• 제목/요약/키워드: Active Push

검색결과 79건 처리시간 0.035초

K-band용 Push-Push 유전체 공진 발진기의 설계 및 제작 (Design and Construction of a Push-Push Dielectric Resonator Oscillator at K-band)

  • 이주열;이찬주;홍의석
    • 전자공학회논문지A
    • /
    • 제29A권2호
    • /
    • pp.8-17
    • /
    • 1992
  • In this paper a push-push oscillator using DR (dielectric resonator) at K-band is designed and constructed. Two identical oscillators are arranged in a push-push configuration that has the frequency of oscillator that is twice frequency each oscillator. A dielectric resonator is placed at the input of an active two-port device(FET) yielding a stable frequency source. The oscillators realized with this technique exhibit excellent spectral purity and cancellation of fundamental frequency.

  • PDF

능동클램프회로를 갖는 전류공급 Push-Pull형 고주파공진 DC-DC 컨버터의 특성평가 (A Characteristic Estimation of Current fed Push Pull Type High Frequency Resonant DC-DC Converter with Active Clamp Circuits)

  • 오경섭;남승식;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.517-524
    • /
    • 2004
  • In this paper, a novel zero-voltage-switching(ZVS) resonant DC-DC converter is proposed. It is composed of two symmetrical active-clamped circuits, the converter can be achieve ZVS in each switches. Also, active clamp capacitor ratios($\alpha$) of proposed circuit can be reduce a peak stress of switching voltage for each main switch. Simulation results using Pspice 9.2 ver and $C^{++}$ characteristic analysis show a provement for the validity of theoretical analysis. The analysis of the proposed Current-Fed Push Pull type DC-DC converter is generally described by using normalized parameter, and achieved an evaluated characteristic values which is needed to design a circuit. We confirm a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

스마트 관광용 위치기반의 PPL 서비스 플랫폼 설계 (Design of PPL Service Platform for Smart Travelling based on Location)

  • 강민구
    • 스마트미디어저널
    • /
    • 제5권4호
    • /
    • pp.138-142
    • /
    • 2016
  • 본 논문에서는 시청자가 스마트 디바이스에 마킹한 위치정보를 기반으로 PPL(Product Placement) 데이터베이스와 연동하는 스마트 관광 서비스 플랫폼을 제안하고자 한다. 이러한 위치기반의 비디오 클립 플랫폼은 LTE와 비콘에 의한 위치인식 기반의 촬영지 드라마 영상을 Active Push 플랫폼과 스마트 키오스크 사이니지 연동 플랫폼을 설계한다. 이러한 스마트 PPL-DB 플랫폼은 인터렉티브한 태그 동기화와 중간 비디오 클립 간 PPL 사진과 동영상 형태의 다양한 카테고리별, 위치별, 상품별 및 선호도별 PPL DB가 연동하게 된다.

Immediate Effects of Flexi-bar Exercise With Knee Push-up Plus on Shoulder Joint Position Sense and Muscle Activity in Subjects With Scapular Winging

  • Kim, Seok-hyun;Cynn, Heon-seock;Baik, Seung-min
    • 한국전문물리치료학회지
    • /
    • 제28권4호
    • /
    • pp.256-265
    • /
    • 2021
  • Background: Individuals with scapular winging may have proprioceptive dysfunction which is important for motor control and causes shoulder instability. Reduced serratus anterior (SA) and lower trapezius (LT) muscle activity accompanied by over-active upper trapezius (UT), and pectoralis major (PM) may be contributing factors. Flexi-bar (FB) exercise may be used to increase joint position sense (JPS) and alter the target muscle activities. Objects: This study aimed to investigate the immediate effects of flexi-bar exercise prior to knee push-up plus (FPK) versus knee push-up plus (KPP) on JPS and muscle activity of SA, LT, UT, and PM in subjects with scapular winging. Methods: Eighteen subjects with scapular winging were recruited. JPS was investigated at baseline, after KPP and after FPK. Passive and active JPS errors were calculated by isokinetic equipment. Surface electromyography was used to record muscle activities during KPP and FPK. One-way repeated-measures analysis of variance and post hoc analyses were used to analyze the JPS error measured at baseline, after KPP and after FPK. Paired t-tests were used to compare muscle activities between KPP and FPK. Results: Passive JPS error was significantly decreased after KPP (p = 0.005) and after FPK (p = 0.003) compared to the baseline. Active JPS error was also significantly decreased after KPP (p = 0.016) and after FPK (p = 0.012) compared to the baseline. There was no significant difference in the passive and active JPS errors between KPP and FPK. SA activity during FPK was significantly increased (p = 0.024), and LT activity during FPK was significantly increased (p = 0.006). There were no significant differences in the UT and PM activity. Conclusion: FB might be recommended to immediately improve passive and active JPS and to selectively increase SA and LT muscle activities during KPP in individuals with scapular winging.

능동클램프회로를 갖는 전류공급 Push-Pull형 고주파공진 DC-DC 컨버터 (A Current-Fed Push-Pull Type High Frequency resonant DC-DC Converter with an Active-clamp-circuits)

  • 오경섭;원재선;남승식;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.227-231
    • /
    • 2003
  • In This paper, A novel zero-voltage-switching(ZVS) resonant DC-DC converter is proposed. it is composed of two symmetrical active-clamped circuits, The converter can achieve each switchs ZVS. proposed circuit is active clamp capacitor Ratios can be reduce switching voltage stress of each main switch. Simulation results using Pspice ver 9.2 show that the prove the validity of theoretical analysis.

  • PDF

마비 환자를 위한 능동형 달하지 보조기의 개발 (Development of an Active Controlled Ankle-Foot-Orthosis for Paralysis Patients)

  • 황성재;김정윤;김영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.193-195
    • /
    • 2006
  • In this study, we developed an active controlled ankle-foot orthosis(AAFO) which can control the dorsiflexion/plantarflexion of the ankle joint during gait to prevent foot drop and toe drag for paralysis patients. To prevent dropping foot after heel strike, ankle joint was actively controlled to minimize forefoot collision with the ground. It was also controlled to provide toe clearance and to help push-off during late stance. The 3D gait analysis was performed on two healthy subjects equipped with the developed AAFO to compare with the normal gait and the conventional AFO gait. In the developed AAFO gait, differently from the conventional AFO gait, significant push-off was observed during pre-swing and the maximum flexion moment during pre-swing phase was similar to that of normal gait. A remarkable dorsiflexion also occurred during initial swing. These results indicated that the developed AAFO could have certain clinical benefits to prevent foot drop for paralysis patients, compared to conventional AFOs.

  • PDF

능동 클램프를 이용한 전류원 푸쉬풀 컨버터 (Active-clamp current-fed push-pull converter)

  • 김상식;권봉환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1006-1007
    • /
    • 2006
  • An active-clamp current-fed push-pull converter for the step-up application is proposed. The proposed converter is composed of active-clamp circuits and a voltage doubler rectifier. Thus, the voltage stress of the main switches is reduced and the output diodes are clamped to output voltage. Moreover, the output diodes can achieve zero current switching (ZCS) by the series resonance between resonant capacitors and leakage inductances. The prototype is designed for 350V/1.5kW with input voltage range $30{\sim}60V$. The theoretical analysis and experimental results are presented.

  • PDF

기능적 움직임 검사의 방법과 적용에 관한 연구 (The Study of Functional Movement in Healthy adults)

  • 이진;유태호;서우혁
    • 대한물리치료과학회지
    • /
    • 제24권1호
    • /
    • pp.49-58
    • /
    • 2017
  • Purpose: To determine the effect of Functional movement screen(FMS) of Healthy subjects. Method: 18 subjects were randomly assigned toFunctional movement screen test. To measure functional movement screen(deep squat, hurdle step, in line lunge, shoulder mobility reaching, active straight leg raise, trunk stability push up, rotary stability). Result: FMS scores were deep squat 2.61score, right hurdle step 2.67 score, lift hurdle step 2.83 score, in line lunge 2.83 score, right shoulder mobility 2.67 score, left shoulder mobility 2.61 score, right active straight-leg raise 3.00 score, left active straight-leg raise 3.00 score, trunk stability push up 2.33 score, rotary stability 1.94 score. Conclusion: FMS can improve functional movement in healthy adults.

  • PDF

정상 성인의 신체적 특성과 기능적 움직임 검사에 대한 융합적 상관관계 분석 (Convergence Correlation Analysis of Physical Characteristics and Functional Movement Screen in Healthy Adults)

  • 김현승;조성현
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.87-93
    • /
    • 2020
  • 본 연구는 신체적 특성과 기능적 움직임 검사(FMS)의 융합적 상관관계에 대해 알아보고자 한다. 연구대상자는 정상 성인으로 193명을 대상으로 단일측정하였다. 자료분석은 SPSS 26.0 Ver 프로그램으로 T-검증을 실시하였고, 각 변수들 간 피어슨 상관계수로 분석을 하였다. 분석결과, 검사 방법 중 능동 뻗은 다리 올림 검사와 몸통 안정성 푸쉬업 검사 영역에서 성별 간에 유의한 차이가 나타났다(P<.05). 어깨 가동성 검사와 능동 뻗은 다리 올림 검사 영역을 제외한 나머지 FMS의 검사에서 체지방률과 부적 상관관계가 있었다. 능동 뻗은 다리 올림에서 여성이 기능적 움직임의 질이 높았으며, 몸통 안정성 푸쉬업에서는 남성이 기능적 움직임의 질이 높았다. 그러므로 남성은 하지의 유연성을 보강해야하며, 여성은 상체 근력과 몸통의 안정성 운동을 적용해야 한다고 판단된다.

위치기반의 드라마 콘텐츠서비스용 스마트 플랫폼 설계 (Smart Platform Design for Location based Drama Contents Services)

  • 최영호
    • 인터넷정보학회논문지
    • /
    • 제18권1호
    • /
    • pp.37-41
    • /
    • 2017
  • 본 논문에서는 PPL(Product Placement)을 변경할 수 있는 위치기반 실시간 비디오 클립을 스트리밍하는 스마트 플랫폼을 제안한다. 제안하는 플랫폼은 LTE 위치인식 기반의 GPS 좌표 값과 비콘 기술을 활용하여 Active Push형태로 사용자에게 촬영지의 드라마 영상을 제공한다. 또한 비디오 클립 내의 PPL 객체에 대한 사진, 동영상, 음악, URI(Uniform Resource Identifier) 형태의 DB를 구성하였다. 제안한 플랫폼에서는 비디오 클립 스트리밍 서비스 상황에서 PPL 객체 DB에 대한 인터액티브 태그 동기화를 통해 PPL 객체의 색깔과 모양을 변경할 수 있도록 하였다. 제안하는 플랫폼에서는 서비스 제공자의 요구에 따라 PPL 변경이 가능한 위치 기반 실시간 비디오 스트리밍을 가능하게 한다.