• Title/Summary/Keyword: Activity removal rate

Search Result 196, Processing Time 0.026 seconds

A Study on the Reduction Process of VOCs Emission from Paint Booth - A Hybrid Process of Biotrickling Filter and Activated Sludge Reactor

  • Lim Gye-Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.41-48
    • /
    • 2005
  • A novel hybrid system composed of a biotrickling filter and an activated sludge reactor was investigated under the conditions of four different SRTs (sludge retention times). The performance of the hybrid reactor was found to be directly comparable among the four different sludge ages. Discernible differences in the removal performance were observed among four different SRTs of 2, 4, 6, and 8 days. High removal efficiency was achieved by continuous circulation of activated sludge over the immobilized mixture culture, which allowed on pH control, addition of nutrients, and removal of paint VOCs (volatile organic compounds). The results also showed that the removal efficiency for a given pollutant depends on the activity of microorganisms based on the SRT. As the SRT increased gradually from 2 to 8 days, the average removal performance decreased. The highest removal rate was achieved at the SRT of 2 days at which the highest OUR (oxygen uptake rate), $6.1mg-O_2/liter-min$ was measured. Biological activity in the recycle microbes decreased to a much lower level, $3.6mg-O_2/liter-min$ at a SRT of 8 days. It is thus believed that young microorganisms were more active and more efficient for the VOCs removal of low concentrations and high flow rates. The apparent correlation of $R^2=0.996$ between the average removal efficiency and the average OUR at each SRTs suggests that VOCs degradation by young cells significantly affected the overall removal efficiency for the tested SRTs.

Effects on Microbial Activity of Aerobic Granular Sludge (AGS) in High-Salinity Wastewater (고농도 염분함유 폐수가 호기성 그래뉼 슬러지의 미생물 활성도에 미치는 영향)

  • Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.7
    • /
    • pp.629-637
    • /
    • 2019
  • The purpose of this study was to evaluate the effect of high-salinity wastewater on the microbial activity of Aerobic Granule Sludge (AGS). Laboratory-scale experiments were performed using a sequencing batch reactor, and the Chemical Oxygen Demand (COD), nitrogen removal efficiency, sludge precipitability, and microbial activity were evaluated under various salinity injection. The COD removal efficiency was found to decrease gradually to 3.0% salinity injection, and it tended to recover slightly from 4.0%. The specific nitrification rate was 0.043 - 0.139 mg $NH_4{^+}-N/mg$ $MLVSS{\cdot}day$. The specific denitrification rate was 0.069 - 0.108 mg $NO_3{^-}-N/mg$ $MLVSS{\cdot}day$. The sludge volume index ($SVI_{30}$) ultimately decreased to 46 mL/g. The specific oxygen uptake rate decreased from an initial value 120.3 to a final value 70.7 mg $O_2/g$ $MLVSS{\cdot}hr$. Therefore, salinity injection affects the activity of AGS, causing degradation of the COD and nitrogen removal efficiency. It can be used as an indicator to objectively determine the effect of salinity on microbial activity.

Study on Change of Microbial Activity and Removal Efficiency of Phosphorus with Alum Injection in the Biological Process (생물학적 처리공정 내 Alum 주입에 따른 인 처리 효율과 미생물 활성도 변화에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.188-193
    • /
    • 2011
  • The effects of coagulants on the microorganisms when they are injected directly into the biological treatment facility for T-P removal have been easily observed from the results of past experiments. As such this study is set out to derive the effective plans for the coagulant dosage by analyzing the effects of the injected coagulant on the microbial activity during the chemical treatment for T-P removal. The research methods entailed the assessment of removal efficiency of T-P according to the coagulant dosage while changing the molar ration between Alum and influent phosphorus. At the same time Specific Oxygen Uptake Rate (SOUR) according to the coagulant dosage was measured. SOUR was used as a method for indirect assessment of the microbial activity according to the coagulant dosage. The results from the study showed that with the increase in the alum dosage, the removal efficiency T-P tended to increase. On the other hand, the increase in coagulant dosage resulted in the decrease in SOUR, which indicates the decrease in the microbial activity. Such reduction in the activity could be explained by the increase in the concentration of removal efficiency of $TBOD_5$. Based on experiment results from the study, it is determined that coagulant dosage affects the microbial activity. Moreover, the indirect assessment on the microbial activity using SOUR is considered possible.

A Study of Removal of Phenol by Peroxidase Extracted from Oenanthe javanica (Blume) DC (미나리 Peroxidase를 이용한 Phenol제거에 관한 연구)

  • 탁창준;최한영;신정식;나규환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.121-126
    • /
    • 1997
  • Peroxidase as one of the organic enzyme catalyst is useful for the oxidation treatment of various aromatic compounds such as phenols. The peroxidase content of Oenanthe javanica was 24.85 unit/g-fw in leaf, 5.74 unit/g-fw in stem, and 34.69 unit/g-fw in root respectively. The crude peroxidase extracted from Oenanthe javanka can be kept under low temperature (-70$\circ$C) condition for 6 months with the maximum 1% activity reduction. The optimum conditions of removal for 100 ppm phenol was pH 6, hydrogen peroxide 3.5 mM, peroxidase activity 8 unit/ml, temperature 20$\circ$C respectively. In the wide range of concentration from 50 ppm to 750 ppm phenol reveals average 54% removal rate under the same peroxidase activity (8 unit/ml) and different amount of hydrogen peroxide proportional to phenol concentration. Especially at the concentration of 100 ppm the maximum phenol removal rate was 72%.

  • PDF

The Study on the Remediation of Contaminated Soil as TPH using SVE and Bioremediation (SVE 및 생물학적 공법을 이용한 TPH 오염토양처리에 관한 연구)

  • Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2008
  • This study examined the contaminated soils with an indicator of TPH using SVE (Soil Vapor Extraction) and biological treatments. Their results are as follows. Water content in the polluted soils slowly decreased from 15% during the initial experimental condition to 10% during the final condition. Purification of polluted soils by Bioventing system is likely to hinder the microbial activity due to decrease of water content. Removal rate of TPH in the upper reaction chamber was a half of initial removal rate at the 25th day of the experiment. The removal rate in the lower reaction chamber was 45% with concentration of 995.4 mg/kg. When the Bioventing is used the removal rate at the 14th day of the experiment was 53%, showing 7 day shortenting. Since the Bioventing method control the microbial activity due to dewatering of the polluted soil, SVE method is likely to be preferable to remove in-situ TPH. The reactor that included microbes and nutrients showed somewhat higher removal rate of TPH than the reactor that included nurtients only during experimental period. In general, the concentration showed two times peaks and then decreased, followed by slight variation of the concentration in low concentration levels. Hence, in contrast to SVE treatment, the biological treatment tend to show continuous repetitive peaks of concentration followed by concentration decrease.

Characteristics of Immobilized PVA Beads in Nitrate Removal

  • Cho Kyoung-Sook;Park Kyoung-Joo;Jeong Hyun-Do;Nam Soo-Wan;Lee Sang-Joon;Park Tae-Joo;Kim Joong-Kyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.3
    • /
    • pp.414-422
    • /
    • 2006
  • Before applying PVA bio-beads to practical biological treatment of nitrate-containing wastewater, their characteristics were examined. PVA bio-beads could steadily produce nitrogen gas from nitrate for 28 batches with 0.04 ml/l/h of the maximum gas production rate; however, the maximum gas production rate dropped remarkably thereafter with apparent deformation of beads. Addition of 2.2% solution containing 1% casamino acid, 1% yeast extract, 0.1% mineral solution, and 0.1% vitamin solution to the culture medium resulted in not only recovery of activity of deactivated beads, but also a higher rate of gas production. Calculation of economic benefit for the use of bio-beads in a long-run operation indicated that reactivation of bio-beads by chemicals had economical advantages over packing new bio-beads in the system. The continuously stirred bioreactor exhibited a satisfactory performance at HRT of 20.0 h. With a 9.5 mg $NO_{3}^{-}N/l/h$ nitrate removal rate, nitrate could completely be removed without nitrite accumulation. The use of PVA bio-beads in nitrate removal appears very promising.

Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area (인공습지에 의한 농촌오수처리에 관한 연구)

  • 윤춘경;권순국;김형중
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

Effect of Chlorination for Bulking Control on the Organic Removal Activity of Activated Sludge Treating Dairy Wastewater (유가공 폐수의 활성슬러지 처리에서 벌킹 제어용 염소가 미생물의 유기물 분해 활성에 미치는 영향)

  • Nam Se-Yong;Choi Jin-Taek
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.96-101
    • /
    • 2006
  • Chlorination inhibition on the organic removal activity of activated sludge microorganism was investigated in this study. It is well known that chlorination improves the settleability of filamentous bulking sludge through the selective impediment of filamentous microorganisms. However, it is based on the declination of effluent water quality after actual chlorination in dairy wastewater treatment plant. In case of the activated sludge which was exposed in the suggested concentration of chlorine $7.5\;mgCl_2/gVSS/day$ for the filamentous bulking control, decrease of organic uptake rate of $4.9\~24.0\%$, and dentrification rate of $24.8\~30.3\%$ ware shown in comparison to the control group which was not reacted with chlorine. As a result of comparing floc size of activated sludge microorganism, the average of floc diameter in the chlorine exposed group was $150\;{\mu}m$, which displays $25\%$ decrease compared with the control group.

A Study on the Removal Characteristics of Dissolved Organic and Ammonia Compounds in PFR of Aerated Submerged Bio-film (ASBF) Reactor (PFR 공정의 ASBF 구조에 의한 유기물제거와 질산화의 영향에 대한 연구)

  • Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1265-1271
    • /
    • 2008
  • Aerated submerged bio-film (ASBF) pilot plant has been developed. The presented studies optimized an inexpensive method of enhanced wastewater treatment. The objectives of this research were to describe pilot scale experiments for efficient removal of dissolved organic and nitrogen compounds by using ASBF reactor in plug-flow reactor (PFR) and improve understanding of dissolved organic matter and nitrogen compounds removal rates with dynamic relationships between heterotrophs and autotrophs in the fixed-film reactor. This research explores the possibility of enhancing the performance of shallow wastewater treatment lagoons through the addition of specially designed structures. This direct gas-phase contact should increase the oxygen transfer rate into the bio-film, as well as increase the micro-climate mixing of water, nutrients, and waste products into and out of the bio-film. This research also investigated the efficiency of dissolved organic matter and ammonia nitrogen removals in the ASBF. As it was anticipated, nitrification activity was highest during periods when the flow rate was lower, but it seemed to decline during times when the flow rate was highest. And ammonia nitrogen removal rates were more sensitive than dissolved organic matter removal rates when flow rates exceeded 2.2 L/min.

Effects on Microbial Activity and Substrate Removal in Industrial Wastewater with Fluoride Content (산업폐수에서 불소함유가 미생물활성도 및 기질제거에 미치는 영향에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong;Jin, Oh Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.717-722
    • /
    • 2012
  • Fluoride can be easily found in semiconductor and display industry. However, there is a lack of research for its effects on the related wastewater treatment. The objective of this study is to evaluate the microbial inhibitory effect by fluoride injection. The research entailed the assessment of removal efficiency of $TCOD_{Cr}$ according to the fluoride concentration and also the Specific Oxygen Uptake Rate (SOUR) was measured. The laboratory scale reactor was prepared and operated with the fluoride concentrations of 0, 10, 50, 100, and 200 mg/L based on concentrations frequently occurring in the wastewater. The results from this study showed that, as the fluoride concentration increase, the Specific Substrate Utilization Rate (SSUR) tend to decrease as expected. Also, the increase in fluoride concentrations resulted in the decrease in SOUR. It is determined that fluoride injection affects the microbial activity. Especially, The addition of above 200 mg/L fluoride into reactor caused rapidly decreased SSUR and SOUR due to the inhibitory effects of fluoride.