threshold is adaptively set within a range between minimum and maximum values. We also propose a new portscan detection algorithm, rate of increase in the number of failed connection request (RINF), which is much more suitable for our system and shows better performance than other existing algorithms. In terms of the implementation, we compare our scheme with other two simple threshold estimation methods for an adaptive threshold setting scheme. Also, we compare our detection algorithm with other three existing approaches for portscan detection using a real traffic trace. In summary, we show that FISD results in less false positives than other schemes and RINF can fast and accurately detect portscanners. We also show that the proposed system, including our scheme and algorithm, provides good performance in terms of the rate of false positives.

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

Developed Ability of Zero-phase Overcurrent Relay by Changed setting point value (설정치 변경에 의한 영상과전류계전기의 성능개선)

  • Kim, N.H.;Yoon, D.S.;Chang, S.I.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.220-222
    • /
    • 1998
  • This paper presents a method, which develops an ability of Zero-phase Overcurrent Relay. Zero-phase current is very useful factor of Fault decision in Protect Relaying system. Actually, the setting-point value of Designed Relay, using Zero-phase current, is fixed. So in the case of deciding fault, Fixed setting-point value is not suitable for changing Load. and cause errors in Distributions system. For solving this problem, This paper proposes the Changed setting point value Algorithm, which can be adaptive for changing Distributions system using Zero-phase current r.m.s. indexes. The results of simulation under Load changing and High impedance fault show that proposed algorithm is useful for changing Distributions system and decreasing errors.

  • PDF

Optimum Setting of Overcurrent Relay in Distribution Systems Using Adaptive Evolutionary Algorithm (적응진화 알고리즘을 이용한 배전계통의 과전류보호계전기 최적 정정치 결정)

  • Jeong, Hee-Myung;Park, June-Ho;Lee, Hwa-Seok;Mun, Kyeong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.252-253
    • /
    • 2006
  • This paper presents OC relay coordination to protect distribution system by Adaptive Evolutionary Algorithm(AEA). AEA is a optimization method to overcome the problems of classical optimization. The results show that the proposed method can improve more optimum relay settings than present available methods.

  • PDF

Fuzzy logic control of a planar parallel manipulator using multi learning algorithm (다중 학습 알고리듬을 이용한 평면형 병렬 매니퓰레이터의 Fuzzy 논리 제어)

  • Song, Nak-Yun;Cho, Whang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.8
    • /
    • pp.914-922
    • /
    • 1999
  • A study on the improvement of tracking performance of a 3 DOF planar parallel manipulator is performed. A class of adaptive tracking control sheme is designed using self tuning adaptive fuzzy logic control theory. This control sheme is composed of three classical PD controller and a multi learning type self tuning adaptive fuzzy logic controller set. PD controller is tuned roughly by manual setting a priori and fuzzy logic controller is tuned precisely by the gradient descent method for a global solution during run-time, so the proposed control scheme is tuned more rapidly and precisely than the single learning type self tuning adaptive fuzzy logic control sheme for a local solution. The control performance of the proposed algorithm is verified through experiments.

  • PDF

An Adaptive Setting Method for the Overcurrent Relay of Distribution Feeders Considering the Interconnected Distributed Generations

  • Jang Sung-Il;Kim Kwang-Ho;Park Yong-Up;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Lee Seung-Jae;Oshida Hideharu;Park Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.357-365
    • /
    • 2005
  • This research investigates the influences of distributed generations (DG), which are interconnected to the bus by the dedicated lines, on the overcurrent relays (OCR) of the neighboring distribution feeders and also proposes a novel method to reduce the negative effects on the feeder protection. Due to the grid connected DG, the entire short-circuit capacity of the distribution networks increases, which may raise the current of the distribution feeder during normal operations as well as fault conditions. In particular, during the switching period for loop operation, the current level of the distribution feeder can be larger than the pickup value for the fault of the feeder's OCR, thereby causing the OCR to perform a mal-operation. This paper proposes the adaptive setting algorithm for the OCR of the distribution feeders having the neighboring dedicated feeders for the DG to prevent the mal-operations of the OCR under normal conditions. The proposed method changes the pickup value of the OCR by adapting the power output of the DG monitored at the relaying point in the distribution network. We tested the proposed method with the actual distribution network model of the Hoenggye substation at the Korea Electric Power Co., which is composed of five feeders supplying the power to network loads and two dedicated feeders for the wind turbine generators. The simulation results demonstrate that the proposed adaptive protection method could enhance the conventional OCR of the distribution feeders with the neighboring dedicated lines for the DG.

Damage Detection of Building Structures using AEKF(Adaptive Extended Kalman Filter) (AEKF(Adaptive Extended Kalman Filter)를 이용하는 건축 구조물의 손상탐지)

  • Yun, Da Yo;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.45-54
    • /
    • 2019
  • The damage detection method using the extended Kalman filter(EKF) technique has been continuously used since EKF can estimation the responses of the damaged building structure and the stiffness of the structure. However, in the use of EKF, the requirement of setting the initial paramters P, Q, and R has caused the divergence and instability of the state vector, and various researches have been conducted to determine theses parameters. In this paper, adaptive extended Kalman filter(AEKF) method is proposed to solve the problem of setting the values of P, Q, and R, which are important parameters determining the convergence performance of the EKF state vector. By using the AEKF method proposed in this study, the P, Q, and R parameters are updated every k steps. The proposed algorithm is applied for the estimation of stiffness and the damage detection of 3-DOF problem. Based of the verification, it can be found that the selection process for the values of P, Q, and R can improve the convergence performance of EKF.

Optimal Adaptive Multiband Spectrum Sensing in Cognitive Radio Networks

  • Yu, Long;Wu, Qihui;Wang, Jinlong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.3
    • /
    • pp.984-996
    • /
    • 2014
  • In this paper, optimal sensing time allocation for adaptive multiband spectrum sensing-transmission procedure is investigated. The sensing procedure consists of an exploration phase and a detection phase. We first formulate an optimization problem to maximize the throughput by designing not only the overall sensing time, but also the sensing time for every stage in the exploration and detection phases, while keeping the miss detection probability for each channel under a pre-defined threshold. Then, we transform the initial non-convex optimization problem into a convex bilevel optimization problem to make it mathematically tractable. Simulation results show that the optimized sensing time setting in this paper can provide a significant performance gain over the previous studies.

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

An Adaptive USB(Universal Serial Bus) Protocol for Improving the Performance to Transmit/Receive Data (USB(Universal Serial Bus)의 데이터 송수신 성능향상을 위한 적응성 통신방식)

  • Kim, Yoon-Gu;Lee, Ki-Dong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.327-332
    • /
    • 2004
  • USB(Universal Serial Bus) is one of the most popular communication interfaces. When USB is used in an extended range, especially configurating In-home network by connecting multiple digital devices each other, USB interface uses the bandwidth in the way of TDM(Time Division Multiplexing) so that the bottleneck of bus bandwidth can be brought. In this paper, the more effective usage of bus bandwidth to overcome this situation is introduced. Basically, in order to realize the system for transferring realtime moving picture data among digital information devices, we analyze USB transfer types and Descriptors and introduce the method to upgrade detailed performance of Isochronous transfer that is one of USB transfer types. In the case that Configuration descriptor of a device has Interface descriptor that has two AlternateSetting, if Isochronous transfers are not processed smoothly due to excessive bus traffic, the application of the device changes AlternateSetting of the Interface descriptor and requires a new configuration by SetInterface() request. As a result of this adaptive configuration, the least data frame rate is guaranteed to a device that the sufficient bandwidth is not alloted. And if the bus traffic is normal, the algorithm to return to the original AlteranteSetting is introduced. this introduced method resolve the bottleneck of moving picture transfer that can occur in home network connected by multiple digital devices.

  • PDF