• Title/Summary/Keyword: Active Method

Search Result 6,294, Processing Time 0.035 seconds

Grid Voltage Estimation Method for Modular Plug-in Active Power Decoupling Circuits (모듈형 플러그인 능동전력디커플링 회로를 위한 계통전압 추종 방법)

  • Kim, Dong-Hee;Kim, Jeong-Tae;Park, Sung-Min;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.294-297
    • /
    • 2021
  • A grid voltage estimation method for modular plug-in active power decoupling (APD) circuits is proposed in this study as direct replacements of electrolytic capacitors. Since modular plug-in APD circuits cannot have additional grid voltage sensors and should be operated independently without information exchange with the front-end converter, it is impossible to obtain the phase information of the grid directly. Therefore, the proposed method uses the second-order harmonic component of the DC-link voltage to estimate the grid voltage necessary to control the APD circuit. By employing the proposed method, the concept of modular plug-in APD circuits can be realized and implemented without direct detection of the grid voltage. The experimental results based on hardware-in-the-loop simulation (HILS) validate the effectiveness of the proposed control method.

Optimal Design of Air-spring and Active Control of Vibration Isolation Table (공기스프링의 최적설계 및 방진 테이블의 능동 제어)

  • An, Chae-Hun;Kim, Ho-Sung;Yim, Kwang-Hyeok;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.909-914
    • /
    • 2006
  • Vibration isolation tables are mostly required in precise measurement and manufacturing system. Among the vibration isolation tables, an air spring is the most favorable equipment because of low resonant frequency and high damping ratio. However, it is difficult to design the air spring with the required stiffness and damping ratio. Futhermore, whenever conventional active control methods are applied to the air spring, it may be difficult to obtain effective control performance due to high nonlinearity of air spring. In this paper, the optimal design of the air spring is performed using genetic algorithm to bring out low resonant frequency and high damping ratio. Also, active control of the vibration isolation table with 3-DOF model is proposed using the adaptive control method. Through experiments, optimal design is shown to be effective. And performance of the proposed control method is verified to be better than those of the passive control method and the conventional active control methods.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

Improvement of MAP Load Balancing in Hierarchical Mobile IPv6 (계층적 Mobile IPv6에서의 MAP 부하 분산 개선에 관한 분석)

  • Song, Bok-Sob;Kim, Jeong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.2
    • /
    • pp.67-75
    • /
    • 2009
  • The growing need for the mobility supportable networks induces the IP-based mobility management protocols. Though HMIPv6 which manages the micro-mobility of mobile nodes using MAPs suggests an effective method for mobility-support for mobile nodes within the domain that is managed by MAP. There is a problem that traffic may be concentrated on MAPs. In this paper, therefore, we proposed a method that can effectively distribute the traffic which is concentrated on a MAP under phased Mobile IPv6. In our proposed method, two or more MAPs are required and classified as an 'Active MAP' or a 'Passive MAP'. In addition, we defined the state of transition events between Active MAP and Passive MAP and the operations among MAPs for load distribution when an overload condition is occurred at some MAPs by traffic congestion. We compared the performance of our proposed method with its phased Mobile IPv6 to prove the propriety of our proposed method. As a result, we showed that our proposed method can provide an enhanced performance by about 12 percentages in view of packet throughput at the node.

The Mirror Active Element Pattern Method for The Radiation Pattern Computation of Linear Array Antennas (선형 배열 안테나의 방사패턴 계산을 위한 Mirror Active Element Pattern 방법)

  • Kim, Jae-Hyun;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.94-102
    • /
    • 2013
  • We propose the mirror active element pattern (AEP) method for the radiation pattern computation of linear array antennas versus scan angles. The computation time for the radiation pattern of linear array antennas using the mirror AEP method is reduced by almost half compared to that using the AEP method because the number of AEPs of elements obtained by the full-wave simulation necessary for the radiation pattern computation of linear array antennas is reduced by almost half. The difference between the radiation patterns of linear array antennas obtained by the full-wave simulation and mirror AEP method is very small for wide scan angle range when the radiation pattern of an antenna element is symmetric.

Circulating Current Control in MMC-HVDC Considering Switching Device Current Capacity under Unbalanced Voltage Conditions (전압 불평형 조건에서 스위칭 소자의 전류용량을 고려한 MMC-HVDC 순환전류 제어기법)

  • Kim, Chun-Sung;Jung, Seung-Hwan;Hwang, Jung-Goo;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.55-65
    • /
    • 2016
  • This paper proposed a new control method which is capable of controlling circulating current considering current capacity of switching device. In the unbalanced voltage conditions, active power and reactive power have double line frequency. Thus, in order to provide active power without ripple, it is necessary to inject the negative sequence current components. However, when the negative current components is injected, it increases the total current flowing in the Arm, and in the Sub-module(SM) the current more than rated is impressed, which leads to destroy the system. Also, in impressing the circulating current reference of each arm, conventional control method impressed applicable $i_{dck}/3$ in the case of balanced voltage conditions. In the case of unbalanced conditions, as arm circulating current of three phase show difference due to the power impressed to each arm, reference of each arm is not identical. In this study, in the case of unbalanced voltage, within permitted current, the control method to decrease the ripple of active power is proposed, through circulating current control and current limitations. This control method has the advantage that calculates the maximum active power possible to generate capacity and impressed the current reference for that much. Also, in impressing circulating current reference, a new control method proposes to impress the reference from calculating active power of each phase. The proposed control method is verified through the simulation results, using the PSCAD/EMTDC.

An active learning method with difficulty learning mechanism for crack detection

  • Shu, Jiangpeng;Li, Jun;Zhang, Jiawei;Zhao, Weijian;Duan, Yuanfeng;Zhang, Zhicheng
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.195-206
    • /
    • 2022
  • Crack detection is essential for inspection of existing structures and crack segmentation based on deep learning is a significant solution. However, datasets are usually one of the key issues. When building a new dataset for deep learning, laborious and time-consuming annotation of a large number of crack images is an obstacle. The aim of this study is to develop an approach that can automatically select a small portion of the most informative crack images from a large pool in order to annotate them, not to label all crack images. An active learning method with difficulty learning mechanism for crack segmentation tasks is proposed. Experiments are carried out on a crack image dataset of a steel box girder, which contains 500 images of 320×320 size for training, 100 for validation, and 190 for testing. In active learning experiments, the 500 images for training are acted as unlabeled image. The acquisition function in our method is compared with traditional acquisition functions, i.e., Query-By-Committee (QBC), Entropy, and Core-set. Further, comparisons are made on four common segmentation networks: U-Net, DeepLabV3, Feature Pyramid Network (FPN), and PSPNet. The results show that when training occurs with 200 (40%) of the most informative crack images that are selected by our method, the four segmentation networks can achieve 92%-95% of the obtained performance when training takes place with 500 (100%) crack images. The acquisition function in our method shows more accurate measurements of informativeness for unlabeled crack images compared to the four traditional acquisition functions at most active learning stages. Our method can select the most informative images for annotation from many unlabeled crack images automatically and accurately. Additionally, the dataset built after selecting 40% of all crack images can support crack segmentation networks that perform more than 92% when all the images are used.

The Study on the Security Model for ActiveX Control Management through Security Authentication (보안 인증을 통한 ActiveX Control 보안 관리 모델에 관한 연구)

  • Park, Sung-Yong;Moon, Jong-Sub
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.6
    • /
    • pp.113-119
    • /
    • 2009
  • In recent years, to provide visitors with the various and dynamic services, many ActiveX Controls are developed and distributed in most of the web sites such as e-Government Internet banking Portal in Korea. However, unsecure ActiveX Controls may be critical security threats on Internet User. Although hacking incidents increase sharply for these vulnerable ActiveX Controls, there are not enough national security actions or policies. Thus, in this paper we propose the technical method to design 'Security model for ActiveX Control Managemnet through Security Authentication' to be able safe and useful security management in three aspects of development distribution using.

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

Design of Active Bandpass Filter Considering The Amplitude Flatness of Passband (대역 내 진폭 특성의 평탄도를 고려한 4단 능동 대역통과 여파기 설계)

  • Bang, Inn-Dae
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.638-648
    • /
    • 2003
  • An active capacitance circuit is analyzed in depth and its application to active RF BPF with low noise figure is discussed. The characteristics of the active capacitance circuit made of FET[1] exhibits negative resistance and conventional capacitance, which is easily controlled. However, it is difficult to make the negative resistance adequate in the designated frequency range due to the lack of detailed analysis, which could make an active circuit unstable as the frequency is going higher or lower. In this paper, we analyzed the negative resistance characteristics of active capacitance circuits and also presented the method that the flatness of passband can be controlled. Finally we have designed a 4-stage active BPE, which results in bandwidth of 100 MHz, 0,04 dB insertion loss, 0.2 dB ripple, and noise figure of 2.4 dB at 1.75 GHz band.

  • PDF