• 제목/요약/키워드: Active source

검색결과 1,446건 처리시간 0.018초

직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법 (A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator)

  • 장훈;이우철;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

전원 불평형과 역률을 보상하는 직렬형 능동전력필터의 통합적 제어 (Integrative Control of Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;석줄기;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.258-264
    • /
    • 2006
  • This paper presents an integrative control scheme for series-type active power filters combined with shunt passive filters not only to compensate for the source voltage unbalance and current harmonics but also to correct the power factor. To reduce the power capacity of the active filters, passive filters are connected in parallel. Diode rectifiers are replaced by the PWM converters in order to feed the real power back to the source. Power factor control is performed by changing the phase of the load voltage so that the phase of the source current coincides with that of the source voltage. The resultant voltage reference is the addition of the voltage component compensating for the source voltage unbalance and harmonic currents and the voltage component correcting the power factor. The validity of the proposed algorithm has been verified by experimental results.

복합음원이 적용된 능동방음벽에 관한 선행 연구 (A Preliminary Study on the Application of Compound Sources to Active Noise Barrier)

  • 백광현
    • 한국음향학회지
    • /
    • 제30권1호
    • /
    • pp.42-48
    • /
    • 2011
  • 본 연구는 능동 방음벽의 성능과 관련하여 제어 음원으로서 복합음원의 사용 가능성을 알아보았다. 복합음원은 근접거리에 위치하며 위상이 반대인 두 개의 단극음원으로 구성된다. 한 조의 복합음원 내 두 개의 단극음원의 세기는 각각 별도의 제어 채널을 구성하여 제어 되는 것이 아닌, 수음점 쪽에 위치한 음원의 세기에 다른 하나가 상수배로 비례하여 제어된다. 따라서 제어 시스템의 하드웨어 구성 비용이 낮아지며, 단극음원 하나당 한 채널로 구성되는 제어시스템에 비하여 비교적 세밀한 음장 형성이 가능하다고 알려져 있다. 본 연구에서는 이러한 복합음원을 방음벽 양쪽에 무반사 바닥면을 가지는 비교적 간단한 시스템에 적용하여 단극음원 대비 어느 정도의 효용성이 있는지 컴퓨터 시뮬레이션을 통하여 알아보았으며 30~40 % 정도의 성능 향상이 가능함을 보여주었다.

전류 고조파와 불평형 전원 전압을 보상하는 직렬형 능동전력 필터와 병렬형 수동전력필터 병용시스템의 새로운 제어법 (A Novel Control Method of Combined System consists of Series Active Power Filter and Parallel Passive Power Filter to Compensate Current Harmonics and Unbalanced Source Voltages)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.615-623
    • /
    • 2001
  • In this paper, we study a series active power filter to compensate current harmonics and unbalanced source voltages. Conventional control methods for compensating unbalanced source voltages use source voltages to calculate compensation voltages, and in addition use load voltages to regulate load voltages. But the proposed control method uses load voltage to compensate unbalanced source voltages and regulate load voltages. And we propose a control method to reduce current harmonics which can calculate compensation voltages directly from source currents and load voltages. By well-matched operation of two control methods, the series active power filter can compensate current harmonics, unbalanced source voltages, and regulate load voltages. We compose a combined system of the series active power filter and parallel passive filters to confirm a validity of proposed control methods. The results from experiments are presented to demonstrate effectiveness of the proposed method.

  • PDF

직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상 (The Compensating Unbalanced Source Voltages for Unified Active Power Filter System)

  • 김영석;강민형
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.

회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기 (A New Controller of Single Phase Active Power Filter Using Rotating Synchronous Frame d-q Transformation)

  • 강민구
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.271-275
    • /
    • 2014
  • 회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기를 제안하였다. 힐버트 변환기를 사용하여 $90{\circ}$의 위상차를 가지는 두 개의 교류 신호를 만든다. 이 신호들을 회전하는 동기 좌표계 d-q 변환을 이용하여 기본파 성분을 직류로 변환할 수 있고 따라서 고조파 검출이 용이하다. 순시 유효 전력의 평균값을 구한다. 역률 보상을 하므로 전원 전류는 전원 전압과 동위상이다. 단상에서의 전력 공식으로부터 전원 전류의 크기를 알 수 있다. 능동 전력 필터의 보상 전류의 기준 신호는 전원 전류의 기준신호에서 부하 전류를 빼주면 구할 수 있다. 새롭게 제안된 제어기에 히스테리시스 전류 제어기를 적용하여 시뮬레이션 하였다. 능동 전력 필터가 부하전류의 고조파와 무효전력을 보상하여 전원 전류가 전원전압과 동위상이 되고 전원전류가 정현파에 가깝게 되는 것을 확인하였다. 힐버트 변환기는 전대역 여파기를 사용하여 구현하였다.

이동 애드혹 네트워크에서 신뢰성 향상을 위한 액티브 기반연구 (The Study Active-based for Improvement of Reliablity In Mobile Ad-hoc Network)

  • 박경배;강경인;유재휘;김진용
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.188-198
    • /
    • 2002
  • 본 논문에서는 이동 애드혹 네트워크에서 신뢰성 향상을 위한 액티브 네트워크를 제안하였다. 제안된 알고리즘에서는 DSR을 기본 프로토콜로서 액티브네트워크를 구성하였고, 송수신 노드를 액티브 노드로서 이용하였다. 신뢰성 향상을 위해 송신노드는 최근 보낸 데이터를 저장할 임시 버퍼를 생성한 후 수신노드의 요구에 의해 데이터 재전송을 수행하며 수신노드 당 흐름관리를 할 수 있는 기능을 추가하여 송신 액티브노드로 기능을 변경하였다. 수신노드는 손실된 데이터에 대한 재 전송요구와 흐름제어 기능을 추가하는 수신 액티브노드로 기능을 변경하였다. 그 결과로서, 제안된 액티브 노드는 움직임이 적은 이동 애드혹 네트워크에서는 100[%]에 근접하는 신뢰성을 보였고, 움직임이 많은 이동 애드혹 네트워크에서 보다 평균 3.5737% 증가한 95%의 데이터 수신율을 보장하였다.

  • PDF

3상 Z-소스 하이브리드 능동전력필터 시스템 (Three-Phase Z-Source Hybrid Active Power Filter System)

  • 임영철;김재현;정영국
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.75-85
    • /
    • 2010
  • 본 연구에서는 비선형 부하에서 발생되는 기본파 무효전력 및 고조파를 보상하기 위한 종전의 전압형 및 전류형 PWM 능동전력필터를 대체 할 수 있는 Z-소스 인버터 토폴로지의 하이브리드 능동전력필터에 대하여 고찰하였다. Z-소스 토폴로지의 능동전력필터의 보상 DC전원으로는 PEMFC가 사용되며, Z-소스 인버터의 shoot-through 듀티비의 조절에 의하여 낮은 연료전지의 전압을 높은 보상 전압으로 부스트 한다. 제안된 시스템은 병렬형 Z-소스 능동전력필터와 7차 고조파 (420Hz) 동조 필터로 구성되며, 이 구성에 의하여 Z-소스 능동전력필터의 스위치 디바이스의 전압 스트레스는 감소된다. 제안된 Z-소스 하이브리드 능동전력필터의 보상 알고리즘으로는 전류 동기 검출법이 사용되었다. 3상 220V/60Hz, 25A급 비선형 다이오드 부하 조건하에서 PSIM 시뮬레이션을 수행하였으며, 정상상태 및 과도상태에서의 제안된 시스템의 보상 성능을 파악하였다.

무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터 (A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power)

  • 이우철;현동석;이택기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF

연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감 (Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source)

  • 정영국
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.