Design and Analysis of Above Knee Prosthetic Leg Using MR Damper (유동모드 MR 댐퍼가 구비된 대퇴의족의 설계 및 해석)

  • Park, Jinhyuk;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.165-171
    • /
    • 2016
  • A prosthetic knee for above-knee (AK) amputee is categorized into passive and active type. The passive prosthetic knee is generally made by elastic material. Although AK amputee can easily walk by using passive prosthetic leg, knee joint motions are not similar to ordinary persons. The active prosthetic leg can control the knee angle owing to the actuator and microprocessor. However, the active type is not cost-effective and the stability may be lost due to the malfunction of sensors. In order to resolve these disadvantages of passive and active type, a semi-active prosthetic knee which can control the knee angle is proposed in this work. The proposed semi-active one requires a less input energy but provides active type performance. In order to achieve this goal, in this work, a semi-active prosthetic knee using magneto-rheological (MR) damper for AK amputees is designed. The MR damper can support the weight of body by using less energy than actuator of active prosthetic. It can control knee angle by inducing the magnetic field at the time of stance phase. This salient characteristic is evaluated and presented in this work.

Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control (Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발)

  • 홍예선;류시복;김영식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.3
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

Comparison of Aldehydes Concentrations Characteristics According to Measurement Methods in Temporary Exhibition Hall (측정방법에 따른 유물전시관 기획전시실 내 알데하이드 농도 분포 특성 비교)

  • Lim, Bo-A;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.36
    • /
    • pp.49-63
    • /
    • 2015
  • In this study, the annual and seasonal concentrations of aldehydes was measured using the active type and passive type method in the temporary exhibition hall and outdoor air. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the ${\Sigma}$ aldehydes in exhibition hall by the active type was higher than 6.4 times by passive type. The formaldehyde was exceeded standards in exhibition facilities of the Ministry of Environment. It was the highest concentrations in summer. Annual I/O ratio of formaldehyde was 5.4 and acetaldehyde was 1.9, it was confirmed that a large amount occurs in the temporary exhibition hall. The results of the correlation coefficient and the t-test of formaldehyde were a strong positive linear relationship between the active type and the passive type.

  • PDF

A Study on Analysis of Body Types of Active Senior Males (aged 55-69) -Focused on the Comparison with the Middle Aged Males (aged 35-54)- (액티브 시니어 남성(55~69세) 체형 분석 -중년 남성(35~54세)과 체형 비교를 중심으로-)

  • Kim, Ji-Eun;Kim, Eun-Kyong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.722-740
    • /
    • 2017
  • This study was conducted to offer basic data that can be used in a clothing industry for active senior males that are emerging as a new consumer bracket in a rapid aging age. To this end, this study conducted an analysis of 'younger' older male body types based on data from the 6th Size Korea. As a result of the body type analysis of 'younger' older males who are considered active seniors in comparison to 'middle' aged males, the former's height items became shorter compared to 'middle' aged males, but circumference items were bigger. Males aged 35-69, who are 'middle' aged males and 'younger' old males were divided into three body types in this study: Type1- small body type with protruded belly, compared to weight. Type 2- body type of slim torso with wide shoulder-back widths. Type3- big body type overall with tall height and heavy weight. According to body type distribution by age group, the middle-aged males had Type2 body type the most. The younger-old males showed type1 the most. There is a need to reflect the body types of active senior male characteristics in apparel pattern design because the current fits are not appropriate if active senior males wear clothing targeted for males aged 30-50.

The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구)

  • Lee, Dong-Won;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

A Study on Switching Characteristics of Active Clamp Type Flyback Converter with Synchronous Rectifier Driving Signals Controlling Auxiliary Switch (보조스위치가 동기정류기 구동 신호로 제어되는 능동 클램프형 플라이백 컨버터의 스위칭 특성에 관한 연구)

  • Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, the switching characteristics of the active clamp type flyback converter, which is deemed suitable for the miniaturization of the external power supply for home appliance, were analyzed and the process of reducing the switching loss was explained. The active clamp type flyback converter operating in the DCM has confirmed that the surge voltage of the main switch does not occur and the turn-off / on loss of the switch do not occur in principle. Also, in the case of the switch for synchronous rectifier, it was showed that the switch current showed half-wave rectified sinusoidal characteristic, and the switching loss was reduced. The switching characteristics of the experimental results gathered from 120 W class prototype were compared with the theoretical waveform in the steady-state and it was confirmed that the power conversion efficiency of the active clamp type flyback converter was maintained high due to the reduction of the switching loss.

The Middle Age Women's the Image Evaluation and the Preference of Tailored Jacket According to the Body Type and the Degree of Body Satisfaction - Focused on the Collar's Figure- (중년여성의 체형과 신체만족도에 따른 테일러드 재킷의 이미지 평가 및 선호도 - 칼라형태를 중심으로 -)

  • Ryoo, Sook-Hee;Park, Jong-Hee
    • Fashion & Textile Research Journal
    • /
    • v.6 no.3
    • /
    • pp.367-376
    • /
    • 2004
  • The purpose of this study is to analyze the image evaluation and the preference of tailored jacket focused on the collar's figure according to the body type and the degree of satisfaction with their body of middle-aged women. For this study, twenty seven different types of tailored jacket were designed with some variation of their silhouette, the length and the collar's figure on three hundred and twenty three middle-aged women ranging from 35 to 50 years old. There was a significant difference in the image evaluation and the preference of tailored jacket according to the body type of middleaged women. The women of the type 1 evaluated that portrait lapel collar were the most fascinating, elegant and active, tender and they preferred that style. The women of the type 2 evaluated that breast lapel collar were the most fascinating, elegant and active, tender and they preferred that style. The women of the type 3 evaluated that breast lapel collar were the most fascinating, elegant and active, tender and they preferred that style. The women of the type 4 evaluated that waist lapel collar were the most fascinating, elegant and active, tender and they preferred that style. There was a meaningful difference in the image evaluation and the preference of tailored jacket according to the degree of satisfaction with their bodies. As satisfied with their face size, they thought breast/portrait lapel collar were more attractive, graceful and active, soft and they preferred that style. As satisfied with weight they regarded portrait lapel collar as more attrative, graceful and active, soft and they preferred that style. In this study we found that the middle-aged women evaluated the tailored jacket which was looking esthetic and fitting their body types, as the most attrative, elegant, active, and tender clothing and they prefered that kind of tailored jacket.

Approximate Design Optimization of Active Type Desk Support Frame for Float-over Installation Using Meta-model (메타모델을 이용한 플로트오버 설치 작업용 능동형 갑판지지프레임의 근사설계최적화)

  • Lee, Dong Jun;Song, Chang Yong;Lee, Kangsu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 2021
  • In this study, approximate design optimization using various meta-models was performed for the structural design of active type deck support frame. The active type deck support frame was newly developed to facilitate both transportation and installation of 20,000 ton class offshore plant topside. Structural analysis was carried out using the finite element method to evaluate the strength performance of the active type deck support frame in its initial design stage. In the structural analysis, the strength performances were evaluated for various design load conditions that were regulated in ship classification organization. The approximate optimum design problem based on meta-model was formulated such that thickness sizing variables of main structure members were determined by achieving the minimum weight of the active type deck support frame subject to the strength performance constraints. The meta-models used in the approximate design optimization were response surface method, Kriging model, and Chebyshev orthogonal polynomials. The results from approximate design optimization were compared to actual non-approximate design optimization. The Chebyshev orthogonal polynomials among the meta-models used in the approximate design optimization represented the most pertinent optimum design results for the structure design of the active type deck support frame.

Active Vibration Control Experiment of Cantilever Using Active Linear Actuator for Active Engine Mount (능동 엔진 마운트 제어용 Active Linear Actuator를 이용한 외팔보 능동진동제어 실험)

  • Yang, Dong-Ho;Kwak, Moon-K.;Kim, Jung-Hoon;Park, Woon-Hwan;Sim, Ho-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1176-1182
    • /
    • 2010
  • Vibrations caused by automobile engine are absorbed mostly by a passive-type engine mount. However, user specifications for automobile vibrations require more stringent conditions and higher standard. Hence, active-type engine mount have been developed to cope with such specifications. The active-type engine mount consists of sensor, actuator and controller where a control algorithm is implemented. The performance of the active engine mount depends on the control algorithm if the sensor and actuator satisfies the specification. The control algorithm should be able to suppress persistent vibrations caused by the engine which are related to engine revolution. In this study, three control algorithms are considered for suppressing persistent vibrations, which are the positive position feedback control algorithm, the strain-rate feedback control algorithm, and the modified higher harmonic control algorithm. Experimental results show that all the control algorithms considered in this study are effective in suppressing resonant vibrations but the modified higher harmonic controller is the most effective controller for non-resonant vibrations.