• Title/Summary/Keyword: Acute angle

Search Result 161, Processing Time 0.022 seconds

Holographic recording system by combined use of rotational, angular, and spatial multiplexing method (회전, 각, 그리고 공간 다중화 방법을 결합사용한 홀로그램 기록 시스템)

  • 신동학;장주석
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.199-204
    • /
    • 1998
  • To increase the storage density in hologram recording, a simple scheme to obtain rotational, angular and spatial multiplexing efficiently at the same time is proposed and experimented. Both rotational multiplexing and angular multiplexing are obtained by controlling the reference beam directly by use of a pair of wedge prisms, while spatial multiplexing is obtained by shifting the recording medium in the recording plane. It is possible to get both an acute-angle geometry, in which the angle between the signal and reference beams is less than 90$^{\circ}$, and a 90$^{\circ}$ geometry, in which the angle is approximately 90$^{\circ}$. In experiment, 180 holograms were multiplexed with an acute-angle geometry where a photopolymer was used for the recording medium, and 147 holograms with 90$^{\circ}$ geometry where a Fe-doped LiNbO$_3$ crystal was used. The proposed scheme makes it easy it easy to realize a practical holographic memory system by simplifying the control of three complex mechanical motions that are necessary for the three multiplexing techniques.

  • PDF

Lower facial contouring surgery using a novel method: M-genioplasty

  • Lee, June Bok;Han, Jin Woo;Park, Jun Hyung;Min, Kyung Hee
    • Archives of Plastic Surgery
    • /
    • v.45 no.6
    • /
    • pp.572-577
    • /
    • 2018
  • Background Mandibular contouring surgery to produce a more slender and small face has become popular, especially in East Asia. Narrowing genioplasty should be simultaneously performed with mandibular angle resection to achieve satisfactory results. In Korea, T-genioplasty has been frequently performed for chin narrowing. The authors developed a new, safe, and reliable method, termed M-genioplasty, that can provide a more slender and attractive lower face. Methods From June 2013 to December 2017, 36 patients underwent M-genioplasty with mandibular angle resection for lower facial contouring. Horizontal and vertical osteotomies were performed obliquely. The resected bone segments were wedge-shaped. The remaining two bone segments were rotated and approximated centrally. The lateral mandible bony step-off was trimmed off for mandibular angle resection. Results In all patients, the facial contour sufficiently improved, and most patients were satisfied with the outcome. No severe complications took place during postoperative follow-up. Conclusions M-genioplasty can provide more mandibular angle resection and can create a more acute chin angle without bone resorption than other methods, including T-genioplasty. M-genioplasty with mandibular angle resection is a safer, more accurate, and more reliable method for lower facial contouring.

THE CLINICAL STUDY OF MANDIBULAR FRACTURE

  • Lee, Dong-Keun;Yim, Chang-Joon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1989
  • This is a retrospective study on 219 patients with mandibular fracture. The patients were treated in the Dept. of Oral Maxillofacial Surgery of WON KWANG UNIV. HOSPITAL from Aug. 1, 1984 to Sept. 30. 1988. The results were as follows. 1. The mandibular fractures occured most frequently in the twenties(35%) and male were predominant (74.7%) than females. 2. The most frequent etiologic factor was traffic accident(34.3%). 3. The most common location of fracture was symphysis(37.1%). And angle(27.6%), condyle(25.7%), ramus(1.6%) were next in order of frequency. 4. In mandible fracture, they have an average 1.8 fracture line. 5. The use of plate & screw system were more increased in the comparison of each year. 6. Intermaxillary fixation period was more reduced from the concept of 6 weeks fixation, due to the use of Plate & screw system. 7. Postoperative acute wound infection was developed 9.6% in 219 mandibular fracture patients. The compression osteosynthesis was most common cause of acute wound infection than any other treatment method. 8. Postoperative malocclusion was developed 4% in 219 mandibular fracture. And the compression osteosynthesis was most common cause of malocclusion. 9. Acute wound infection was detailed by the approach method. The Intraoral & extraoral combination method was most common cause on acute infection and intraoral, extraoral approach method was next in order of frequency. 10. Normal mouth opening process was proportioned to IMF period. The short IMF period have a fast normal mouth opening process.

  • PDF

Characteristics of Vortical Jet Structures of a Hydrofoil

  • Yang, Chang-Jo;Kim, You-Taek;Choi, Min-Seon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.7
    • /
    • pp.842-851
    • /
    • 2007
  • Oscillating foil propulsion, the engineering application of fish-like movement of a hydrofoil, has received in recent decades as a possible competitor for propellers. The oscillating foil produces an effective angle of attack, resulting in a normal force vector with thrust and lift components, and it can be expected to be a new highly effective propulsion system. We have explored propulsion hydrodynamics as a concept in wake flow pattern. The present study has been examined various conditions such as oscillating frequencies and amplitudes in NACA0010 profile. Flow visualizations showed that high thrust was associated with the generation of moderately strong vortices, which subsequently combine with trailing-edge vorticity leading to the formation of a reverse $K\acute{a}rm\acute{a}n$ vortex street. Vortex generation was inherent to jet production and playeda fundamental role in the wake dynamics. And it was shown that the strong thrust coefficient obtained as the Strouhal number was larger.

A study of the spatial amplification of the Type II instability for the Rotating-disk flow (회전원판 유동의 제2형 불안정성 공간증폭에 관한 이론적 연구)

  • Lee, Yun-Yong;Lee, Kwang-Won;Hwang, Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.481-486
    • /
    • 2001
  • The hydrodynamic instability of the three-dimensional boundary layer on a rotating disk introduces a periodic modulation of the mean flow in the form of stationary cross flow vortices. Detailed numerical values of the growth rates, neutral curves and other characteristics have been calculated for the Type II-instabilities. Presented are the neutral stability results concerning the two instability modes by solving new linear stability equations reformulated not only by considering whole convective terms but by correcting some errors in the previous stability equations. The present stability results are agree with the previously known ones within reasonable limit. The spatial amplification contours have been calculated for the moving disturbance wave, whose azimuth angle is between $\varepsilon=-10^{\circ}$ and $-20^{\circ}$. The transition flow of the moving disturbance wave will be developed at $\varepsilon=-15^{\circ}$ and Re=352 corresponding at the growth rates n = 5.8 from the spatial amplification contours.

  • PDF

Biomechanical Analysis of Injury Factors in the Run UP and Jump Phases of the Jetѐ (발레 Jetė 동작의 도움닫기와 점프구간에서 상해 발생 요인에 대한 생체역학적 분석)

  • Lee, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.295-304
    • /
    • 2012
  • This study, through biomechanical analysis, conducts a risk assessment of injury occurrence in ballet dancers while they perform running and jumping movements. The participants were nine female collegiate students majoring in ballet(age: $20.89{\pm}1.17years$; height: $160.89{\pm}7.01cm$; mass: $48.89{\pm}3.26$). Descriptive data were expressed as $mean{\pm}standard$ deviation(SD) for all variables. An independent t-test was conducted to determine how the following variables differed: duration time, position of the center of gravity, angle of the hip, torque of the hip, and muscle activity. All comparisons were made at the p<0.05 significance level. The results show that the jump time was two times longer than the run time in the duration time. The jump length was also longer than the run. The angle of the hip and the torque at the hip were higher in the right. The vastus medialis muscle was most frequently used. These findings demonstrate that participants' jumps may require more biomechanical variables for performance of better and more correct $jet{\acute{e}}$.

Primary angle-closure glaucoma, a rare but severe complication after blepharoplasty: Case report and review of the literature

  • Maria Kappen, Isabelle Francisca Petronella;Nguyen, Duy Thuan;Vos, Albert;van Tits, Hermanus Wilhelmus Hendricus Joseph
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.384-387
    • /
    • 2018
  • Blepharoplasty is one of the most commonly performed aesthetic procedures. Surgical complications are rare, but can have severe consequences, such as permanent vision loss. In this report, we describe a patient who developed primary angle-closure glaucoma (ACG) with associated vision loss after a oculoplastic procedure using local anesthesia. So far, six similar cases have been described in the literature. It is believed that acute ACG is triggered by the surgical procedure in patients with predisposing risk factors such as a cataract. Surgical triggering factors include the use of buffered lidocaine/xylocaine with adrenaline/epinephrine, stress, and coverage of the eyes postoperatively. Due to postoperative analgesic use, the clinical presentation can be mild and atypical, leading to a significant diagnostic delay. Acute ACG should therefore be excluded in each patient with postoperative complaints by assessing pupillary reactions. If a fixed mid-wide pupil is observed in an ophthalmologic examination, an immediate ophthalmology referral is warranted. Surgeons should be aware of this rare complication in order to offer treatment at an early stage and to minimize the chance of irreversible vision loss.

The Effect of Muscle Reeducation Training on Recovery and Function in People with Acute Facial Nerve Paralysis (근재교육훈련이 급성안면신경마비 환자의 안면마비 회복정도와 기능에 미치는 효과)

  • Park, Sang-Kyu;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.4
    • /
    • pp.240-248
    • /
    • 2014
  • Purpose: The purpose of study was to determine the effects of muscle reeducation training in patients with acute facial nerve paralysis. Methods: Thirty patients were randomly assigned to either the experimental group (n=15) or the control group (n=15). The experimental group received muscle reeducation training for 20 minutes after electrotherapy and the control group received conventional electrotherapy for only 40 minutes. Therapeutic intervention for each group was performed four times per week for four weeks. The patients were measured for recovery of paralysis using the House-Brackmann Grading System (H-B grade), the Movement Distance of Mouth, Nasolabial Angle (NA), and Facial Disability Index (FDI). Results: In within group comparison, the experimental group showed significant improvements for all variables (p<0.01). In comparison between two groups, the experimental group showed relatively greater significant improvements for all variables (p<0.01). Conclusion: These findings suggest that muscle reeducation training is more effective than conventional therapy in improving the condition of patients with facial nerve paralysis. In particular, the results of this study indicate that muscle reeducation training can be recommended by clinicians since it provides more benefits.

Study on Influence of Process Parameter on Stretch Flangeability of Steel Sheet (판재 신장플랜지성에 미치는 전단 공정 인자의 영향 연구)

  • S.S. Han;H.Y. Lee
    • Transactions of Materials Processing
    • /
    • v.32 no.2
    • /
    • pp.61-66
    • /
    • 2023
  • The quality of the sheared surface affects the stretch flangeability of steel sheet. The quality of sheared surface is influenced by several process factors such as die clearance, shape of cutting edge, use of counter punch, and shear. In this paper, the influence of these shearing process factors on the stretch flangeability of the HSS (DP980) was analyzed through a shearing and a stretch flangeability test. When the die clearance was 10%, the effect of these shearing process factors on the stretch flangeability was the greatest, and the use of an acute angle blade was found to be more advantageous in the stretch flangeability than a right angle blade. It was found that the stretch flangeability was improved when active bending was applied during shearing.

Study on a moir$\acute{e}$ Artifact in the Use of Carbon Interspaced Antiscatter Grids for Digital Radiography (탄소 중간물질 그리드를 사용한 DR system에서의 moir$\acute{e}$ artifact에 관한 연구)

  • Lee, Sung-Ju;Cho, Hyo-Sung;Choi, Sung-Il;Cho, Hee-Moon;Oh, Ji-Eun;Lee, So-Young;Park, Yeon-Ok;Lee, Min-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.5-9
    • /
    • 2008
  • Antiscatter grids are widely used in radiography to remove scattered X-rays and thus improve the image contrast. However, the use of grids makes moir$\acute{e}$ artifact in the digital image, and this can be a critical reason for a mistaken diagnosis. In this paper, we examined that moire artifacts are how to relate with grid frequency, pixel pitch and grid rotation angle. To experiment we prepared 6 grids having different line frequencies (4.0 to 8.5lines/mm) and tested with a DR imager having a $139{\mu}m{\times}139{\mu}m$ pixel size. In the result of this experiment, we could get data about moir$\acute{e}$ artifact that could be make solution to remove the line artifact for the successful use of the grid in digital radiography. The acquired data and theory through this experiment, are expected to make contribution to the elimination of moir$\acute{e}$ artifact in the DR system.

  • PDF