• 제목/요약/키워드: Active length

검색결과 835건 처리시간 0.028초

체형과 신체만족도에 따른 테일러드 재킷의 이미지 평가 및 선호도 - 재킷길이를 중심으로 - (The Image Evaluation and the Preference of Tailored Jacket According to the Body Type and the Degree of Satisfaction with the Body - Focused on the Length of Jacket -)

  • 류숙희;박종희
    • 한국의류산업학회지
    • /
    • 제7권2호
    • /
    • pp.211-217
    • /
    • 2005
  • The purpose of this study is to analyze the image evaluation and the preference of tailored jacket focused on the variation of the length according to the body type and the degree of satisfaction with the body of middle-aged women. For this study, twenty seven different types of tailored jacket were designed with some variation of their silhouette, the length and the collar's figure on three hundred and twenty three middle-aged women ranging from 35 to 50 years old. There was a significant difference in the image evaluation and the preference of tailored jacket according to the body type of middle-aged women. The women of the body type I evaluated that tailored jackets of the long length were more attractive, graceful, and active, soft and preferred the style, and the women of the body type II and III, them of the middle length. The women of the body type I evaluated that tailored jackets of the short length were more attractive, graceful, active, soft and preferred the style. Also there was a meaningful difference in the image evaluation and the preference of tailored jacket according to the degree of satisfaction with their bodies. As satisfied with their face size, they thought tailored jackets of the long length were more attractive, graceful and active, soft and they preferred the style. As satisfied with the girth of the hip, they evaluated the short/long tailored jackets were more attractive, graceful and active, soft and they preferred the style. As satisfied with their height they valued the long tailored jacket was more attractive, graceful and active, soft and they preferred the style.

Design of a Plasmonic Switch Using Ultrathin Chalcogenide Phase-change Material

  • Lee, Seung-Yeol
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.239-246
    • /
    • 2017
  • A compact plasmonic switching scheme, based on the phase change of a thin-film chalcogenide material ($Ge_2Sb_2Te_5$), is proposed and numerically investigated at optical-communication wavelengths. Surface plasmon polariton modal analysis is conducted for various thicknesses of dielectric and phase-change material layers, and the optimized condition is induced by finding the region of interest that shows a high extinction ratio of surface plasmon polariton modes before and after the phase transition. Full electromagnetic simulations show that multiple reflections inside the active region may conditionally increase the overall efficiency of the on/off ratio at a specific length of the active region. However, it is shown that the optimized geometrical condition, which shows generally large on/off ratio for any length of active region, can be distinguished by observing the multiple-reflection characteristic inside the active region. The proposed scheme shows an on/off switching ratio greater than 30 dB for a length of a few micrometers, which can be potentially applied to integrated active plasmonic systems.

상지 능동 진동운동이 중년여성의 신체능력 및 혈관운동성에 미치는 영향 (Effect of Active Vibro-Swing Exercise of Upper Limb on Physical Capacity and Vasomotor for Middle Aged Women)

  • 이현주;임현승;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권6호
    • /
    • pp.264-271
    • /
    • 2020
  • The purpose of this study was to investigate the effects of active vibration exercise of upper limb on physical capacity index (endurance, grip strength, balance, and flexibility) and vasomotor index (capillary length and body surface temperature) in middle aged women. 20 participants randomly divided into two groups: vibro-swing exercise (VSE) and non vibro-swing exercise (NVSE). Subjects in each group measured the 30 second arm curl test, hand dynamometer, one leg standing test, back scratch test, nail fold capillary microscope (NFM), and digital infrared thermal imaging (DITI) before and after exercise. The results showed that active vibration exercise of upper limb with vibro-swing equipment increased the endurance, balance ability, and the capillary length. In addition, changes in body temperature immediately after exercise were predicted to affect vasomotor. Active vibration exercise of upper limb has the advantage of being able to exercise anywhere regardless of the location by inducing different frequency changes in movement of various ranges and velocity. For this reason, the combination of vibration and active movement can be expected the physiological effects when producing exercise programs for middle aged women.

GSFM 펄스의 상관도에 기반한 연속 송수신 소나의 신호처리 구간 설정 방법 (A method for setting coherent processing interval of continuous active sonar based on correlation of GSFM pulse)

  • 김현수;김현우;이원오;박송화;이정훈;박규태
    • 한국음향학회지
    • /
    • 제40권5호
    • /
    • pp.401-407
    • /
    • 2021
  • 연속 송수신 소나 기술은 표적 탐지 시간간격이 짧아 표적을 탐지하고 추적하는 데 효과적인 기술이다. 연속 송수신 소나 시스템에 적합한 Generalized Sinusoidal Frequency Modulation(GSFM)펄스는 펄스 간 직교성을 유지하면서 높은 시간-주파수 곱을 얻을 수 있는 것으로 알려져 있다. 그러나 가속도를 갖는 표적이 존재할 경우 수신된 GSFM 펄스를 상관처리하는 적정한 시간 길이를 산출하는 방법에 대해서는 알려진 바가 없다. 본 논문에서는 GSFM 펄스를 사용하는 연속 송수신 소나 시스템에서 수신신호를 정합처리할 때 적합한 시간 길이를 상관도에 근거하여 산출하는 방법을 제안한다. 제안된 방법은 표적의 가속도에 따른 상관도를 계산하고 상관도에 따른 신호처리 길이를 산출한다. 부엽의 준위를 통해 제안된 방법으로 산출된 신호처리 길이를 적용할 경우 안정적인 탐지 성능을 얻을 수 있음을 보인다.

A-TIG 용접에서 용입 형상비에 미치는 아크길이와 실드가스의 영향 (The Eeffect of Arc Length and Shield Gas on Penetration Aspect Ratio in A-TIG Welding)

  • 박인기;함효식;조상명
    • Journal of Welding and Joining
    • /
    • 제26권6호
    • /
    • pp.42-47
    • /
    • 2008
  • TIG welding enables to produce high quality weldment. However it has some problems such as shallow penetration and large distortion due to low penetration aspect ratio after welding. In order to overcome those problems, there are many ongoing studies on A-TIG welding, which use active flux. In this study, the effect of arc length and shield gas on penetration aspect ratio with melt-run welding on STS 304 6t, on which active flux was spreaded, was investigated. Arc length was changed from 1mm to 3mm, and aspect ratio became higher as arc length was decreased in this range. 100% Ar gas, Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were used as shield gas in this study. When Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were applied, penetration and melting efficiency were both increased as compared with 100% Ar gas. Aspect ratio was the highest with Ar-2.5% $H_2$ mixed gas.

Study of MOSFET Subthreshold Hump Characteristics by Phosphorous Auto-doping

  • 이준기;김효중;김광수;최병덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.319-319
    • /
    • 2012
  • 현재 폭넓게 이용되고 있는 STI (Shallow Trench Isolation) 공정에서 active edge 부분에 발생하는 기생 transistor의 subthreshold hump 특성을 제어하는 연구가 활발히 이루어지고 있다. 일반적으로 STI 공정을 이용하는 MOSFET에서 active edge 부분의 얇게 형성된 gate oxide, sharp한 active edge 형성, STI gap-fill 공정 중에 생기는 channel dopant out-diffusion은 subthreshold hump 특성의 주된 요인이다. 이와 같은 문제점을 해결하기 위해 active edge rounding process와 channel dopant compensation의 implantation을 이용하여 subthresold hump 특성 개선을 연구하였다. 본 연구는 STI 공정에 필요한 wafer와 phosphorus를 함유한 wafer를 한 chamber 안에서 auto-doping하는 방법을 이용하여 subthresold hump 특성을 구현하였다. phosphorus를 함유한 wafer에서 빠져나온 phosphorus가 STI 공정중인 wafer로 침투하여, active edge 부분의 channel dopant인 boron 농도를 상대적으로 낮춰 active edge 부분의 가 감소하고 leakage current를 증가시킨다. transistor의 channel length, gate width이고, wafer#No가 클수록 phosphorous를 함유한 wafer까지의 거리는 가까워진다. wafer #01은 hump 특성이 없고, wafer#20은 에서 심한 subthreshold hump 특성을 보였다. channel length 고정, gate width를 ~으로 가변하여 width에 따른 영향을 실험하였다. active 부분에 대한 SCM image로 확인된 phosphorus에 의한 active edge 부분의 boron 농도 감소와 gate width vs curve에서 확인된 phosphorus에 의한 감소가 narrow width로 갈수록 커짐을 확인하였다.

  • PDF

여자 중·고등학생의 교복평가와 교복변형 - 인천광역시를 중심으로 - (Evaluative Criteria and Modification of Girls' School Uniforms - Focused on the Middle and High School Students in Incheon -)

  • 정혜원;정인순
    • 한국의류산업학회지
    • /
    • 제7권2호
    • /
    • pp.179-186
    • /
    • 2005
  • Girls' school uniform evaluative criteria and their uniform modification were investigated. The data were collected by questionnaire from 579 middle and high school girls living in Incheon during the fall of 2003. The uniform evaluative criteria consisted of five dimensions: aesthetics, comfort, economy, management, and status concealment factor. The uniform evaluative criteria were used to cluster the students into five groups: economic, practical, aesthetic, negative, and active. The uniform modifications were investigated in regard to sleeve length, sleeve width, breast width, jacket length, skirt length, hip width, and waist width. The aesthetic and the active groups intended to modify uniforms less in sleeve length and skirt length than the other three groups. There were significant differences in the uniform modifications among demographics: school years, height, weight, spending money, satisfaction/dissatisfaction with spending money, and clothing expenditures.

IEEE 802.11 무선 LAN의 성능분석에 관한 연구 (A Study on The Performance Analysis of IEEE 802,11 Wireless LAN)

  • 홍성철;배성수;오영환
    • 대한전자공학회논문지TC
    • /
    • 제37권2호
    • /
    • pp.7-16
    • /
    • 2000
  • 본 논문에서는 p-persistent CSMA 방식의 IEEE 802.11 MAC 계층 프로토콜을 모델링 하였다. 그리고 renewal 이론을 적용하여 수학적으로 분석한 Basic CSMA/CA 프로토콜, CTS/RTS 프로토콜 그리고 은닉 노드를 고려한 Basic CSMA/CA 등의 성능분석모델을 제안하였다. 제안한 분석 모델을 이용하여 throughput을 구한 결과, active 노드 수가 적거나 패킷의 길이가 짧을 때는 Basic CSMA/CA 프로토콜 방식이, active 노드 수가 많거나 패킷의 길이가 길 때는 CTS/RTS 프로토콜 방식이 우수하였다. 또한 active 노드 수가 적은 경우가 많은 경우 보다 은닉 노드의 영향을 적게 받았다.

  • PDF

엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교 (Reliability of Three Methods for Measuring Length of Iliotibial Tract)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.

Studies on the Width of Rectangular Channels of Fuel Cell Bipolar Plate Using FDM 3D Printer with PLA Filament

  • Kim, Jae-Hyun;Jin, Chul-Kyu
    • 한국산업융합학회 논문집
    • /
    • 제24권6_1호
    • /
    • pp.683-691
    • /
    • 2021
  • Bipolar plates with channel width of 0.5 mm, 0.4 mm, and 0.3 mm respectively were printed using a 3D printer. The shape of three b ipolar plates was rectangular, the channel depth was 0.5 mm, and the thickness of base was 0.5 mm. The bipolar plate with channel width of 0.5 mm had 45 channels, and their active area was 44.5 mm × 50 mm. The bipolar plate with channel width of 0.4 mm had 57 channels and its active area was 45.2 mm × 50 mm, and the bipolar plate with channel width of 0.3 mm had 75 channels and its active area was 44.7 mm × 50 mm. The bipolar plates were printed using PLA filament. The cross-sectional lengths of the bipolar plates with channel widths of 0.5 mm and 0.4 mm were identical by 96% of the designed cross-sectional length. Whereas the bipolar plate with a channel length of 0.3 mm had a large difference of 25% from the designed cross-sectional length.