• 제목/요약/키워드: Active power loss

검색결과 269건 처리시간 0.032초

전렬계통의 합리적 운용제어에 관한 연구 (A Study on the Optimum Operational Control of Power System)

  • 정재길;박영문
    • 대한전기학회논문지
    • /
    • 제33권10호
    • /
    • pp.410-422
    • /
    • 1984
  • This paper presents a new practical method for optimal active and reactive power control for the economic operation in electrical power system, and the programs are developed for digital computer solution. The major features and techniques of this paper are as follows: 1) The method is presented for finding the equivalent active power balance equation applying the sparse Jacobian matrix of power flow equation instead of using B constant as active power balance equation considering transmission loss, and thus for determining directly optimal active power allocation berween generator unitw satisfying the equality and inequality constraints. 2) The method is proposed for solving directly the optimum economim dispatch problem without using gradient method and penalty function for both active and reactive power control. As a result, the computing time are reduced and convergence characteristic is remarkably improved. 3) Unlike most of conventional methods which adopt the transmission loss as a objective function for reactive power control, the total fuel cost of themal power plant is adopted as objective function for both active and reactive power control. consequently, more reasonable and economic profit can be achieved.

DAB 컨버터용 전력 변압기의 누설 인덕턴스를 포함한 내부 전력 손실 분석에 관한 연구 (A Study on the Analysis of Internal Power Loss Including Leakage Inductance of Power Transformer for DAB Converter)

  • 유정상;안태영;길용만
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.95-100
    • /
    • 2022
  • In this paper, a power loss analysis technique of a high-frequency transformer of a bidirectional DAB (Dual Active Bridge) converter is reported. To miniaturize the transformer of the dual active bridge converter, a resonant inductor was designed with an air gap included low-coupled rate state core to combine leakage inductor with the resonant inductor which is required for soft-switching. In this paper, leakage inductance and magnetizing inductance, core material, type of winding and winding method are included in the dual active bridge transformer loss analysis process to enable optimal design at the initial design stage. Transformer loss analysis for dual active bridge with a switching frequency of 200 kHz and maximum output of 5 kW was executed, and elements necessary for design based on the number of turns on the primary side were graphed while maintaining the transformer turns ratio and window area. In particular, it was possible to determine the optimal number of turns and thickness of the transformer, and ultimately, the total loss of the transformer could be estimated.

유무효전력설비의 적소투입을 통한 전력손실개선 (System Loss Improvement through Proper Location of Active and Reactive Power Apparatus)

  • 이상중
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.77-80
    • /
    • 2000
  • 본 논문은 有無效 섣둡jJ設觸의 投貴위치와 그 용향을 적정화하여 동일한 설비투자량에 대하여 전력손실을 최소화하는 방안에 대하여 설명하였다. 유효 및 무효전릭의 미소증분에 대한 손실의 변화를 나타내는 모선의 손실감도를 소개하고 전력송실을 최대한 개선하기 워한 유무효전력 설비의 투자지표로 이용하였다. 각 모선에 주어지는 투자지표의 우선순위에 따라 유효 및 무효전력설비가 투자되어 전력손실을 최소화한다.

  • PDF

무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계 (Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권1호
    • /
    • pp.30-36
    • /
    • 1993
  • 본 연구는 정류기의 입력전류에 포함되어 있는 고조파성분을 제거하고 입력역률을 개선하기 위해 무손실 저항(Loss Free Resistor) 개념에 기본을 둔, PC, 가전기기 및 형광등용 전자안정기등과 같은 저전력 전원설비에 적합한 불연속 도통모드(DCM) 플라이백 방식의 능동역률 보정기의 등가회로모델 및 설계법을 제시하였다. 이 개념에 의하여 능동역률 보정기의 등가입력저항, 출력전력원 특성을 정확하게 나타낼 수 있었으며 또 설계방정식을 유도하여 능동역률 보정기를 설계 시험한 결과, 적은 부품으로 정류기의 입력교류 전류에 포함되어 있는 고주파를 제거하였고 따라서 0.98의 고입력역률의 정류를 할 수 있었다.

  • PDF

배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상 (Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line)

  • 이상훈;김수빈;송승호
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

보조스위치가 동기정류기 구동 신호로 제어되는 능동 클램프형 플라이백 컨버터의 스위칭 특성에 관한 연구 (A Study on Switching Characteristics of Active Clamp Type Flyback Converter with Synchronous Rectifier Driving Signals Controlling Auxiliary Switch)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, the switching characteristics of the active clamp type flyback converter, which is deemed suitable for the miniaturization of the external power supply for home appliance, were analyzed and the process of reducing the switching loss was explained. The active clamp type flyback converter operating in the DCM has confirmed that the surge voltage of the main switch does not occur and the turn-off / on loss of the switch do not occur in principle. Also, in the case of the switch for synchronous rectifier, it was showed that the switch current showed half-wave rectified sinusoidal characteristic, and the switching loss was reduced. The switching characteristics of the experimental results gathered from 120 W class prototype were compared with the theoretical waveform in the steady-state and it was confirmed that the power conversion efficiency of the active clamp type flyback converter was maintained high due to the reduction of the switching loss.

Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법 (A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter)

  • 이준영;최현준;김주용;정지훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

전류원형 능동 전력 필터의 직류측 모델에 관한 연구 (A Study on DC side Model of Current Source type Active Power Filters)

  • 한학근;박인규;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.180-185
    • /
    • 1989
  • In the current source type active power filter, the DC current source is implemented using an inductor with large inductance by maintaining the inductor current constantly. In this case, to compensate the loss of the switching devices of the power converter and the inductor, some real power should be supplied to the filter from the source. This process is analyzed through the equivalent circuit which expresses the loss of the switching devices and the inductor with the equivalent resistor R. This work discusses the validation of this DC side equivalent circuit and points out the problems, through the experiments using the experimental active power filter with 220V, 10KVA ratings, and suggests a more accurate equivalent circuit which puts the saturation voltage of the power transistors and the threshold voltage of the diodes into consideration.

  • PDF

능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선 (Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode)

  • 윤신용;백수현;김용;김철진;어창진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Active NPC 인버터를 적용한 계통연계 전력변환 시스템의 제어 (Control of Grid-Connected Power Conversion Systems using an Active NPC Inverter)

  • 김성원;서동우;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.155-156
    • /
    • 2018
  • This paper presents a control method for grid-connected Active-NPC inverter systems. NPC (Neutral Point Clamped) is widely used in power conversion systems. NPC has a loss of switching elements and voltage imbalance. Active NPC has been proposed to overcome these drawbacks. ANPC changed the neutral diode to IGBT to reduce the switching loss. This paper modeled a grid-connected Acitve-NPC inverter systems and analyzed its performance. DSOGI PLL was used as a phase control method for precise control of grid link voltage. The proposed method is verified by PSIM simulation.

  • PDF