• 제목/요약/키워드: Active State

검색결과 1,734건 처리시간 0.026초

영구자석 동기모터 진동 및 과전류 저감을 위한 능동단락회로 제어 기법 (Active Short Circuit Control Method to Reduce Overcurrent and Oscillation Current in PMSM)

  • 최종원;김윤재
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.339-347
    • /
    • 2022
  • This study proposes the mitigation method for overcurrent and oscillation motor current in an active short-circuit operation. This operation is attracting attention as the safe state of electric vehicle traction inverters. However, the active short-circuit operation generates oscillation and overcurrent of motor currents during a transient state. The proposed method uses two different safe states in PMSM, such as active short circuit and freewheeling. The active short circuit is used for safe state in a steady state. To reduce the overshoot and oscillation, a freewheeling state is injected between active short-circuit operation by comparing the motor phase current with an analytically calculated steady-state motor current. Freewheeling state is only used in a transient state. The performance is demonstrated through simulations and experimental results. The peak current of the motor was reduced from 52 A to 40 A, and oscillation time was reduced.

반능동 현가시스템의 Robust 제어 법칙 (A Robust Semi-active Suspension Control Law)

  • 이경수;서명원;오태일
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.117-126
    • /
    • 1994
  • This paper deals with a robust semi-active control algorithm which is applicable to a semi-active suspension with a multi-state damper. Since the controllable damping rates are discrete in case of a multi-state semi-active damper, the desired damping rate can not be produced exactly even if force-velocity relations of a multi-state semi-active damper is completely known. In addition, damping characteristics of the semi-active dampers are different from damper to damper. A robust nonlinear control law based on sliding control is developed. The main objective of the proposed control strategies is to improve ride quality by tracking the desired active force with a multi-state damper of which the force-velocity relations are "not" completely known. The performance of th proposed semi-active control law is numerically compared to those of the control law based on a bilinear model and a passive suspension. The proposed control algorithm is robust to nonlinear characteristics and uncertainty of the force-Velocity relations of multi-state dampers.

  • PDF

연속적 분석법을 통한 어머니와 유아의 상호작용 연구 (A Sequential Analysis of Mother-Infant Interaction)

  • 최진경
    • 아동학회지
    • /
    • 제6권1호
    • /
    • pp.3-16
    • /
    • 1985
  • The purpose of this study was the application of sequential analysis to mother-infant interaction data, with particular reference to goodness of fit. The subjects of this study were 22 7- to 16-month-old infants(12 girls and 10 boys) and their mothers. Each mother-infant dyad was videotaped in a 5-min free-play session in the playroom. The videotaped data was transcribed on the behavioral checklist every 3 seconds. The recorded raw data were lagged by one time interval (3 sec.). Transitional probabilities from behavior at time t-1 to behavior at time t were gathered. The statistical analysis of frequency data and transitional probabilities consisted of Z test, t test, and sign test. It was found that regarding 1) direction of effect: the transitional probability of infant vocalization following maternal vocalization was significantly higher than the reverse; the transitional probability of a 'Coacting State' following a 'Mother Active State' was significantly higher than the reverse; the probability of a 'Mother Active State' following 'Quiescent State' was significantly higher than that of a 'Coacting State' following an 'Infant Active State'; 2) sex differences: male infants' transitional probability from an 'Infant Active State' to a 'Quiescent State' was significantly higher than that of female infants; 3) age differences: more than younger infants older infants had higher transitional probabilities from a 'Mother Active State' to a 'Coacting State', from a 'Parallel State' to a 'Coacting State', and from a 'Quiescent State' to a 'Parallel State'. These showed goodness of fit for sex and age differences, particularily for direction of effect.

  • PDF

Mobile IPv6상에서 적응적 액티브 타이머를 고려한 IP 페이징 (IP Paging with an Adaptive Active Timer in Mobile IPv6)

  • 이보경
    • 한국정보과학회논문지:정보통신
    • /
    • 제31권5호
    • /
    • pp.482-489
    • /
    • 2004
  • Mobile IP에서 이동노드의 불필요한 위치 등록으로 인하여 발생되는 네트워크 시그널링 오버헤드를 줄이고자 IETF에서는 IP 페이징 기법을 제안하였다. IP 페이징 기법을 지원하기 위하여 이동노드는 active on, active off, idle 중 한가지 상태를 유지하여야 한다. Active on 상태는 이동노드에 데이터 세션이 형성되어 데이타를 수신하거나 또는 송신하는 상태를 말한다. 이때 이동노드가 데이타의 송수신을 완료하고 나면 이동노드는 active off 상태로 바뀌게 되며 active timer를 구동한다. 그 후 일정시간 동안 이동노드가 데이타를 송수신하지 않고 페이징 영역 간 이동이 발생하지 않으면 active timer가 만료된다. 이때 이동노드의 상태는 idle 상태로 바뀌게 된다 기존의 IP 페이징 기법에서는 고정된 active timer 값을 사용하고 있으나 본 논문에서는 이동노드의 이동성 및 트래픽 특성에 따라 active timer 값을 동적으로 설정하여 불필요한 위치갱신 작업을 줄일 수 있는 IP 페이징 기법을 제안한다. 또한 본 논문의 제안기법과 기존의 IP 페이징 기법간의 위치 갱신 및 페이징 비용에 대한 수학적 모델을 수립하고 성능평가를 수행한다. 이를 이용하여 성능 분석을 수행한 결과 기존 기법에 비하여 제안 기법이 보다 효율적임을 보여주고 있다.

A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter

  • Wan, Zhiqiang;Xiong, Jian;Lei, Ji;Chen, Chen;Zhang, Kai
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1286-1294
    • /
    • 2015
  • Capacitor current feedback active damping is extensively used in grid-connected converters with an LCL filter. However, systems tends to become unstable when the digital control delay is taken into account, especially in low switching frequencies. This paper discusses this issue by deriving a discrete model with a digital control delay and by presenting the stable region of an active damping loop from high to low switching frequencies. In order to overcome the disadvantage of capacitor current feedback active damping, this paper proposes a modified approach using grid current and converter current for feedback. This can expand the stable region and provide sufficient active damping whether in high or low switching frequencies. By applying the modified approach, the active damping loop can be simplified from fourth-order into second-order, and the design of the grid current loop can be simplified. The modified approach can work well when the grid impedance varies. Both the active damping performance and the dynamic performance of the current loop are verified by simulations and experimental results.

A Semi-Markov Decision Process (SMDP) for Active State Control of A Heterogeneous Network

  • Yang, Janghoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권7호
    • /
    • pp.3171-3191
    • /
    • 2016
  • Due to growing demand on wireless data traffic, a large number of different types of base stations (BSs) have been installed. However, space-time dependent wireless data traffic densities can result in a significant number of idle BSs, which implies the waste of power resources. To deal with this problem, we propose an active state control algorithm based on semi-Markov decision process (SMDP) for a heterogeneous network. A MDP in discrete time domain is formulated from continuous domain with some approximation. Suboptimal on-line learning algorithm with a random policy is proposed to solve the problem. We explicitly include coverage constraint so that active cells can provide the same signal to noise ratio (SNR) coverage with a targeted outage rate. Simulation results verify that the proposed algorithm properly controls the active state depending on traffic densities without increasing the number of handovers excessively while providing average user perceived rate (UPR) in a more power efficient way than a conventional algorithm.

1/2 궤도차량에 대한 반능동 현수장치 제어 알고리즘들의 성능평가 (Performance Evaluation of Control Algorithms for 1/2 Tracked Vehicle with Semi-Active Suspension System)

  • 윤일중;임재필;신휘범;이진규;신민재
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.139-147
    • /
    • 2001
  • 2 DOF half-car model with 6 semi-active suspension units is utilized to evaluate the tracked vehicle dynamic performance simulated by several suspension control algorithms. The target of this research is to improve the ride comfort to maintain operator's handling capability when the tracked vehicle travels fast on the rough road. The control algorithms for suspension systems, such as full state feedback active, full state feedback semi-active, sky-hook active, sky-hook semi-active, and on-off systems, are evaluated and analyzed in view point of ride comfort. The dynamic performances of vehicle are expressed and evaluated by vibratory characteristic evaluation curves, performance indices and frequency characteristic curves. The simulation results show that the performances of sky-hook algorithms for ride comfort nearly follow those of full state feedback algorithms and on-off algorithm is recommendatory when the vehicle runs relatively fast.

  • PDF

DEVCS 모델을 사용한 심근 활성화과정의 시뮬레이션 (A Simulation of the Myocardium Activation Process using the Discrete Event Cell Space Model)

  • 김광년;정동근;김기련;최병철;이정태;전계록
    • 한국시뮬레이션학회논문지
    • /
    • 제13권4호
    • /
    • pp.1-16
    • /
    • 2004
  • The modelling and simulation of the activation process for the heart system is meaningful to understand special excitatory and conductive system in the heart and to study cardiac functions because the heart activation conducts through this system. This thesis proposes two dimensional cellular automaton(CA) model for the activation process of the myocardium and conducted simulation by means of discrete time and discrete event algorithm. In the model, cells are classified into anatomically similar characteristic parts of the heart and each of cells has a set of cells with preassigned properties. Each cell in this model has state variables to represent the state of the cell and has some state transition rules to change values of state variables executed by state transition function. The state transition rule is simple as follows. First, the myocardium cell at rest stay in passive state. Second, if any one of neighborhood cell in the myocardium cell is active state then the state is change from passive to active state. Third, if cell's state is an active then automatically go to the refractory state after activation phase. Four, if cell's state is refractory then automatically go to the passive state after refractory phase. These state transition is processed repeatedly in all cells through the termination of simulation.

  • PDF

능동과 반능동 현가장치로 된 전차량 모델에 대한 스카이훅 제어기의 비교 평가 (Comparative Evaluation of Sky-Hook Controllers for a Full Car Model with Active or Semi-Active Suspension Systems)

  • 윤일중;임재필
    • 제어로봇시스템학회논문지
    • /
    • 제7권7호
    • /
    • pp.614-621
    • /
    • 2001
  • The controllers for a full car 7-DOF model with 4 active or semi-active suspension units are designed and evaluated in this research. The control algorithms for suspension systems, such as full state feedback active, full state feedback semi-active, sky-hook active, sky-hook semi-actvie, and on-off suspension systems, are analyzed and evaluated with respect to ride comfort. The vehicle dynamic performances are expressed by response curves to a bump input, performance indices for asphalt road input, and frequency characteristic curves. Heaving, rolling, and pitching inputs are applied to the vehicle dynamic system to evaluate frequency characteristics. The simulation results show that the ride quality of the sky-hook controller approaches that the full state feedback controller more closely in semi-active suspension system than in active suspension system. For the implementation of a vehicle with sky-hook suspension control systems in this paper, 7 velocity sensors are required to measure the states.

  • PDF

Advanced Features of Static Inverter and Their Influence on Rail Infrastructure and Vehicle Maintenance

  • Bachmann, G.;Wimmer, D.
    • International Journal of Railway
    • /
    • 제1권3호
    • /
    • pp.94-98
    • /
    • 2008
  • Static inverters are essential devices onboard of rolling stock. State-of-the-art static inverters have an impact on both rail infrastructure and vehicle maintenance due to their new topology with new features. The paper describes two important aspects as examples of new features available in state-of-the-art static inverters: active input current control and the effects on the rail infrastructure as well as the detection of the state of charge and the state of health of batteries to simplify vehicle maintenance.

  • PDF