• Title/Summary/Keyword: Activity Monitor

Search Result 366, Processing Time 0.031 seconds

Zigbee Based Wireless Respiration Monitor System (지그비 통신 기반의 근거리 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.142-147
    • /
    • 2008
  • Abdominal circumference changes due to breathing by the respiratory muscle activity such as diaphragm, which would partially represent the lung volume variation. The present study introduced conductive rubber molded in a cord shape incorporated with a patient's pants. The conductive rubber cord operated as a displacement transducer to measure the lung or abdominal volume changes. Signal extraction circuitry was developed to obtain the volume and its derivative(or the flow) signals followed by wireless transmission based on the Zigbee communication protocol in a size of $65mm{\times}105mm$ easily put in pocket. Breathing frequency was accurately evaluated and breath pattern analysis seemed feasible, since respiratory behaviours such as maximal inspiration and cough were well identified. Remote wireless receiver module also enabled to monitor both volume and flow signals during resting breathing on a PC terminal.

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

Differential Activation of Arabidopsis Cab Promoters during Greening of Transgenic Tobacco Shoots (형질전환된 담배 어린 싹의 녹화과정 중 Arabidopsis Cab 프로모터의 활성 차이)

  • 이춘환
    • Journal of Plant Biology
    • /
    • v.36 no.3
    • /
    • pp.267-273
    • /
    • 1993
  • Promoters of the chlorophyll a/b bidning protein genes, cab1, and cab2, of Arabidopsis thaliana were studied for their functions in differential expression during greening of etiolated shoots. The etiolated shoots were derived from leaves of transgenic tobacco plants with the cab-CAT (chloramphenicol acetyltransferase) translational fusions, and CAT activity was measured to monitor the activities of the cab promoters. Cab1 promoter activity increased rapidly and showed saturation after about 24 hours of greening, but that of cab2 increased with about 2 day-lag period and showed saturation after 6 days. Cab1 promoter activity was more sensitive to levulinic acid (LA) compared with cab2 activity. Cab2 promoter activity was inhibited more sensitively by chloramphynicol (CAP) than by inhibitors of Chl formation. Cab1 promoter activity was, however, inhibited less sensitively by CAP than by LA. The treatment of abscisic acid (ABA) did not block Chl synthesis so significantly as LA treatment did, and cab2 promoter activity was much less sensitive to ABA compared with that of cab1. These results suggest that cab1 expression is strongly related with Chl formation, possibly with $\delta$-aminolevulinic acid accumulation, and cab2 expression is suppressed more by the blockage of translation of Chl a-apoproteins than by the blockage of Chl a accumulation.

  • PDF

Policy proposal for monitoring of evidence-based physical activity projects (근거-기반의 신체활동사업 모니터링을 위한 정책 제안)

  • Kim, Wan-Soo;Lee, Mi-Ra
    • Korean Journal of Health Education and Promotion
    • /
    • v.32 no.1
    • /
    • pp.67-76
    • /
    • 2015
  • Objectives: This study performed to verify Korea National Health and Examination Survey(KNHAES) to monitor recommended physical activity(PA) and to propose an monitoring tools for evidence-based PA projects. Methods: The characteristics of the Global Physical Activity Questionnaire(GPAQ) and its reliability and validity were overviewed based on the current scientific evidence in the field of PA. Relevant articles were identified through multiple sources including PubMed, Science Direct, Scopus, CINAHL, ASP, RISS4U, and KISS. Results: The GPAQ has strong points over the Short Form of International Physical Activity Questionnaire(IPAQ-SF) as a monitoring tool to meet recommended PA levels for three domains separately and reflecting a better understanding about walking. Its reliability and validity also were reported as acceptable in existing studies overall. Some limitations of this questionnaire, however, need to be addressed to improve its quality. Conclusions: For monitoring of evidenced-based physical activity projects, we considered that it is able to be provided an opportunity for in-depth discussion among academic experts and policy-makers about the necessity of complements for KNHAES and applying new tools, and it could be the basis for development of physical activity monitoring tool in the future.

The Analysis of the Activity Patterns of Dog with Wearable Sensors Using Machine Learning

  • Hussain, Ali;Ali, Sikandar;Kim, Hee-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.141-143
    • /
    • 2021
  • The Activity patterns of animal species are difficult to access and the behavior of freely moving individuals can not be assessed by direct observation. As it has become large challenge to understand the activity pattern of animals such as dogs, and cats etc. One approach for monitoring these behaviors is the continuous collection of data by human observers. Therefore, in this study we assess the activity patterns of dog using the wearable sensors data such as accelerometer and gyroscope. A wearable, sensor -based system is suitable for such ends, and it will be able to monitor the dogs in real-time. The basic purpose of this study was to develop a system that can detect the activities based on the accelerometer and gyroscope signals. Therefore, we purpose a method which is based on the data collected from 10 dogs, including different nine breeds of different sizes and ages, and both genders. We applied six different state-of-the-art classifiers such as Random forests (RF), Support vector machine (SVM), Gradient boosting machine (GBM), XGBoost, k-nearest neighbors (KNN), and Decision tree classifier, respectively. The Random Forest showed a good classification result. We achieved an accuracy 86.73% while the detecting the activity.

  • PDF

Inequality and Entrepreneurial Activity (불평등과 기업가적 활동의 관계 연구)

  • Hwang, Byung ho;Kim, Do hyeon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.3
    • /
    • pp.1-12
    • /
    • 2018
  • This study attempts to identify the relationship between inequality and entrepreneurship activities and to provide theoretical and policy implications. To do this, we use the Global Entrepreneurship Monitor (GEM), which is a survey of entrepreneurial activities at the national level, the World Income Inequality Database (WIID), and the World Bank survey data. The analysis shows entrepreneurial activities are relatively high in countries with high level of inequality. We also find GDP moderates the relationship between inequality and entrepreneurial activity. In addition, as expected, necessity entrepreneurship prevails in low income group while opportunity entrepreneurship is dominant in high income group. The study illustrates potential venue for research of entrepreneurship and inequality, whiles calls for broader studies and scrutiny.

Development of an INS Integrated Positioning System for Assisting Effective Fire-fighting Activity

  • Suh, Yong-Cheol;Kumagai, Hideo;Konishi, Yusuke;Shibasaki, Ryosuke
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.946-948
    • /
    • 2003
  • This paper describes the development of an INS (Inertial Navigation System) integrated positioning system, which can monitor and track the firefighter's position for assisting effective fire-fighting activity and rescue services. The INS consists of highly accurate three-axis gyro sensor and three-axis accelerometer. By integrating an INS to positioning system, it is also possible to obtain the information of firefighter's physical state (e.g. standing, collapse and crouch) of posture including velocity. Consequently, this research would obviously make a contribution to effective rescue activities and safety of firefighters. Besides, this paper presents results from field tests conducted at Tokyo University demonstrating its viability and utility. We also summarize the overall system requirements and architecture, and describe the hardware and software used in the prototype system in detail.

  • PDF

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Potentiometric Homogeneous Enzyme-Linked Binding Assays for Riboflavin and Riboflavin Binding Protein

  • 김진목;김혜진;김미정;이동주;한상현;차근식
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.1018-1022
    • /
    • 1996
  • Adenosine deaminase (ADA) has been utilized as the label in devising a potentiometric homogeneous assay for riboflavin and riboflavin binding protein (RBP). The proposed homogeneous assay method employs an ADA-biotin conjugate as the signal generator and an avidin-riboflavin conjugate as the signal modulator in the solution phase. The catalytic activity of the ADA-biotin conjugate is inhibited in the presence of an excess amount of the avidin-riboflavin conjugate, and the observed inhibition is reversed in an amount proportional to the concentration of RBP added. When the analyte riboflavin is added to this mixture of ADA-biotin, avidin-riboflavin and RBP, the activity of the enzyme conjugate is re-inhibited in an amount proportional to the concentration of riboflavin. Since the enzyme label used in this system is ADA, an ammonia-producing enzyme, a potentiometric rather than photometric detection scheme is used to monitor the enzymatic activity in the assay.

Health and Wellness Monitoring Using Intelligent Sensing Technique

  • Meng, Yao;Yi, Sang-Hoon;Kim, Hee-Cheol
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.478-491
    • /
    • 2019
  • This work develops a monitoring system for the population with health concerns. A belt integrated with an on-body circuit and sensors measures a wearer's selected vital signals. The electrocardiogram sensors monitor heart conditions and an accelerometer assesses the level of physical activity. Sensed signals are transmitted to the circuit module through digital yarns and are forwarded to a mobile device via Bluetooth. An interactive application, installed on the mobile device, is used to process the received signals and provide users with real-time feedback about their status. Persuasive functions are designed and implemented in the interactive application to encourage users' physical activity. Two signal processing algorithms are developed to analyze the data regarding heart and activity. A user study is conducted to evaluate the performance and usability of the developed system.