• Title/Summary/Keyword: Actual Assessment

Search Result 1,174, Processing Time 0.024 seconds

Development of Near miss Assessment Model Using Bayesian Network and Derivation of Major Causes (베이지안 네트워크를 이용한 아차사고 평가 모델 개발 및 주요 원인 도출)

  • Seon Yeong Ha;Mi Jeong Lee;Jong-Bae Baek
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.54-59
    • /
    • 2023
  • The relationship between near misses and major accidents can be confirmed using the ratios proposed by Heinrich and Bird. Systematic reviews of previous national and international studies did not reveal the assessment process used in near-miss management systems. In this study, a model was developed for assessing near misses and major factors were derived through case application. By reviewing national and international literature, 14 factors were selected for each dimension of the P2T (people, procedure, technology) model. To identify the causal relationship between accidents and these factors, a near-miss assessment model was developed using a Bayesian network. In addition, a sensitivity analysis was conducted to derive the major factors. To verify the validity of the model, near-miss data obtained from the ethylene production process were applied. As a result, "PE2 (education)," "PR1 (procedure)," and "TE1 (equipment and facility not installed)" were derived as the major factors causing near misses in this process. If actual workplace data are applied to the near-miss assessment model developed in this study, results that are unique to the workplace can be confirmed. In addition, scientific safety management is possible only when priority is given through sensitivity analysis.

Development for Life Assessment System for Pipes of Thermal Power Plants

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Doo-Young;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.583-588
    • /
    • 2016
  • The high-temperature steam pipes of thermal power plants are subjected to severe conditions such as creep and fatigue due to the power plant frequently being started up and shut down. To prevent critical pipes from serious damage and possible failure, inspection methods such as computational analysis and online piping displacement monitoring have been developed. However, these methods are limited in that they cannot determine the life consumption rate of a critical pipe precisely. Therefore, we set out to develop a life assessment system, based on a three-dimensional piping displacement monitoring system, which is capable of evaluating the life consumption rate of a critical pipe. This system was installed at the "M" thermal power plant in Malaysia, and was shown to operate well in practice. The results of this study are expected to contribute to the increase safety of piping systems by minimizing stress and extending the actual life of critical piping.

A Study of Assessment on Occupational Noise Environment for Metal Working Facility (절삭설비의 소음환경평가에 관한 연구)

  • 이내우;허현철;전성균;이진우
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.457-464
    • /
    • 1999
  • To develop managing guidance of occupational noise exposure for metal working facility, we have studied about drafting contour map of noise exposure, methods of noise assessment and actual calculation method of time weighted noise exposure. Therefore we have suggested that contour maps of noisy workplace are very important for controlling metal working fluid facility and two kinds of noise assessment method, so called, personal andstatic exposure are necessary to avoid argument between workers and managing group. Finally we would like recommend that the Korean specification of noise exposure should be modified to protect ONIHL(oocupational noise induced hearing loss).

  • PDF

Assessment of Lightning Arrester Location in Combined Transmission Line Connected whth Overhead Line and Underground Cable (가공송전선로와 지중송전선로가 연계된 혼합송전선로에서 피뢰기 적정위치 검토 및 평가)

  • Ha, Che-Wung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.443-445
    • /
    • 2000
  • This paper describes the assessment of proper location of lightning arrester in combined transmission line which is connected with overhead line and underground cable. The modeling for simulation is established using the actual system in ATP Draw and EMTP. Simulation is carried out to find out the best point to install the arrester in given the model system. And also voltage and current is analyzed on cable covering protection unit(CCPU). The simulation result demonstrated the best location of arrester in the given transmission line through the detailed analysis and its assessment.

  • PDF

Life Cycle Assessment (LCA) on Sludge Treatment System (Life Cycle Assessment(LCA)를 도입(導入)한 오니처리(汚泥處理)시스템의 평가(評價))

  • Hwang, Yong-Woo;Kwon, Bong-Kee;Ryu, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.50-64
    • /
    • 1997
  • Life cycle assessment (LCA) on total sewage sludge treatment system from thickening to incineration and melting was performed for estimating global environmental impact as $CO_2$. In general, the life cycles of actual treatment facilities consist of construction, operation and dismantlement. In this study, the amount of $CO_2$ produced from both whole and each life cycle step of currently used unit sludge treatment processes were calculated by inventory analysis. In addition, in the all processes investigated in this study, individual $CO_2$ production unit (CPU), i.e. total produced $CO_2$ by treating a unit weight of sludge was also calculated. By using the CPU matrix of the unit processes, it was possible to simulate the $CO_2$ production for any type of complex-system as well as to trace a dominant cause of $CO_2$ production in each process. Four selected alternatives examined here, each involve the same disposal way but differ substantially in the $CO_2$ exhaust.

  • PDF

Evaluation of Appropriate Management of Chronic Obstructive Pulmonary Disease in Korea: Based on Health Insurance Review and Assessment Service (HIRA) Claims

  • Chung, Sang Mi;Lee, Sung Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.3
    • /
    • pp.241-246
    • /
    • 2017
  • Chronic obstructive pulmonary disease (COPD) is an ambulatory care-sensitive condition, and effective treatment of outpatients can prevent worsening of the illness and hospitalization. Current COPD guidelines provide appropriate guidance for the diagnosis and treatment of patients with COPD. In fact, it has been shown that when appropriate guidance and treatment are performed, the morbidity and mortality rates of COPD patients are reduced. However, there is a gap between the clinical guidelines and the actual clinical treatment. Therefore, the Health Insurance Review and Assessment Service (HIRA) conducted an evaluation of the adequacy of COPD diagnosis and treatment using the Claims Database of HIRA. This review provides a summary of the COPD adequacy assessment results reported by the HIRA and some brief comments on the results.

A Strategy of Refrigerator Noise Control by Using Subjective Assessment (주관적 평가방법을 적용한 냉장고 소음대책 수립)

  • 정광일;김석관;이종구;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.191-196
    • /
    • 2001
  • The conventional methods for noise control attempts to simply reduce the level of product noise. This has been common practice in noise control industry. However, it is very straightforward common sense that we have consider human perception on noise. In this paper, we propose a noise control strategy which takes into account the subjective perception of product noise. We especially has concentrated on a refrigerator noise. The proposed method is composed of 3 steps. Firstly, the actual refrigerator noise signal is measured. Then, to make the sample noise set for subjective assessment the noise signal is edited in 1/3 octave bands. Finally, we establish a strategy of refrigerator noise control by using the results from subjective assessment of these noise signals

  • PDF

Probabilistic Risk Assessment Techniques for the Risk Analysis of Construction Projects (건설공사의 위험도분석을 위한 확률적 위험도 평가)

  • 조효남;임종권;박영빈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.27-34
    • /
    • 1997
  • In this paper, systematic and comprehensive approaches are suggested for the application of quantitative PRA techniques especially for those risk events that cannot be easily evaluated quantitatively In addition, dominant risk events are identified based on their occurrence frequency assessed by both actual survey of construction site conditions and the statistical data related with the probable accidents. Practical FTA(Fault Tree Analysis) and ETA(Event Tree Analysis) models are used for the assessment of the identified risks. When the risk events are lack of statistical data, appropriate Bayesian models incorporating engineering judgement and test results are also introduced in this paper. Moreover, a fuzzy probability technique is used for the quantitative risk assessment of those risk components which are difficult to evaluate quantitatively.

  • PDF

Safety Management Information System in Bridges Construction Work (교량 건설공사의 안전관리정보시스템 개발)

  • Park, Jong-Keun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.73-80
    • /
    • 2011
  • There are insufficient models that find problems and solutions for accident prevention through risk assessment and suggest safe work process and work instruction from foundation works to finish work for accident decrease. This paper presents a quantitative risk assessment model by analysis of risk factors in each process such as foundation, erection, pier, pier upper and etc based on accident examples and investigation on actual condition in bridges construction work. In addition, the safety management system was developed to perform risk assessment of construction and use it for effective safety training for labor.

Representative Rating of Bridges using Condition Assessment Data (상태평가 결과를 이용한 교량의 대표등급 산정방법)

  • Oh, Byung-Hwan;Kim, Kwang-Soo;Shin, Kyung-Joon;Lee, Sang-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 2002
  • Currently, the inspection of bridges is conduced for the parts or elements of a bridges and the results of inspection are depicted for those local elements. Therefore, the representative rating of a bridge as a whole bridge system is not presented. The purpose of the present study is to purpose a reasonable method which can yield realistic representative rating for an actual bridge. The purpose method consists of two steps, i.e, visual inspection step and safety assessment step. The importance of members is considered by introducing the weighting factors and the number of spans is also considered to obtain the representative rating of a whole bridge system. The purpose method may be efficiently used to calculate the realistic representative rating bridge structures.