• Title/Summary/Keyword: Active type method

Search Result 572, Processing Time 0.024 seconds

Visualization for the mixing state of a batch-type ultrasonic mixer for its application to the microdevice (마이크로믹서에의 응용을 위한 batch type 초음파믹서의 혼합 상태 가시화)

  • Heo, Pil-Woo;Yoon, Eui-Soo;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • An active ${\mu}$-mixer is important in Bio-MEMS and ${\mu}$-TAS. The mixing state depends on some kinds of factors including the intensity of ultrasonic radiation. We have visualized the mixing state of the mixing chamber with radiation time and presented the influence of the driving voltage in this research. It will be possible to compare the performances of the ultrasonic radiation parts used in the active ${\mu}$-mixer using this method.

Active control for Seismic Response Reduction using Modal-fuzzy Approach (모달 퍼지 이론을 이용한 지진하중을 받는 구조물의 능동제어)

  • Choi, Kang-Min;Cho, Sang-Won;Oh, Ju-Won;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.409-416
    • /
    • 2004
  • An active modal-fuzzy control method using hydraulic actuators is presented for seismic response reduction. In the proposed control system, a new fuzzy controller designed in the modal space produces the desired active control force. This type controller has all advantages of the fuzzy control algorithm and modal approach. Since it is very difficult to select input variables used in fuzzy controller among an amount of state variables in the active fuzzy control system the presented algorithm adopts the modal control algorithm which is able to consider more easily information of all state variables in civil structures that are usually dominated by first few modes. In other words, all information of the whole structure can be considered in the control algorithm evaluated to reduce seismic responses and it can be efficient for especially civil structures. In addition, the presented algorithm is expected to magnify utility and performance caused by efficiency that the fuzzy algorithm can handle complex model more easily. An active modal-fuzzy control scheme is applied together with a Kalman filter and a low-pass filter to be applicable to real civil structures. A Kalman filter is considered to estimate modal states and a low-pass filter was used to eliminate spillover problem. The results of the numerical simulations far a wide amplitude range o f loading conditions and for historic earthquakes having various frequency components show that the proposed active modal-fuzzy control system can be beneficial in reducing seismic responses of civil structures.

  • PDF

Expression of the Pro-Domain-Deleted Active Form of Caspase-6 in Escherichia coli

  • Lee, Phil Young;Cho, Jin Hwa;Chi, Seung Wook;Bae, Kwang-Hee;Cho, Sayeon;Park, Byoung Chul;Kim, Jeong-Hoon;Park, Sung Goo
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.5
    • /
    • pp.719-723
    • /
    • 2014
  • Caspases are a family of cysteine proteases that play an important role in the apoptotic pathway. Caspase-6 is an apoptosis effector that cleaves a variety of cellular substrates. The active form of the enzyme is required for use in research. However, it has been difficult to obtain sufficient quantities of active caspase-6 from Escherichia coli. In the present study, we constructed a caspase-6 with a 23-amino-acid deletion in the pro-domain. This engineered enzyme was expressed as a soluble protein in E. coli and was purified using affinity resin. In vitro enzyme assay and cleavage analysis revealed that the engineered active caspase-6 protein had characteristics similar to those of wild-type caspase-6. This novel method can be a valuable tool for obtaining active caspase-6 that can be used for screening caspase-6-specific substrates, which in turn can be used to elucidate the function of caspase-6 in apoptosis.

Active control for Seismic Response Reduction using Modal-fuzzy Approach (모달 퍼지 이론을 이용한 지진하중을 받는 구조물의 능동제어)

  • Choi, Kang-Min;Park, Kyu-Sik;Kim, Chun-Ho;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.513-520
    • /
    • 2005
  • An active modal-fuzzy control method using hydraulic actuators is presented for seismic response reduction. In the proposed control system, a new fuzzy controller designed in the modal space produces the desired active control force. This type controller has all advantages of the fuzzy control algorithm and modal approach. Since it is very difficult to select input variables used in fuzzy controller among an amount of state variables in the active fuzzy control system, the presented algorithm adopts the modal control algorithm which is able to consider more easily information of all state variables in civil structures that are usually dominated by first few modes. In other words, all information of the whole structure can be considered in the control algorithm evaluated to reduce seismic responses and it can be efficient for especially civil structures. In addition, the presented algorithm is expected to magnify utility and performance caused by efficiency that the fuzzy algorithm can handle complex model more easily. An active modal-fuzzy control scheme is applied together with a Kalman filter and a low-pass filter to be applicable to real civil structures. A Kalman filter is considered to estimate modal states and a low-pass filter was used to eliminate spillover problem. The results of the numerical simulations for a wide amplitude range of loading conditions show that the proposed active modal-fuzzy control system can be beneficial in reducing seismic responses of civil structures.

  • PDF

A Prediction of the Static and Dynamic Horizontal Active Thrusts Exerted by a Backfill Consisting of Two or Three Layers of Different Properties (2종류 또는 3종류의 흙으로 뒷채움이 구성될 경우의 정적 및 동적 수평주동토압합력 예측)

  • Kim, Hong Taek;Kang, In Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.65-76
    • /
    • 1991
  • A numerical solution method for the evaluation of the static and dynamic horizontal active thrusts exerted by a backfill, consisting of two or three layers of different properties, on a retaining wall is proposed in the present study based on the Mononobe-Okabe analysis. Using the proposed method, the efficient type in forming a backfill with two layers of different properties is analyzed. In addition, for the design examples of a backfill made up of two or three layers of different properties, the static and dynamic horizontal active thrusts computed using the soil property of each layer are compared with those obtained from the proposed method, and also the problems expected in design are presented based on the comparisons.

  • PDF

Analysis on Current Characteristics According to Injection Method and Driving Waveform in Electrophoretic-Type E-Paper Display (전기영동형 전자종이 디스플레이에서 전자잉크의 주입 방법 및 구동파형에 따른 전류 특성 분석)

  • Lee, Joo-Won;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.386-392
    • /
    • 2020
  • In this study, the drift current characteristics of charged particles are analyzed for panels fabricated by varying the waveform biasing of the active particle loading method (APLM), which is a method driven by the electrophoretic principle of loading charged particles into a cell of a barrier rib-type electronic paper. We prepare 3 panels using APLM and 1 panel without APLM. The waveform of APLM uses square wave and ramp wave, and the step voltage wave is applied to the driving voltage. The drift currents measured from the square wave and ramp wave with the same period applied by APLM are 4.872 µC and 5.464 µC, respectively, and the ramp wave is shown to be relatively advantageous for loading charged particles that have a large q/m. The time-current curve results confirm that the abrupt movement of charged particles is occurring. When the step form wave signal with a short time of 1s is first applied, initial large movement of the charged particles is confirmed to occur in all samples, which is understood as the effect of applying the voltage necessary to remove the imaging force. The results of this study are expected to improve the loading of charged particles into the electronic paper cell, driven by the electrophoretic principle and optimization of the driving conditions.

Visual Inspection System for Irregularly Formed Timing Belt with Low Reflection Ratio (저반사비를 가진 비균질 타이밍 벨트를 위한 자동시각 검사시스템)

  • Lee, Jae-Woo;Yoon, Joong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.1996-2001
    • /
    • 2012
  • Visual inspection systems are widely proposed for the well formed surface materials like electronics parts. But the materials with ill reflection ability have many troubles when visual inspection system is introduced. We have developed a robust visual inspection system that can work well in spite of low reflection ratio and with much noise when truth model is not known in the mixed production line. A workpiece identification technique using k-means has been proposed to identify the type. Based on the identified type, a robust-to-noise segmentation method, called active contour, has been applied to segment the features from the image. Finally, Kalman filter has been applied to adapt the error variation. Experiment shows that performance is about to match the accuracy of manual measurement using projectors.

Study of Characteristics of Corona Discharge Plasma in a Wire-Cylinder Type Reactor (Wire-Cylinder형 반응로에서의 코로나 방전 플라스마의 특성 연구)

  • 박승자;박인호;고욱희
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.132-138
    • /
    • 2004
  • We used the self-consistent one-dimensional model applied to FCT algorithm and FEM method in a wire-cylinder type reactor to study the characteristics of corona discharge plasma in air at the atmospheric pressure. At the pulsed do voltage and do voltage, we studied the changes of the characteristic of plasma by computing electron density profile according to the changes of voltage and the size of reactor. The changes of active radius from this result are compared with the data of Peek's. The numerical simulation results for a corona discharge plasma explain the physical mechanism of the discharge process and could be used to obtain the optimized parameters for designing the plasma reactor for pollution abatement.

Changes in Student Nurses' Perception between Initial and Final Clinical Practice (임상실습 초기와 종료 후의 임상실습에 대안 간호학생의 인식 변화)

  • Kim Myung-Ae;Nam Seung-Hee;Kim Hyo-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.1
    • /
    • pp.21-30
    • /
    • 2004
  • Purpose: The purpose of this study was to explore perception of clinical experience between the initial and final practice and to explore changes in the perception of clinical experience. Method: The study used a Q-method to measure perception of clinical practice. Thirty-six statements made up the finalized Q-sample. The P sample used thirty three nursing college students from K university. The initial collection was done in the first semester of their junior year and second collection was done in the last semester of their senior year. The Q-sorts by each student were coded and analysed with the Quanl PC program. Result: Many students classified as having the perception type 'alienation of ideal and reality' or 'perception of limitation of ability' in the initial clinical practice changed to the type, 'active participation' by the final clinical practice. Further, in the initial clinical practice, part of 'active participation' and 'perception of limitation of ability' changed to 'alienation of ideal and reality'. Conclusion: This study shows that perception of their clinical practice by student nurses changed in a positive direction through clinical experience and that this fact was related to the level of satisfaction with nursing. The knowledge and understanding obtained in this research provide insights for nursing faculty and students involved in nursing education.

  • PDF

A novel control strategy of active power filter type bidirectional UPS (능동필터형 쌍방향 UPS의 새로운 제어기법)

  • Kim, Je-Hong;Yeom, Sang-Ku;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2082-2084
    • /
    • 1997
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system Performance is verified by the simulation and experimental results.

  • PDF