• Title/Summary/Keyword: Active power loss

Search Result 271, Processing Time 0.022 seconds

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Implementation of an Interleaved AC/DC Converter with a High Power Factor

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.377-386
    • /
    • 2012
  • An interleaved bridgeless buck-boost AC/DC converter is presented in this paper to achieve the characteristics of low conduction loss, a high power factor and low harmonic and ripple currents. There are only two power semiconductors in the line current path instead of the three power semiconductors in a conventional boost AC/DC converter. A buck-boost converter operated in the boundary conduction mode (BCM) is adopted to control the active switches to achieve the following characteristics: no diode reverse recovery problem, zero current switching (ZCS) turn-off of the rectifier diodes, ZCS turn-on of the power switches, and a low DC bus voltage to reduce the voltage stress of the MOSFETs in the second DC/DC converter. Interleaved pulse-width modulation (PWM) is used to control the switches such that the input and output ripple currents are reduced such that the output capacitance can be reduced. The voltage doubler topology is adopted to double the output voltage in order to extend the useable energy of the capacitor when the line voltage is off. The circuit configuration, principle operation, system analysis, and a design example are discussed and presented in detail. Finally, experiments on a 500W prototype are provided to demonstrate the performance of the proposed converter.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Phase-shedding in Boundary Conduction Mode Converter with Optimal Transition Load-level

  • Choi, Wooin;Baek, Jong-Bok;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.73-74
    • /
    • 2011
  • Phase-shedding, one famous technology for multi-phase converters, is implemented in a bi-directional multi-phase converter for ESS. It reduces active operating modules at light load to compensate efficiency. Shedding point, the load level where the converter changes the number of active modules, is important factor that affects the effect of phase-shedding. Loss analysis is done for determining shedding point. Phase-shedding hysteresis is applied so that excessive phase transition is avoided. This paper proposes shedding point correction where the shedding point is adaptively corrected by calculating a new shedding point.

  • PDF

An Experimental Study on Internal and External Negotiation for Trade Agreements

  • Sung, Hankyoung
    • East Asian Economic Review
    • /
    • v.21 no.2
    • /
    • pp.103-121
    • /
    • 2017
  • This paper experimentally studies the performance of negotiation considering individual and party, like a country, share of benefit over the best ones. It experiments two-stage bargaining games, internal and external negotiations. From the experimental results, this paper shows strong tendency to select fair allocation in the internal negotiations, but the tendency would be weaker with attractive outside option. In addition, the outside option may claim difference in individual benefit. From the regressions on individual performance in the negotiations, being a proposing party would matter to enhance the performance. However, relative individual performance within party fairness matters. Still attractive no-agreement options happen to break the tendency. As policy implication for trade negotiation, this paper warns that possible loss in individual benefit from not active participation to the external negotiations, no active role of proposer in case that players stick to internal allocations, and deviation of advantageous sector due to attractive outside options.

A ZVS Resonant Converter with Balanced Flying Capacitors

  • Lin, Bor-Ren;Chen, Zih-Yong
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1190-1199
    • /
    • 2015
  • This paper presents a new resonant converter to achieve the soft switching of power devices. Two full-bridge converters are connected in series to clamp the voltage stress of power switches at Vin/2. Thus, power MOSFETs with a 500V voltage rating can be used for 800V input voltage applications. Two flying capacitors are connected on the AC side of the two full-bridge converters to automatically balance the two split input capacitor voltages in every switching cycle. Two resonant tanks are used in the proposed converter to share the load current and to reduce the current stress of the passive and active components. If the switching frequency is less than the series resonant frequency of the resonant tanks, the power MOSFETs can be turned on under zero voltage switching, and the rectifier diodes can be turned off under zero current switching. The switching losses on the power MOSFETs are reduced and the reverse recovery loss is improved. Experiments with a 1.5kW prototype are provided to demonstrate the performance of the proposed converter.

Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation (EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안)

  • Sung, Ung;Kim, Jae-Won;Kim, Tae-Gyun;Lee, Byong-Jun;Jung, Eung-Soo;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

The Experimental Consideration about Loss of Three-phase Voltage-fed inverter Resonant DC Link (ARDCL를 이용한 3상 전압형 인버터의 해석과 고성능화의 고찰)

  • Jun, C.W.;Kim, S.I.;Mun, S.P.;Kim, H.J.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.166-170
    • /
    • 2003
  • This paper deals with the power loss analysis of voltage source type space voltage vector modulated soft switching inverter, and proposed the new voltage vector correction principle during one sampling period on realize high quality cutput voltage waveforms for two soft-swiching approches. The operating pinciple of a single active auxiliary resonant DC link snubber circuit is described. Moreover, the effectiveness of soft switching inverter operating under the corrected voltage pattern is proved on the basis of simulation and experimental results.

  • PDF

Novel Multiple Output Converter using Quasi Load

  • Choi, Kyu-Sik;Hyun, Byeong-Chul;Lee, Seoung-Woon;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.125-126
    • /
    • 2010
  • In this paper, a novel multiple output converter using quasi load is proposed. Conventional multiple output converters using multi-winding transformer has poor output voltage regulations. To solve this problem, there are many proposals like post regulation method, weighted control method, and etc. However, the post regulation method regulates output voltage tightly but its conduction loss and cost are increased. And the weighted control can achieve high efficiency and low cost but its regulation is not enough. To solve these problems, this paper proposes a novel multiple output converter using quasi load. The proposed method uses a quasi load which acts like an active dummy load for tight regulation but there is rarely increase of loss and cost. The proposed method is verified by hardware test by two output(24V and 15V) flyback type converter.

  • PDF