• Title/Summary/Keyword: Active noise reduction

Search Result 225, Processing Time 0.027 seconds

Active Noise Control of the Plane Wave Travelling in a Duct Using Filtered-x LMS Algorithm (Filtered-x LMS 알고리즘을 응용한 덕트내 평면파 소음의 능동제어)

  • 우재학;김인수;이정권;김광준
    • Journal of KSNVE
    • /
    • v.2 no.2
    • /
    • pp.107-116
    • /
    • 1992
  • An adaptive signal processing technique is implemented for the active noise cancellation of the plane acoustic wave propagating in a duct. To avoid the instability caused by the acoustic feedback from the control speaker to the detect microphone, an off-line modeling of the acoustic feedback plant is done using the FIR filter. Auxiliary path required for the filtered-x LMS algorithm is modeled as well. Before going into the experiments, a simulation is carried out under the same conditions with experiments. The simulation shows that the longer the length of the adaptive filter is, the better the results are achieved. Experiments have been carried out at lower audio frequency range (50 - 400Hz), and the results are in good agreements with those of simulation study. As a results of this adaptive noise control, around 50dB is reduced for a pure tone noise, and for a bandlimited noise with the bandwidth of 316Hz, a maximum of 30dB noise reduction is attained.

  • PDF

A Study on the Noise Reduction of a Portable Fuel Cell System (휴대용 연료전지 시스템의 소음 저감에 대한 연구)

  • Jeon, In-Youl;Bae, Joon-Soo;Oh, Min-Jung;Choi, Sang-Hyeon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF

Active Window system based on Finite Thickness Window Model (유한 두께 창문 모델을 적용한 능동 소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

The Study of the Multi-Channel Active Noise Reduction of the Vehicle Cabin I : Computer Simulation (자동차 실내 소음저감을 위한 다채널 능동 소음제어에 관한 연구I : 컴퓨터 시뮬레이션)

  • Lee, T. Y.;Shin, J.;Kim, H. S.;Oh, J. E.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.95-106
    • /
    • 1992
  • Active control of acoustic noise is an application area of adaptive digital signal processing with increasingly interest along the last year. This work studies the implementation of the multichannel LMS filter and the application of this algorithm for the reduction of the noise inside a vechicle cabin using a number of 'secondary sources' drived by adaptive filtering of a reference noise source. Firstly, we propose the use of an adaptive method for the time-varient optimal convergence factor. Secondly, we propose the use of adaptive delayed inverse model to estimate the elastic-acoustic transfer function presented in vechicle cabin. The original, primary source is often periodic, with a known fundamental frequency. A suitably filtered reference signal can thus be used to drive the secondary sources. An algorithm is presented for adapting the coefficients of an FIR filter feeding such a secondary source in such a way as to minimize the output of a suitably placed microphone. In this algorithm, the coefficients of adaptive filter driving an array of secondary sources can be adapted to minimize the sum of the squares of the outputs of a number of error microphones. The multichannel LMS algorithm displays that such an algorithm is considered suitable to used for the global suppression of noise in vehicle cabin.

  • PDF

Active vibration control of a flexible cantilever beam using Filtered-x LMS algorithm (Filtered-x LMS 알고리즘을 이용한 유연한 외팔보의 능동진동제어)

  • 박수홍;홍진석;김흥섭;오재응
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.107-113
    • /
    • 1997
  • This paper presents the active control of a flexible cantilever beam vibration. The cantilever beam was excitied by a steady-state harmonic and white noise point force and the control was performed by one piezo ceramic actuator bonded to the surface of the beam. An adaptive controller based on filtered-x LMS algorithm was used and the controller was defined by minimizing the square of the response of error sensor. In the experiment, gap sensor was used as an error sensor while the sinusoidal or white noise was applied as a disturbance. In the case of sinusoidal input, more than 20 dB of vibration reduction was achieved over all range of the natural frequencies and it takes 5 seconds to control the vibration at first natural frequency and 1 second at other natural frequencies. In the case of white noise input, 7 dB of vibration reduction was achieved at the first natural frequency and good control performance was achieved in the considered whole frequency range. Results indicate that the vibration of a flexible cantilever beam could be controlled effectively when the piezo ceramic actuator was used with filtered-x LMS algorithm.

  • PDF

DSP Implementation of Hysteresis Control for Active Noise Control (능동소음제어를 위한 히스테리시스 제어의 DSP 구현)

  • 이승요;성덕만;최규하;강정유;황희융;장도현
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.93-98
    • /
    • 1996
  • This paper presents active silencer by hysteresis control method using DSP-scheme and shows it audible noise reduction effect. Pentium processor and sound blaster 16 are used for its implementation. The sound blaster 16 executes A/D, D/A conversion and is used operating source of loudspeaker for cancelling.

  • PDF

Structure Vibration Analysis and Active Noise Control of Power Transformer (전력용변압기의 구조진동해석 및 능동소음제어)

  • Jeong, Yun-Mi;Choi, Eun-Ji;Kim, Young-Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1771-1776
    • /
    • 2013
  • Most cases of power transformer failure are caused by physical factors linked to the transient vibrations of multiple 120Hz combinations. In addition, the noise generated in the transformer from this vibration not only directly contributes to the worsening of the work environment but also causes psychological stress, resulting in the worsening of the workers efficiency and of the living environment of the inhabitants around the power plant. Thus, to remedy these problems, the mechanical-excitation forces working on a power transformer were categorized in this study, and the mechanical-damage mechanism was identified through the vibration transfer paths acting on machines or structures. In addition, a study on active noise cancellation in a transformer using the FXLMS algorithm was conducted to develop a system that is capable of multiple-sound/channel control, which resulted in the active noise reduction effect when applied on the field.

A Design of the Robust Controller for an Active Noise Control

  • Chung, Tae-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1E
    • /
    • pp.3-9
    • /
    • 1998
  • In this paper, a robust active noise controller is designed to reduce noise in al small cavity. Noise characteristics in the small cavity are nonlinear and we could get its model with considerable modelling errors. The objective of this paper is to minimize the effects of these modelling errors and maximize the noise reduction performance. The solution could be obtained by the H∞ robust control theory. The resulting feedback controller minimizes the H∞ norm of the mixed sensitivity function, which means the effects of uncertainties of the model are suppressed in the sense of stability and the performance is enhanced as a given specification. The designed controller is realized with analog devices such as Op. Amps and experimental results show that the controller reduces noise signal sufficiently.

  • PDF

Design optimization and vibratory loads analysis of active twist rotor blades incorporating single crystal piezoelectric fiber composites (단결정 압전섬유작동기를 사용한 능동 비틀림 로터 블레이드의 최적 설계 및 진동하중 해석)

  • Park, Jae-Sang;Shin, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.85-92
    • /
    • 2007
  • This paper presents a design optimization of a new Advanced Active Blade Twist (AATR-II) blade incorporating single crystal Macro Fiber Composites (MFC) and conducts vibratory loads reduction analysis using an obtained optimal blade configuration. Due to the high actuation performance of the single crystal MFC, the AATR blade may reduce the helicopter vibration more efficiently even with a lower input-voltage as compared with the previous ATR blades. The design optimization provides the optimal cross-sectional configuration to maximize the tip twist actuation when a certain input-voltage is given. In order to maintain the properties of the original ATR blade, various constraints and bounds are considered for the design variables selected. After the design optimization is completed successfully, vibratory load reduction analysis of the optimized AATR-II blade in forward flight condition is conducted. The numerical result shows that the hub vibratory loads are reduced significantly although 20% input-voltage of the original ATR blade is used.

  • PDF