• Title/Summary/Keyword: Active failure

Search Result 401, Processing Time 0.028 seconds

A Risk Evaluation Model of Power Distribution Line Using Bayesian Rule -Overhead Distribution System- (베이즈 규칙을 활용한 배전선로 위험도 평가모델 -가공배전분야-)

  • Joung, Jong-Man;Park, Yong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.870-875
    • /
    • 2013
  • After introducing diagnosis equipment power failure prevention activities for distribution system have become more active. To do facility diagnosis and maintenance work more efficiently we need to evaluate reliability for the system and should determine the priority line with appropriate criteria. Thus, to calculate risk factor for the power distribution line that are composed of many component facilities its historical failure events for the last 5 years are collected and analysed. The failure statics show that more than 60% of various failures are related to environment factors randomly and about 20% of the failures are refer to the aging. As a strategic evaluation system reflecting these environmental influence is needed, a system on the basis of the probabilistic approach related statical variables in terms of failure rate and failure probability of electrical components is proposed. The figures for the evaluation are derived from the field failure DB. With adopting Bayesian rule we can calculate easily about conditional probability query. The proposed evaluation system is demonstrated with model system and the calculated indices representing the properties of the model line are discussed.

Study on the Beam Pattern Compensation with Planar Active Phased Array Antenna (평면형 능동위상 배열안테나 빔 패턴 보상에 관한 연구)

  • Chon, Sang-Mi;Na, Hyung-Ki;Ahn, Chang-Soo;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.217-222
    • /
    • 2014
  • This paper discusses about the beam pattern distortion caused by the failures of some antenna modules in the active array antenna and analyses the possibility of improvement through applying the beam pattern compensation method previously studied. The beam pattern distortion which is mostly represented as an increase of the sidelobe level, can be suppressed through re-synthesizing each module's magnitude and phase. This method was applied to the prototype of active array antenna system, and the results of antenna pattern distortion and compensation were analyzed and measured in the Near Field Chamber. Array failures are generally divided into random TR module failures and TRU(TR Unit: combination of TR modules, Beam Computation module, Power supply module) failures. The results of beam pattern compensation were analyzed in each failure and compared to the results of the simulation. The beam pattern compensation results applied to the real active antenna array system showed the similar to the simulation results. Consequently, it was verified the beam pattern could be compensated with the magnitude and phase adjustment of other normal antenna modules.

Open Switch Fault Tolerance Control of Active NPC Inverters With HF/LF Modulation (HF/LF 변조를 적용한 Active NPC 인버터의 개방 고장 허용 제어)

  • Jung, Won Seok;Kim, Ye-Ji;Kim, Seok-Min;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • This paper presents an open-fault tolerance control method for active neutral point clamped (ANPC) inverter with high frequency/low frequency (HF/LF) modulation. By applying the ANPC inverter with SiC MOSFETs and Si IGBTs, the system efficiency and performance can be improved compared to a Si-based inverter. HF/LF modulation is used for a megawatt-scale inverter to minimize the commutation loop. The open-switch failure in megawatt-scale inverter causes severe damage to load and huge expenses when the inverter has been shut-down. The proposed tolerance control of open-switch failure provides continuous operation and improved reliability to the ANPC inverter. The effectiveness of the proposed fault tolerance control is verified by simulation results.

Development of Robot Mechanism for Cleaning and Inspection of Live Line Insulator (송전선로 활선 애자 청소 및 점검용 로봇 기구부의 개발)

  • Park, Joon-Young;Cho, Byung-Hak;Byun, Seung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.421-423
    • /
    • 2005
  • Power transmission lines have been playing a key role as the mainstay of national industry. When a power failure occurs, it can have severe effects on national security as well as national industry and economy. In this paper, we consider an insulator failure, which is one of the main causes of such a power failure. In spite of its importance, however, a shortage of manpower in the insulator maintenance field is getting more serious due to working environments with a high voltage and a high place. For this reason, a new active maintenance technique using a robot system is required to prevent such an insulator failure. In this paper, a new robot mechanism for insulator cleaning and inspection was developed. We confirmed its effectiveness through experiments.

  • PDF

Immunogenicity of botulinum toxin

  • Wee, Syeo Young;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.12-18
    • /
    • 2022
  • Botulinum toxin treatment is the most common non-surgical cosmetic treatment. Although there are many available treatments using botulinum toxin, their effects are temporary and repeated injections are required. These frequent injections can trigger an immunological response. In addition, botulinum toxin acts as an antigen in the body; thus, its effect disappears progressively due to this immunological reaction, which may cause treatment failure. Active botulinum toxin consists of a core neurotoxin and complexing proteins, the exact effects of which remain unclear. However, the complexing proteins are closely related to the immune response and the formation of neutralizing antibodies. Since neutralizing antibodies can lead to treatment failure, their formation should be prevented. Furthermore, various methods of detecting neutralizing antibodies have been used to predict treatment failure.

In Vitro Adenosine Triphosphate Based Chemotherapy Response Assay in Gastric Cancer

  • Park, Seul-Kee;Woo, Yang-Hee;Kim, Ho-Geun;Lee, Yong-Chan;Choi, Sung-Ho;Hyung, Woo-Jin;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.10 no.4
    • /
    • pp.155-161
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the reliability and the clinical applicability of the adenosine-triphosphate-based chemotherapy response assay (ATP-CRA) as a method of determining in vitro chemosensitivity in patients with gastric cancer. Materials and Methods: A total of 243 gastric cancer tissue samples were obtained from gastrectomies performed between February 2007 and January 2010. We evaluated the effectiveness of the ATP-CRA assay in determining the chemosensitivity of gastric cancer specimens using eleven chemotherapeutic agents - etoposide, doxorubicin, epirubicin, mytomicin, 5-fluorouracil, oxaliplatin, irinotecan, docetaxel, paclitaxel, methotraxate, and cisplatin - for chemosensitivity studies using ATP-CRA. We assessed the failure rate, the cell death rate, and the chemosensitivity index. Results: The failure rate of ATP-CRA was 1.6% (4/243). The mean coefficient of variation for triplicate ATP measurements was 6.5%. Etoposide showed the highest cell death rate (35.9%) while methotrexate showed the lowest (16.6%). The most active chemotherapeutic agent was etoposide, which most frequently ranked highest in the chemosensitivity test: 31.9% (51/160). Oxaliplatin was more active against early gastric cancers than advanced gastric cancers, whereas docetaxel was more active against advanced cancers. The lymph node negative group showed a significantly higher cell death rate than the lymph node positive group when treated with doxorubicin, epirubicin, and mitomycin. Conclusions: ATP-CRA is a stable and clinically applicable in vitro chemosensitivity test with a low failure rate. The clinical usefulness of ATP-CRA should be evaluated by prospective studies comparing the regimen guided by ATP-CRA with an empirical regimen.

Development of a Numerical Model Considering Active Tsunami Generation (능동적 지진해일 생성을 고려한 지진해일 수치모형 개발)

  • Jung, Taehwa;Hwang, Sooncheol;Son, Sangyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.4
    • /
    • pp.160-167
    • /
    • 2021
  • Seabed deformation due to the fault failure have both a spatial variation and temporal history. When the faulting process initiates at a certain point beneath seabed, the failure spreads out to neighboring points, resulting in temporal changes of deformation. In particular, such a process induces tsunami waves from the vertical motion of seabed. The uprising speed of seabed affects the formation of initial surface profile, eventually altering the arrival time and runup of tsunamis at the coast. In this work, we developed a numerical model that can simulate the generation and propagation of tsunami waves by considering the horizontal and vertical changes of seabed in an active and dynamic manner. For the verification of the model, it was applied to the 2011 Tohoku-oki earthquake in Japan and the results confirmed that the accuracy was improved compared to the existing passive and static model.

Fault Tolerant Control of Magnetic Bearings with Force Invariance

  • Na, Uhn-Joo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.731-742
    • /
    • 2005
  • A magnetic bearing even with multiple coil failure can produce the same decoupled magnetic forces as those before failure if the remaining coil currents are properly redistributed. This fault-tolerant, force invariance control can be achieved with simply replacing the distribution matrix with the appropriate one shortly after coils fail, without modifying feedback control law. The distribution gain matrix that satisfies the necessary constraint conditions of decoupling linearized magnetic forces is determined with the Lagrange Multiplier optimization method.

Leverage and Corporate Failure: Analysis of Leverage Impact according to Company Size through Survival Analysis (레버리지와 기업실패: 생존분석을 응용한 기업규모에 따른 레버리지 영향분석)

  • Kim, Bong-Min;Kim, Byoung-Gon;Kim, Dong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.275-284
    • /
    • 2021
  • Survival analysis was used to analyze whether there is a difference in the effect of leverage on corporate failure according to the firm size. A total of 25,250 (year-company) companies listed on the Korea Stock Exchange and KOSDAQ market from 1999 to 2019 were analyzed. First, the increase in leverage generally acts as a factor that increases the possibility of corporate failure. On the other hand, the increase in the trade payable ratio lowered the possibility of failure of the company. The increase in corporate trade payable was perceived as a factor in reducing the possibility of corporate failure because it was considered the active development of business activities or active use of interest-free debt rather than leading to an increase in corporate risk. Second, a higher leverage ratio and trade payable ratio in large firms lowered the possibility of corporate failure. In the SMEs, all types of leverage increases are a factor that increases corporate failure. Overall, the effect of leverage on corporate failure differs according to the size of the company.

Analysis of Sinkhole Formation over Abandoned Mine using Active-Passive-Active Finite Elements (폐광지역에서의 싱크홀 발생 규명을 위한 Active-Passive-Active 유한요소 기법 연구)

  • Deb Debasis;Shin Hee-Soon;Choi Sung O.
    • Tunnel and Underground Space
    • /
    • v.14 no.6 s.53
    • /
    • pp.411-422
    • /
    • 2004
  • Sinkhole subsidence occurs over abandoned mine workings and can be detrimental to human lives, damage to properties and other surface structures. In this study, simulation of sinkhole development process is performed using special finite element procedure. Especially, creation of mine voids due to roof falls and generation of goaf from broken rocks are simulated using active-passive-active finite elements. An active or solid element can be made passive or void once the tensile failure criterion is satisfied in the specified sinkhole formation zone. Upon completion of sinkhole development process, these passive elements in again be made active to simulate goal region. Several finite element models are analyzed to evaluate the relationships between sinkhole formation with width of gallery. depth of mine, roof condition and bulking factor of roof rocks. This study demonstrates that the concept of passive elements in numerical analysis can be used effectively for analyzing sinkhole formation or roof fall phenomenon in general.