• Title/Summary/Keyword: Adaptive Contrast

Search Result 245, Processing Time 0.032 seconds

A New Connected Operator Using Morphological Reconstruction for Region-Based Coding (영역 기반 부호화를 위한 새로운 수리형태학 기반의 Connected Operator)

  • Kim, Tae-Hyeon;Moon, Young-Shik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.37-48
    • /
    • 2000
  • In this paper, we propose a new connected operator Using morphological grayscale reconstruction for region-based coding First, an effective method of reference-image creation lis proposed, which is based on the Size as well as the contrast. This improves the performance of simplification, because It preserves perceptually important components and removes unnecessary components The conventional connected operators are good for removing small regions, but have a serious drawback for low-contrast regions that are larger than the structuring element. That is, when the conventional connected operators are applied to tills region, the simplification becomes less effective or several meaningful regions are merged to one region to avoid this, the conventional geodesic dilation is modified to propose an adaptive operator to reduce the effect of inappropriate propagation, pixels reconstructed to the original values are excluded m the dilation operation Experimental results have shown that the proposed algorithm achieves better performance In terms of the reconstruction of flat zones. The Picture quality has also been improved by about 7dB, compared to the conventional methods.

  • PDF

Evaluation of U-Net Based Learning Models according to Equalization Algorithm in Thyroid Ultrasound Imaging (갑상선 초음파 영상의 평활화 알고리즘에 따른 U-Net 기반 학습 모델 평가)

  • Moo-Jin Jeong;Joo-Young Oh;Hoon-Hee Park;Joo-Young Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.29-37
    • /
    • 2024
  • This study aims to evaluate the performance of the U-Net based learning model that may vary depending on the histogram equalization algorithm. The subject of the experiment were 17 radiology students of this college, and 1,727 data sets in which the region of interest was set in the thyroid after acquiring ultrasound image data were used. The training set consisted of 1,383 images, the validation set consisted of 172 and the test data set consisted of 172. The equalization algorithm was divided into Histogram Equalization(HE) and Contrast Limited Adaptive Histogram Equalization(CLAHE), and according to the clip limit, it was divided into CLAHE8-1, CLAHE8-2. CLAHE8-3. Deep Learning was learned through size control, histogram equalization, Z-score normalization, and data augmentation. As a result of the experiment, the Attention U-Net showed the highest performance from CLAHE8-2 to 0.8355, and the U-Net and BSU-Net showed the highest performance from CLAHE8-3 to 0.8303 and 0.8277. In the case of mIoU, the Attention U-Net was 0.7175 in CLAHE8-2, the U-Net was 0.7098 and the BSU-Net was 0.7060 in CLAHE8-3. This study attempted to confirm the effects of U-Net, Attention U-Net, and BSU-Net models when histogram equalization is performed on ultrasound images. The increase in Clip Limit can be expected to increase the ROI match with the prediction mask by clarifying the boundaries, which affects the improvement of the contrast of the thyroid area in deep learning model learning, and consequently affects the performance improvement.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

Effect of Small Dose of Radiation on Induction of Apoptosis in Murine Tumors (마우스 종양에서 저선량 방사선이 Apoptosis의 유도에 미치는 영향)

  • Seong, Jin-Sil;Pyo, Hong-Ryull;Chung, Eun-Ji;Kim, Sung-Hee;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.307-313
    • /
    • 1999
  • Purpose : To investigate the Presence of adaptive response by low dose radiation in murine tumors in relation to radiation induced apoptosis as well as related mechanism. Materials and Methods : Syngeneic murine tumors, OCa-I and HCa-l, were given 0.05 Gy pretreatment followed by therapeutic dose of 25 Gy radiation. Induction of apoptosis was analyzed for each treatment group. Regulating molecules of apoptosis, p53, Bcl-2, Bax, Bcl-X, were also analyzed by Western blotting. Results : In 0.05 Gy pretreatment group of OCa-I, 25 Gy-induced apoptosis per 1000 cells was 229, which was estimated at $30\%$ lower level than the expected (p<0.05). In contrast, this reduction in radiation induced apoptosis was not seen in HCa-l. In the expression of apoptosis regulating molecules, p53 increased in both tumors in response to radiation. Bcl-2 and Bax did not show significant change in both tumors however, the expression of Bcl-2 surpassed that of Bax in 0.05 Gy pretreatment group of OCa-l. Bcl-X was not expressed in OCa-l. In HCa-l, Bcl-X showed increased expression even with 0.05 Gy. Conclusion : Adaptive response by low dose radiation Is shown in one murine tumor, OCa-l, in relation to radiation induced apoptosis. Apoptosis regulating molecules including Bcl-2/Bax and Bcl-X, appear to related. This study shows an evidence that adaptive response is present, but not a generalized phenomenon in vivo.

  • PDF

The Effect of Mean Brightness and Contrast of Digital Image on Detection of Watermark Noise (워터 마크 잡음 탐지에 미치는 디지털 영상의 밝기와 대비의 효과)

  • Kham Keetaek;Moon Ho-Seok;Yoo Hun-Woo;Chung Chan-Sup
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.305-322
    • /
    • 2005
  • Watermarking is a widely employed method tn protecting copyright of a digital image, the owner's unique image is embedded into the original image. Strengthened level of watermark insertion would help enhance its resilience in the process of extraction even from various distortions of transformation on the image size or resolution. However, its level, at the same time, should be moderated enough not to reach human visibility. Finding a balance between these two is crucial in watermarking. For the algorithm for watermarking, the predefined strength of a watermark, computed from the physical difference between the original and embedded images, is applied to all images uniformal. The mean brightness or contrast of the surrounding images, other than the absolute brightness of an object, could affect human sensitivity for object detection. In the present study, we examined whether the detectability for watermark noise might be attired by image statistics: mean brightness and contrast of the image. As the first step to examine their effect, we made rune fundamental images with varied brightness and control of the original image. For each fundamental image, detectability for watermark noise was measured. The results showed that the strength ot watermark node for detection increased as tile brightness and contrast of the fundamental image were increased. We have fitted the data to a regression line which can be used to estimate the strength of watermark of a given image with a certain brightness and contrast. Although we need to take other required factors into consideration in directly applying this formula to actual watermarking algorithm, an adaptive watermarking algorithm could be built on this formula with image statistics, such as brightness and contrast.

  • PDF

Spectral Analysis Method to Eliminate Spurious in FMICW HRR Millimeter-Wave Seeker (주파수 변조 단속 지속파를 이용하는 고해상도 밀리미터파 탐색기의 스퓨리어스 제거를 위한 스펙트럼 분석 기법)

  • Yang, Hee-Seong;Chun, Joo-Hwan;Song, Sung-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.85-95
    • /
    • 2012
  • In this thesis, we develop a spectral analysis scheme to eliminate the spurious peaks generated in HRR Millimeterwave Seeker based on FMICW system. In contrast to FMCW system, FMICW system generates spurious peaks in the spectrum of its IF signal, caused by the periodic discontinuity of the signal. These peaks make the accuracy of the system depend on the previously estimated range if a band pass filter is utilized to eliminate them and noise floor go to high level if random interrupted sequence is utilized and in case of using staggering process, we must transmit several waveforms to obtain overlapped information. Using the spectral analysis one of the schemes such as IAA(Iterative Adaptive Approach) and SPICE(SemiParametric Iterative Covariance-based Estimation method) which were introduced recently, the spurious peaks can be eliminated effectively. In order to utilize IAA and SPICE, since we must distinguish between reliable data and unreliable data and only use reliable data, STFT(Short Time Fourier Transform) is applied to the distinguishment process.

A Study on Projection Image Restoration by Adaptive Filtering (적응적 필터링에 의한 투사영상 복원에 관한 연구)

  • 김정희;김광익
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.119-128
    • /
    • 1998
  • This paper describes a filtering algorithm which employs apriori information of SPECT lesion detectability potential for the filtering of degraded projection images prior to the backprojection reconstruction. In this algorithm, we determined m minimum detectable lesion sized(MDLSs) by assuming m object contrasts uniformly-chosen in the range of 0.0-1.0, based on a signal/noise model which provides the capability potential of SPECT in terms of physical factors. A best estimate of given projection image is attempted as a weighted combination of the subimages from m optimal filters whose design is focused on maximizing the local S/N ratios for the MDLS-lesions. These subimages show relatively larger resolution recovery effect and relatively smaller noise reduction effect with the decreased MDLS, and the weighting on each subimage was controlled by the difference between the subimage and the maximum-resolution-recovered projection image. The proposed filtering algoritym was tested on SPECT image reconstruction problems, and produced good results. Especially, this algorithm showed the adaptive effect that approximately averages the filter outputs in homogeneous areas and sensitively depends on each filter strength on contrast preserving/enhancing in textured lesion areas of the reconstructed image.

  • PDF

Automatic Liver Segmentation of a Contrast Enhanced CT Image Using a Partial Histogram Threshold Algorithm (부분 히스토그램 문턱치 알고리즘을 사용한 조영증강 CT영상의 자동 간 분할)

  • Kyung-Sik Seo;Seung-Jin Park;Jong An Park
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.189-194
    • /
    • 2004
  • Pixel values of contrast enhanced computed tomography (CE-CT) images are randomly changed. Also, the middle liver part has a problem to segregate the liver structure because of similar gray-level values of a pancreas in the abdomen. In this paper, an automatic liver segmentation method using a partial histogram threshold (PHT) algorithm is proposed for overcoming randomness of CE-CT images and removing the pancreas. After histogram transformation, adaptive multi-modal threshold is used to find the range of gray-level values of the liver structure. Also, the PHT algorithm is performed for removing the pancreas. Then, morphological filtering is processed for removing of unnecessary objects and smoothing of the boundary. Four CE-CT slices of eight patients were selected to evaluate the proposed method. As the average of normalized average area of the automatic segmented method II (ASM II) using the PHT and manual segmented method (MSM) are 0.1671 and 0.1711, these two method shows very small differences. Also, the average area error rate between the ASM II and MSM is 6.8339 %. From the results of experiments, the proposed method has similar performance as the MSM by medical Doctor.

Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise

  • Joo Hee Kim;Hyun Jung Yoon;Eunju Lee;Injoong Kim;Yoon Ki Cha;So Hyeon Bak
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.131-138
    • /
    • 2021
  • Objective: Iterative reconstruction degrades image quality. Thus, further advances in image reconstruction are necessary to overcome some limitations of this technique in low-dose computed tomography (LDCT) scan of the chest. Deep-learning image reconstruction (DLIR) is a new method used to reduce dose while maintaining image quality. The purposes of this study was to evaluate image quality and noise of LDCT scan images reconstructed with DLIR and compare with those of images reconstructed with the adaptive statistical iterative reconstruction-Veo at a level of 30% (ASiR-V 30%). Materials and Methods: This retrospective study included 58 patients who underwent LDCT scan for lung cancer screening. Datasets were reconstructed with ASiR-V 30% and DLIR at medium and high levels (DLIR-M and DLIR-H, respectively). The objective image signal and noise, which represented mean attenuation value and standard deviation in Hounsfield units for the lungs, mediastinum, liver, and background air, and subjective image contrast, image noise, and conspicuity of structures were evaluated. The differences between CT scan images subjected to ASiR-V 30%, DLIR-M, and DLIR-H were evaluated. Results: Based on the objective analysis, the image signals did not significantly differ among ASiR-V 30%, DLIR-M, and DLIR-H (p = 0.949, 0.737, 0.366, and 0.358 in the lungs, mediastinum, liver, and background air, respectively). However, the noise was significantly lower in DLIR-M and DLIR-H than in ASiR-V 30% (all p < 0.001). DLIR had higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than ASiR-V 30% (p = 0.027, < 0.001, and < 0.001 in the SNR of the lungs, mediastinum, and liver, respectively; all p < 0.001 in the CNR). According to the subjective analysis, DLIR had higher image contrast and lower image noise than ASiR-V 30% (all p < 0.001). DLIR was superior to ASiR-V 30% in identifying the pulmonary arteries and veins, trachea and bronchi, lymph nodes, and pleura and pericardium (all p < 0.001). Conclusion: DLIR significantly reduced the image noise in chest LDCT scan images compared with ASiR-V 30% while maintaining superior image quality.

Sampling Strategies for Computer Experiments: Design and Analysis

  • Lin, Dennis K.J.;Simpson, Timothy W.;Chen, Wei
    • International Journal of Reliability and Applications
    • /
    • v.2 no.3
    • /
    • pp.209-240
    • /
    • 2001
  • Computer-based simulation and analysis is used extensively in engineering for a variety of tasks. Despite the steady and continuing growth of computing power and speed, the computational cost of complex high-fidelity engineering analyses and simulations limit their use in important areas like design optimization and reliability analysis. Statistical approximation techniques such as design of experiments and response surface methodology are becoming widely used in engineering to minimize the computational expense of running such computer analyses and circumvent many of these limitations. In this paper, we compare and contrast five experimental design types and four approximation model types in terms of their capability to generate accurate approximations for two engineering applications with typical engineering behaviors and a wide range of nonlinearity. The first example involves the analysis of a two-member frame that has three input variables and three responses of interest. The second example simulates the roll-over potential of a semi-tractor-trailer for different combinations of input variables and braking and steering levels. Detailed error analysis reveals that uniform designs provide good sampling for generating accurate approximations using different sample sizes while kriging models provide accurate approximations that are robust for use with a variety of experimental designs and sample sizes.

  • PDF