• Title/Summary/Keyword: Active loudspeaker system

Search Result 12, Processing Time 0.024 seconds

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

Optimal Loudspeaker Positions of an Active Noise Control System with an Opening in an Enclosure (개구부를 가지는 실내의 능동소음제어시스템에서의 최적스피커 위치)

  • 백광현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.788-791
    • /
    • 2003
  • Optimal loudspeaker positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in the enclosure. An optimization technique called simulated annealing algorithm is used to find a set of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wail. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions we identified and compared. When a small number of loudspeakers are used, loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns Un the optimal positions.

  • PDF

TWO TYPES OF ACTIVE NOISE CONTROL SYSTEM USING MFB LOUDSPEAKER

  • Nishimura, Yoshitaka;Shimada, Yasuyuki;Usagawa, Tsuyoshi;Ebata, Masanao
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.764-769
    • /
    • 1994
  • The impedance of an electro-acoustic transducer can be controlled by motional feedback, and the noise in a duct can be reduced actively by adjusting the impedance using an additional sound. In this paper, two approaches for active noise control using motional feedback (MFB) loudspeaker are described. First configuration uses an external sensor to pickup of source directly. In this configuration, the adaptation of controller is necessary to compensate the change of transfer function from noise source to control poing. The second configuration uses a new adaptive algorithm specialized for peridic noise. Because this configuration does not require any reference input and the error sensor couples very tightly with control loudspeaker, this MFB system itself is independent of the duct condition. No microphone are required in both configurations, so that a more reliable and stable active control system can be realized under severe conditions such as high pressure, high temperature, dust, flow and so on.

  • PDF

Optimal Transducer Positions of an Active Noise Control System with an Opening in an Enclosure (개구부를 가지는 실내의 능동소음제어시스템의 최적 트랜스듀서 위치)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Optimal transducer positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in an enclosure. Optimization techniques are used to find sets of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wall and inside of the enclosure. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions are identified and compared. When a small number of loudspeakers are used. loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns in the optimal positions. With the optimally positioned loudspeakers, optimal microphone positions are also studied.

Active Noise Control Barrier for Acoustic Hardware System Design (능동형 방음벽 개발을 위한 H/W 시스템 설계)

  • Cha, Sang-Gon;Troshin, Andrey G.;Kim, Dong-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2368-2373
    • /
    • 2011
  • Traffic noise annoyance in dwelling area like private houses and apartment is becoming very important issue nowadays in South Korea. In this paper frequency analysis of the traffic noise was performed. Based on sound pressure levels analyses and its frequency content specific requirements for component of active noise control systems are formulated. Active compensational loudspeaker, microphone front end and DSP design were analysed, considered and proposed. Components specifications and design solutions are verified using modelling and experimental technique.

The Performance Comparison of Active Noise Controller With Phase Difference (위상차에 따른 소음 제거기의 성능 비교)

  • 최창권;조병모
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.695-698
    • /
    • 1999
  • Passive noise reduction is a classical approach to attenuate industrial noise. But Active noise cancellation has several advantages over the passive noise cancellation. Such a system offers a better low frequency performance with a smaller and lighter system. This paper presents an active closed loop control system which consists of an controller for inverting and compensating the phase delay, an microphone for picking up the external noise, and loudspeaker for radiating the acoustic anti-phase signal to reduce external noise. The noise in the phase delay covered from 80$^{\circ}$ to 270$^{\circ}$ tends to be reduced. The degree of noise cancellation obtainable with this system reaches value about 17㏈.

  • PDF

Active Control for Outdoor Noise using an FXLMS Approach

  • Hou, Hai-Feng;Kim, Dong-Il;Lee, Young-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.672-672
    • /
    • 2011
  • This study describes the comparison of noise suppression performances at different locations of two error microphones in active noise control (ANC) for outdoor applications. For this study, 12 different locations were predefined to decide best locations for error sensors in terms of suppressing noise. As shown in Fig. 1, the ANC system with one primary loudspeaker, two secondary loudspeakers and two error microphones is operated by a filtered-x LMS (FXLMS) algorithm which is implemented in a TI 6713 DSP board and Realsys 4713 AD/DA Extension board. The noise for the primary source is a typical road noise measured at a highway roadside. The lengths of adaptive filters of W1 and W2 are varied from 32 to 128 respectively. An intensive computer simulation was accomplished before outdoor ANC experiments. It is expected from the simulation results that the ANC performances are very much dependent upon the locations of the two error microphones.

  • PDF

Noise Reduction using Passive and Active Noise Control in the Closed Area (수동과 능동방식을 혼용한 폐공간에서 소음감쇠)

  • Cho Byung-Mo
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.16-23
    • /
    • 2001
  • Passive noise reduction is a classical approach to attenuate industrial noise, and an active noise cancellation has several advantages over the passive noise cancellation. The active noise reduction system offers a better low frequency performance with a smaller and lighter system. This paper presents a simple active closed loop control system which consists of an controller for inverting and compensating the phase delay, a microphone for picking up the external noise, and a loudspeaker for radiating the acoustic out of phase signal to reduce the external noise, and external noise can be reduced after compensating the phase difference to be $180^{\circ}$ in the frequency of maximum value in the amplitude response. The noise of the phase delay covered from $50^{\circ}\;to\;310^{\circ}$ tends to be reduced in the active noise control system and it is possible to obtain a noise cancelling of up to approximately 20[dB] at the ears in the enclosurer.

  • PDF

Design of piezoelectric transducer arrays for passive and active modal control of thin plates

  • Zenz, Georg;Berger, Wolfgang;Gerstmayr, Johannes;Nader, Manfred;Krommer, Michael
    • Smart Structures and Systems
    • /
    • v.12 no.5
    • /
    • pp.547-577
    • /
    • 2013
  • To suppress vibration and noise of mechanical structures piezoelectric ceramics play an increasing role as effective, simple and light-weighted damping devices as they are suitable for sensing and actuating. Out of the various piezoelectric damping methods this paper compares mode based active control strategies to passive shunt damping for thin plates. Therefore, a new approach for the optimal placement of the piezoelectric sensors/actuators, or more general transducers, is proposed after intense theoretical investigations based on the Kirchhoff kinematical hypotheses of plates; in particular, modal and nilpotent transducers are discussed in detail. Based on the proposed distribution a discrete design for modal transducers is implemented, tested and verified on an experimental setup. For active control the modal sensors clearly identify the eigenmodes, whereas the modal actuators impose distributed eigenstrains in order to reduce the transverse plate vibrations. In contrast to the modal control, passive shunt damping works without requiring additional actuators or auxiliary power and can therefore act as an autonomous system, but it is less effective compensating the flexible vibrations. Exemplarily, an acryl glass plate disturbed by an arbitrary force initialized by a loudspeaker is investigated. Comparing the different methods their specific advantages are highlighted and a significant broadband reduction of the vibrations of up to -20dB is obtained.

A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control (능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델)

  • Kwon, Ki-Ryong;Park, Nam-Chun;Lee, Kuhn-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.28-36
    • /
    • 1995
  • In this paper, a double loop control model using leaky delay LMS algorithm are proposed for active noise control. The proposed double loop control model estimates the loudspeaker characteristic and the error path transfer function with on-line using only gain and acoustic time delay to reduce computation burden. The control of error signal through double loop control scheme makes the more robust cntrol system. The input signal of filter to estimate acoustic time delay is used difference between input signal of input microphone and adaptive filter output. And also, in nonstationary environments, the leaky delay LMS algorithm is employed to counteract parameter drift of delay LMS algorithm. For practical noise signal, the proposed double loop control model reduces noise level about 12.9 dB.

  • PDF