• Title/Summary/Keyword: Active Impedance

검색결과 303건 처리시간 0.027초

Monitoring of Strength Gain in Concrete Using Smart PZT Transducers

  • Qureshi, Adeel Riaz;Shin, Sung-Woo;Yun, Chung-Bang
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.501-508
    • /
    • 2007
  • This paper presents the feasibility of using electromechanical impedance based active sensing technique for nondestructive strength gain monitoring of early-age concrete by employing piezoelectric lead-zirconate-titanate (PZT) patches on concrete surface. The strength development of early age concrete is actively monitored by performing a series of experiments on concrete specimens under moist curing condition. The electrical admittance signatures are acquired for five different curing ages and compared with each other. The resonant frequency shifts of PZT patches with increasing days is observed which is on account of additional stiffening due to strength gain of concrete during curing and level of stiffening being related to strength obtained from compression tests on companion cylinder specimens. The proposed approach is found to be suitable for monitoring the development of compressive strength in early-age concrete. It is also observed in this study that root mean square deviation (RMSD) in admittance signatures of the PZT patches can also be used as an indicator of concrete strength development.

Resonance Investigation and Active Damping Method for VSC-HVDC Transmission Systems under Unbalanced Faults

  • Tang, Xin;Zhan, Ruoshui;Xi, Yanhui;Xu, Xianyong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1467-1476
    • /
    • 2019
  • Grid unbalanced faults can cause core saturation of power transformer and produce lower-order harmonics. These issues increase the electrical stress of power electronic devices and can cause a tripping of an entire HVDC system. In this paper, based on the positive-sequence and negative-sequence impedance model of a VSC-HVDC system as seen from the point of common connection (PCC), the resonance problem is analyzed and the factors determining the resonant frequency are obtained. Furthermore, to suppress over-voltage and over-current during resonance, a novel method using a virtual harmonic resistor is proposed. The virtual harmonic resistor emulates the role of a resistor connected in series with the commutating inductor without influencing the active and reactive power control. Simulation results in PSCAD/EMTDC show that the proposed control strategy can suppress resonant over-voltage and over-current. In addition, it can be seen that the proposed strategy improves the safety of the VSC-HVDC system under unbalanced faults.

식염수에서 내식성 성능에 대한 Al 와이어의 5%Mg 합금 효과 (Effect of 5%Mg alloying in Al wire on corrosion resistance performance in saline solution)

  • 싱 지텐드라 쿠마르;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.93-94
    • /
    • 2022
  • The presence of chloride (Cl-) ions in environments causes localized corrosion resulting decrease the durability of the structures. In this study, 5% Mg containing Al alloys (Al-5Mg) wire used vis-à-vis compared its corrosion resistance with pure Al in 3.5wt.% NaCl solution with exposure periods. Initially both wires exhibited identical open circuit potential (OCP) attributed to the presence of native oxide film on the surface but with the exposure periods it shifted towards active direction owing to the dissolution of oxide film. The pure Al continuously shifted the OCP towards active direction while Al-5Mg shows stabilization of OCP after 8 days of exposure. The OCP of Al-5Mg is slightly higher compared to pure Al wire owing to the activeness of Mg. The total impedance of the Al-5Mg alloy is almost three times greater than pure Al with exposure periods in 3.5 wt.% NaCl solution. It might be formation of Al-Mg LDH (layered double hydroxide) thin film onto the surface.

  • PDF

형상기억합금을 이용한 자가치유 볼트접합부 시스템에 관한 연구 (A Study on Self-Healing Bolted Joints using Shape Memory Alloy)

  • 장하주;이창길;박승희
    • 한국강구조학회 논문집
    • /
    • 제23권5호
    • /
    • pp.629-636
    • /
    • 2011
  • 본 연구는 압전 센서를 이용한 구조물의 실시간 모니터링과 강구조물 볼트접합부의 동적 컨트롤이 가능한 자가치유 시스템에 관한 것이다. 볼트접합부의 볼트 풀림 손상 탐색을 위해서 압전 물질의 전기역학적 커플링 성질을 이용하는 임피던스 기반의 구조물건전성평가 기법을 이용하였다. 계측된 임피던스 값을 기준치 값과 비교함으로써 볼트 풀림 손상 진단이 가능하다. 볼트 풀림 손상은 손상지수를 이용하여 정량적으로 평가되어지고, 손상이 진단되면 형상기억합금 와셔에 감겨있는 외부히터가 와셔에 열을 가하게 된다. 열이 가해진 형상기억합금 와셔는 축방향으로 팽창하고, 볼트접합부는 볼트풀림으로 인해 잃어버린 토크력을 회복하게 된다. 압전 센서를 이용한 임피던스 기반의 구조물건전성 평가기법과 형상기억합금 기반의 볼트접합부 동적 컨트롤 기능과 이를 이용한 자가치유 볼트접합부 시스템의 적용가능성과 성능을 실험을 통해 평가하였다.

시간영역에서 순시 유효/무효전력을 이용한 마이크로그리드의 단독운전 판단 (Islanding Detection for a Micro-Grid based on the Instantaneous Active and Reactive Powers in the Time Domain)

  • 이영귀;김연희;정태영;김태현;강용철
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.22-27
    • /
    • 2012
  • Correct and fast detection of a micro-grid (MG) islanding is essential to the MG since operation, control and protection of the MG depend on an operating mode i.e., an interconnected mode or an islanding mode. When islanding occurs, the frequency of the point of common coupling (PCC) is not the nominal frequency during the transient state owing to the frequency rise or drop of generators in the MG. Thus, the active and reactive power calculated by the frequency domain based method such as Fourier Transform might contain some errors. This paper proposes an islanding detection algorithm for the MG based on the instantaneous active and reactive powers delivered to the dedicated line in the time domain. During the islanding mode, the instantaneous active and reactive powers delivered to the dedicated line are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. In this paper, the instantaneous active and reactive powers are calculated in the time domain and used to detect islanding. The performance of the proposed algorithm is verified under various scenarios including islanding conditions, fault conditions and load variation using the PSCAD/EMTDC simulator. The results indicate that the algorithm successfully detects islanding for the MG.

A low cost miniature PZT amplifier for wireless active structural health monitoring

  • Olmi, Claudio;Song, Gangbing;Shieh, Leang-San;Mo, Yi-Lung
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.365-378
    • /
    • 2011
  • Piezo-based active structural health monitoring (SHM) requires amplifiers specifically designed for capacitive loads. Moreover, with the increase in number of applications of wireless SHM systems, energy efficiency and cost reduction for this type of amplifiers is becoming a requirement. General lab grade amplifiers are big and costly, and not built for outdoor environments. Although some piezoceramic power amplifiers are available in the market, none of them are specifically targeting the wireless constraints and low power requirements. In this paper, a piezoceramic transducer amplifier for wireless active SHM systems has been designed. Power requirements are met by two digital On/Off switches that set the amplifier in a standby state when not in use. It provides a stable ${\pm}180$ Volts output with a bandwidth of 7k Hz using a single 12 V battery. Additionally, both voltage and current outputs are provided for feedback control, impedance check, or actuator damage verification. Vibration control tests of an aluminum beam were conducted in the University of Houston lab, while wireless active SHM tests of a wind turbine blade were performed in the Harbin Institute of Technology wind tunnel. The results showed that the developed amplifier provided equivalent results to commercial solutions in suppressing structural vibrations, and that it allows researchers to perform active wireless SHM on moving objects with no power wires from the grid.

케이블 구동 메커니즘을 이용한 재활 로봇의 능동 컴플라이언스 제어 (Active Compliance Control for the Rehabilitation Robot with Cable Driven Transmission)

  • 강상훈;장평훈;박형순
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1823-1832
    • /
    • 2004
  • In this paper, we proposed a TDC based F/T sensorless active compliance control algorithm for a rehabilitation robot (KARES II). The preference of compliance of the disabled is presented by clinical testing at Korea National Rehabilitation Center with the disabled. The KARES II was designed to work 12 predefined tasks which are very essential for helping the disabled. Among the tasks, some contact tasks between the robot and the disabled exist. Therefore, TDC based F/T sensorless compliance control algorithm is developed for these tasks without additional cost. We verified the proposed algorithm with experiment. Also for the practical use, suitable compliance for contact tasks is chosen by clinical testing at Korea National Rehabilitation Center.

Active Microstrip Antenna for Mobile Communication

  • Nakasuwan, J.;Rakluea, P.;Songthanapituk, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.28-31
    • /
    • 2004
  • This paper describe analysis active microstrip antenna with low noise amplifier at 900 MHz for mobile communication. The microstrip patch antenna is integrated with low noise amplifier on a permittivity 4.5 (Epoxy-FR4) and thickness of substrate 1.6 mm. Low noise amplifier is designed by using GaAs FETs. The analysis characteristics of antenna include return loss, input impedance, vswr, radiation pattarn, bandwidth and gain of antenna. Mesurement gain of antenna is shown 19.2435 dBi.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

The Design on a Wideband Active Printed Dipole Antenna using a Balanced Amplifier

  • Lee, Sung-Ho;Kwon, Se-Woong;Lee, Byoung-Moo;Yoon, Young-Joong;Song, Woo-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제2권2호
    • /
    • pp.112-116
    • /
    • 2002
  • In this paper, the active integrated antenna(AIA) using a wideband printed dipole antenna and a balanced amplifier is designed and fabricated. The proposed active printed dipole antenna has characteristics of easy matching, wide bandwidth and higher output power To feed balanced signal to printed dipole, a Wilkinson power divider and delay lines are used. The measured result shows that, at 6 GHz center frequency, the impedance bandwidth is 22 % (VSWR < 2), 3 dB gain bandwidth is 28 %, the maximum gain is 14.77 dBi, and output power at P1 dB point is 23 dBm.