• Title/Summary/Keyword: Actual power

Search Result 2,272, Processing Time 0.025 seconds

Development of Onboard Power Supply Device for Precision Guided Kit (정밀유도 비행체 탑재용 전원공급장치 개발)

  • Park, Deok-Bae;Kim, Hyung-Shin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.209-214
    • /
    • 2008
  • A precision guided kit is a GPS/INS guided range extension system to improve the accuracy and availability of existing dumb bombs. The PSD(power supply device) installed in the GPS guided kit supplies electrical power to all electrical loads in the kit. In this paper, design process and test results of the PSD have been presented. Additionally, the performance results of the PSD during actual ground and flight tests have been described.

Analysis of Performance of Data Communications Using Error Control Codes on Electrical Power Lines (전력선에서의 에러 정정 코드에 의한 데이터 전송 성능 분석)

  • 송왕철;정호영;김신령;강창언
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.5
    • /
    • pp.339-346
    • /
    • 1991
  • In this paper the performance of communication system in the electrical power line using error correcting codes is analysed. The BCH codes and interleaved code are to be used for correcting burst and random errors in the power line channels. The data rate of 2400 bps and the carrier frequency of 12KHz are assumed. Actual power line noise is recorded and simulated in the BPSK PLC system model.

  • PDF

Design of a Discrete Flux Observer by the Power Series Approximation

  • Kim, Kyung-Seo;Kim, Il-Han
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.304-310
    • /
    • 2011
  • The power series approximation method is proposed for real time implementations of a discrete flux observer. The proposed method improves the performance of the discrete flux observer in the case of a low sampling rate and high speed range, where the simple discrete flux observer converted by the Euler method cannot estimate the actual flux precisely. The performance of discrete flux observers with different orders of approximation is compared to find out the proper order of approximation. The validity of the proposed method is verified through simulation and experiment.

Analysis of Variables Effects in 300mm PECVD Chamber Cleaning Process Using NF3

  • Sang-Min Lee;Hee-Chan Lee;Soon-Oh Kwon;Hyo-Jong Song
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2024
  • NF3, Chamber cleaning gas, has a high Global Warming Potential (GWP) of 17,000, causing significant greenhouse effects. Reducing gas usage during the cleaning process is crucial while increasing the cleaning Rate and reducing cleaning standard deviation (Stdev). In a previous study with a 6-inch PECVD chamber, a multiple linear regression analysis showed that Power and Pressure had no significant effect on the cleaning Rate because of their P-values of 0.42 and 0.68. The weight for Flow is 11.55, and the weights for Power and Pressure are 1.4 and 0.7. Due to the limitations of the research equipment, which differed from those used in actual industrial settings, it was challenging to assess the effects in actual industrial environment. Therefore, to show an actual industrial environment, we conducted the cleaning process on a 12-inch PECVD chamber, which is production-level equipment, and quantitatively analyzed the effects of each variable. Power, Pressure, and NF3 Flow all had P-values close to 0, indicating strong statistical significance. The weight for Flow is 15.68, and the weights for Power and Pressure are 4.45 and 5.24, respectively, showing effects 3 and 7 times greater than those with the 6-inch equipment on the cleaning rate. Additionally, we analyzed the cleaning Stdev and derived that there is a trade-off between increasing the cleaning Rate and reducing the cleaning Stdev.

  • PDF

Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems (지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토)

  • Hong, Dong-Seok;Jeong, Chae-Gyun;Lee, Jong-Beom;Seo, Jae-Ho;Jo, Han-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.

Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System (비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템)

  • Chung, Sang-Gi;Kwon, Sam-Young;Jung, Ho-Sung;Kim, Ju-Rak
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.

Development of Process Model for Turbine Control Valve Test in a Power Plant (발전소 터빈제어 밸브시험 계통 모델 개발)

  • Woo, Joo-Hee;Choi, In-Kyu;Park, Doo-Yong;Kim, Jong-An
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.830-837
    • /
    • 2011
  • A turbine control system which has been operated for years in a nuclear power plant was retrofitted with a newly developed digital control system. After completion of the retrofit, turbine valve tests were performed to ensure the integrity of each valve's control function. The sequence of each valve test is composed of a closing process and a reopening process. To minimize megawatt variation which normally occurs during the test sequence, we employed a kind of compensator algorithm in the new digital control system which also have been used in the old system. There were difficulties finding optimal parameter settings for our new compensator algorithm because the power plant didn't allow us to perform necessary tuning procedures while the turbine is on load operation. Therefore an alternative measure for the compensator tuning which is independent of the turbine actual operation had to be implemented. So, a process model for the test was required to overcome this situation. We analyzed the operation data of the test and implemented the process model by use of input and output variable relations. Also we verified the process model by use of another condition's operating data. The result shows that the output of model is similar to the actual operation data.

Evaluation of Nuclear Plant Cable Aging Through Condition Monitoring

  • Kim, Jong-Seog;Lee, Dong-Ju
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.475-484
    • /
    • 2004
  • Extending the lifetime of a nuclear power plant [(hereafter referred to simply as NPP)] is one of the most important concerns in the global nuclear industry. Cables are one of the long-life items that have not been considered for replacement during the design life of a NPP. To extend the cable life beyond the design life, it is first necessary to prove that the design life is too conservative compared with actual aging. Condition monitoring is useful means of evaluating the aging condition of cable. In order to simulate natural aging in a nuclear power plant. a study on accelerated aging must first be conducted. In this paper, evaluations of mechanical aging degradation for a neoprene cable jacket were performed after accelerated aging under tcontinuous and intermittent heating conditions. Contrary to general expectations, intermittent heating to the neoprene cable jacket showed low aging degradation, 50% break-elongation, and 60% indenter modulus, compared with continuous heating. With a plant maintenance period of 1 month after every 12 or 18 months operation, we can easily deduce that the life time of the cable jacket of neoprene can be extended much longer than extimated through the general EQ test. which adopts continuous accelerated aging for determining cable life. Therefore, a systematic approach that considers the actual environment conditions of the nuclear power plant is required for determining cable life.

A Study on the Information Search Behavior Emphasis on the Self-image and Benefit - (의복 구매시 정보 탐색 활동에 관한 연구 -자아 이미지와 추구 편익을 중심으로-)

  • 임경복
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 1998
  • The purpose of this study was to identify the factors which explain consumer's information search behavior. Data were analyzed by utilizing factor analysis and multiple-regression to investigate the relationship among information sources, benefit, and actual and ideal self- image and demographics. Based on the results, information sources for benefit, actual and ideal self-image were developed. Predictors of information sources, benefits, and self-image were identified. Marketing implication about information sources were discussed. The results were as follows. 1. Actual and ideal self-images and information sources were devised into three factors. And benefits were devised into five factors. 2. Actual self-image has more predicting power than ideal self-image to the benefits which consumer sought. Among five benefits, character pursuit was the best predicted factor according to the self-image. 3. Among three information sources, mass communication was the most effective source which can be explained by the benefit and self-image. Fashion pursuit factor was the most significant factor to the mass communication oriented source.

  • PDF

Power : A Concept Analysis for Nursing Research. (간호연구를 위한 권력(POWER)의 개념분석)

  • Byun Young Soon
    • Journal of Korean Public Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.37-44
    • /
    • 1991
  • This paper follows the Walker of Avant approach to concept analysis of the concept of power. For the purposes of the paper, power was defined as the actural or potential ability or capacity to achieve objectives through an interpersonal process in which the goals and means to achieve the goals are mutually established and worked toward. The distinction between the view of power as 'power to' versus 'power over' are addressed in the literature review. King's conceptual framework was used as a guide. The defining attributes of power are: 1. The actual or potential ablity or capacity to achieve objectives or attain goals. 2. An Interpersonal process, 3. Mutual establishment of goals and the means to achieve the goals and 4. Mutually working toward the goals. The antecedents for power were idntified in the literature review: 1. the presence of two or more people 2. acquisition of power skill 3. possession of the power sources 4. an orientation of power as good and 5. self-confidence. The concequences of power are the achievement of objectives or goal attainment. Finally Assumptions and testable hypothesis are proposed.

  • PDF