Proceedings of the Korea Inteligent Information System Society Conference
/
2001.01a
/
pp.265-271
/
2001
It is highly for the research in artificial intelligence area to be able to manage knowledge as human beings do. One of the fantastic natures that human knowledge management systems have is being active. Human beings actively manage their knowledge, solve conflicts and make inference. It makes a major difference from artificial intelligent systems. This paper focuses on the discussion of the features of that human knowledge systems, which underlies the active nature. With the features extracted, further research can be done to construct a suitable infrastructure to facilitate these features to build a man-made active knowledge management system. This paper proposed 10 features that human beings follow to maintain their knowledge. We believe it will advance the evolution of active knowledge management systems by realizing these features with suitable knowledge representation/decision models and software agent technology.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2008.04a
/
pp.171-176
/
2008
Active suspension controls stiffness and damping between unsprung mass and sprung mass in order to increase the ride quality. However, to increase the riding quality, the handling quality should be decreased and the rattle space should be increased. So, active suspension should cope with these conflict conditions. Therefore its actuating devices have to produce sufficient actuating force and have sufficiently short response time. In this paper, the dynamic characteristics of 1/4 car model with an active suspension is studied according to hydraulic design variables. The active suspension consists of a hydraulic servo valve and a hydraulic cylinder. It shows better performance when it has more powerful and faster actuator.
Journal of the Korea Institute of Military Science and Technology
/
v.12
no.4
/
pp.500-507
/
2009
This paper presents a novel method which can detect a target in IR image for active protection system. The target in IR image for the active protection system is small, moreover it moves with enormous speed. The proposed algorithm is comprised of robust clutter rejection methods and target optimized detection algorithms for small target, and an advanced method of selecting a final target position in target area, it can work in some milliseconds. The proposed algorithm provides the active protective system with more correct positions than those of radar, so that helps the active protection system can defense all threats with the utmost precision.
We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.5
no.2
/
pp.61-67
/
2012
In this paper, In this paper, we consider a dynamic range in the frequency converter to obtain a high conversion gain and linearity while operating area proposed to broaden the design. Super-heterodyne RF Front-End style was applied to the active mixer stage, GaAs devices were used. Circuit design easy and simple forms benefit circuit is constructed in the drain mixer, passive mixer with the operating area were compared and analyzed. The simulation results of the conversion gain of 2.4dB and 0.2dBm about a gain-compression point, and showed the dynamic range of 71.9dB, when compared with passive mixers, dynamic range of approximately 6dB improvement was identified. Measurements of an approximately 2dB conversion gain and-1.0dBm of the gain-compression point, and confirmed that the active area of 71.1dB. When compared with passive mixers, dynamic range of is reduced by approximately 8dB has been improved.
Jeon, Woong-Gi;Kim, Tae-Yun;Kim, Sung Jun;Choi, Heung-Kuk;Kim, Kwang Gi
Journal of Korea Multimedia Society
/
v.16
no.7
/
pp.829-840
/
2013
In this paper, we propose a new lung segmentation method for chest x-ray images which can take both global and local properties into account. Firstly, the initial lung segmentation is computed by applying the active shape model (ASM) which keeps the shape of deformable model from the pre-learned model and searches the image boundaries. At the second segmentation stage, we also applied the localizing region-based active contour model (LRACM) for correcting various regional errors in the initial segmentation. Finally, to measure the similarities, we calculated the Dice coefficient of the segmented area using each semiautomatic method with the result of the manually segmented area by a radiologist. The comparison experiments were performed using 5 lung x-ray images. In our experiment, the Dice coefficient with manually segmented area was $95.33%{\pm}0.93%$ for the proposed method. Effective segmentation methods will be essential for the development of computer-aided diagnosis systems for a more accurate early diagnosis and prognosis regarding lung cancer in chest x-ray images.
Background Scalp defects may be caused by various etiological factors, and they represent a significant surgical and aesthetic concern. Various surgical techniques can be applied for reconstructive work such as primary closure, skin grafting, pedicled or free flaps. In this article, the authors share their clinical experience with scalp operations using the technique of local flaps and discuss the application of this method from the perspective of not only the size of the defect, but also in relation to the anatomical area, quality of surrounding tissue, and patient's condition. Methods During the period from December 2007 to December 2012, 13 patients with various scalp defects, aged 11 to 86 years, underwent reconstruction with local pedicle flaps. The indications were based on the patients' condition (age, sex, quality of surrounding tissue, and comorbidities) and wound parameters. Depending on the size of the defects, they were classified into three groups as follows: large, 20 to 50 $cm^2$; very large, 50 to 100 $cm^2$; extremely large, 100 $cm^2$. The location was defined as peripheral (frontal, temporal, occipital), central, or combined (more than one area). We performed reconstruction with 11 single transposition flaps and 1 bipedicle with a skin graft on the donor area, and 2 advancement flaps in 1 patient. Results In all of the patients, complete tissue coverage was achieved. The recovery was relatively quick, without hematoma, seroma, or infections. The flaps survived entirely. Conclusions Local flaps are widely used in scalp reconstruction since they provide healthy, stable, hair-bearing tissue and require a short healing time for the patients.
The purpose of this study was to investigate the fine structural modifications of fibroblasts in the coronal region of inflamed human pulps from carious teeth. Six untreated human teeth with large carious lesions and two normal teeth as control were selected from male and female patients between the ages of 20 and 39. The teeth were divided into 4 groups by light microscopic findings: the normal control group, the chronic inflammatory cell-appeared group, the acute and chronic inflammatory cell-appeared group, and the total necrosis group. All tissues were fixed in 2.5% glutaraldehyde in 0.1M sodium cacodylate buffer at pH 7.4 and 1% osmic acid in same buffer. They were embedded in Epon 812. The ultrathin sections were stained conventionally and examined with a AEI Corynth 500 electron microscope. The results were as follows; 1. The fibroblasts of the normal pulps were almost in a quiescent state. 2. The active and the quiescent fibroblasts were found in the pulps of the chronic inflammatory cell-appeared group. Lymphocytes and plasma cells were also seen scattered among these fibroblasts. 3. In the pulps of the acute and chronic inflammatory cell-appeared group, active, degenerative and necrotic fibroblasts were found in the PMN appeared area. And all the fibroblasts in the fibrosis area were active. In the area of chronic inflammatory cellular infiltration, almost all the fibroblasts were active, but seldom were quiescent fibroblasts observed. Some fibroblasts in the pulps of two teeth had large vacuoles that contained banded collagen fibrils. The phagosomes had small beaded vesicles or large lysosome-like varicosity. In two of the teeth, microorganisms were present and two morphological shapes were identified, a rod and a coccus. 4. Vacuolar, vesicular, lamellar, fibrous and myelin structures were observed in the pulp of the total necrosis group, and cocci were also seen.
Journal of The Geomorphological Association of Korea
/
v.26
no.4
/
pp.107-121
/
2019
This study documents the distribution of (active) faults around the southern part of the Yangsan Fault and the Moryang Fault and the middle part of the Dongrae Fault. For this objective, we extracted lineaments and fault-related landforms by analyzing aerial photos and digital elevation models and with the result of fieldwork on fault-relating features of the Quaternary landforms. Geomorphological techniques for active fault study are not only preliminary but also essential methods because, in general, an active fault can be defined only with fault-deformed Quaternary sediments when there is no way to detect precise timing of faulting. Therefore, geomorphological interpretation in active fault research is necessary to determine the extent, direction, termination and timing of fault. This study addresses the results of such geomorphological analysis and geomorphic markers for tracing the active faults in the study area. It is plan to investigate with geophysical and geological techniques the sites referred in this study.
Proteins combine with other materials to achieve their function and have similar function if their active sites are similar. Thus we can infer the function of protein by identifying the binding area of proteins. This paper suggests the novel method to select binding area of protein using MCL (Markov Cluster) algorithm. We construct the distance matrix from surface residues distance on protein. Then this distance matrix is transformed to connectivity matrix for applying MCL process. We adopted Catalytic Site Atlas (CSA) data to evaluate the proposed method. In the experimental result using CSA data (94 selected single chain proteins), our algorithm detects the 91 (97%) binding area near by active site of each protein. We introduced a new geometrical features and this mainly contributes to reduce the time to analyze the protein by selecting the residues near by active site.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.