• 제목/요약/키워드: Activated sludge process

검색결과 415건 처리시간 0.026초

활성슬러지공정에서 구리의 거동에 관한 연구 (A Study on the Cu2+ Behavior in Activated Sludge Process)

  • 박진도;이학성
    • 한국환경과학회지
    • /
    • 제19권9호
    • /
    • pp.1119-1127
    • /
    • 2010
  • The behavior of copper throughout the whole process of wastewater treatment plant that uses the activated sludge process to treat the wastewater of petrochemical industry that contains low concentration of copper was investigated. Total inflow rate of wastewater that flows into the aeration tank was $697\;m^3$/day with 0.369 mg/L of copper concentration, that is, total copper influx was 257.2 g/day. The ranges of copper concentrations of the influent to the aeration tank and effluent from the one were 0.315 ~ 0.398 mg/L and 0.159 ~ 0.192 mg/L, respectively. The average removal rate of copper in the aeration tank was 50.8 %. The bioconcentration factor (BCF) of copper by microbes in the aeration tank was 3,320. The accumulated removal rate of copper throughout the activated sludge process was 71.3%, showing a high removal ratio by physical and chemical reactions in addition to biosorption by microbes. The concentration of copper in the solid dehydrated by filter press ranged from 74.8 mg/kg to 77.2 mg/kg and the concentration of copper by elution test of waste was 2.690 ~ 2.920 mg/L. It was judged that the copper concentration in dehydrated solid by bioconcentration could be managed with the control of that in the influent.

활성슬러지 공정에 의한 Acetaldehyde 제조 공장 폐수의 처리 (Treatment of Wastewater from Acetaldehyde Plant by Activated Sludge Process)

  • 서승교;김정호;김영호
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.259-265
    • /
    • 1997
  • This study was conducted to Investigate the treatment of wastewater from acetaldehyde manufacturing plant by activated sludge process with Micrococcus roseus AW-6, Micrococcus roseus AW-22, Microbacterium lacticum AW-38 and Mlcrobacterium nae- vaniformans AW-41. The $COD_{Mn}$ and $BOD_5$ of the wastewater were 5, 260mg/L and 6, 452mg/L, respectively. pH was 1.85. The main organic component in the wastewater was acetic acrid which was contained 67, 600mg/L. Optimum dilution time for activated sludge process was shown 10 times. The specific substrate removal rate(BL) was 1.95day-1 and the nonbiodegradable matters(Sn) were 23.2mg/L. Saturation constant (Ks) and mainmum specific growth rate(qmax) were 1, 640mg/L and 2.33day-1, respectively. Sludge yield coefficient(Y) and endogenous respiration coefficient(kd) were 0.28mg MLVSS/mgCOD and 0.02day-1, respectively. $COD_{cr}$ removal efficiency was 91% for 1.95day of hydraulic retention time.

  • PDF

미세 기포에 의한 활성슬러지의 부상특성 (Flotation Characteristics of Activated Sludge by Micro-bubbles)

  • 김성진;강병준;박상욱;이재욱;정흥조;곽동희
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.501-507
    • /
    • 2006
  • Dissolved air flotation (DAF) has been well known for the gravity separation process. The solids to be separated are transferred from the water body to the water surface using micro-air bubbles. DAF has also been used for enhancing solids-liquid separation of industrial and municipal wastewater by adding a its unit parallel to a sedimentation unit to reduce the hydraulic loading in the sedimentation clarifier. This study was to investigate flotation characteristics of activated sludge by the recent DAF technique without chemical agents. In addition, the effect on temperature in flotation of activated sludge and the thickening degree of activated sludge were studied.

하수처리 활성오니공정을 위한 규칙 베이스 퍼지 제어기 설계 (Design of Rule-Based Fuzzy Controller for Activated Sludge Process in Sewage Water Treatment)

  • 황희수;김현기;오성권;우광방
    • 전자공학회논문지B
    • /
    • 제28B권7호
    • /
    • pp.557-565
    • /
    • 1991
  • The activated sludge process is a commonly used method for terating sewage and waste waters. The process is chatacterized by a lack of measurement instrumentations and control goals that are not always clear and not well understood. In such process, fuzzy control concept may be able to be adapted, do this paper presents a design method for fuzzy controller based on a selected sub-rule set from the total rule set and a multivariable fuzzy reasoning algorithms. In order to achievesystematic and efficient control of the activated sludge process under a great deal of disiutbances and a variety of perfotmance characteristics, a top-level rule-based fuzzy controller os proposed which provises lower-controllers with the suitable set-points according tothe onput-output states of the process.

  • PDF

공기부상법을 이용한 활성슬러지의 부상분리 특성 (Thickening Characteristics of Activated Sludge by Air Flotation Process)

  • 박찬혁;홍석원;맹주원;이상협;최용수;문성용
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.747-753
    • /
    • 2006
  • Air flotation is a solid-liquid separation process that utilizes up-flow microbubbles to thicken activated sludge and enhance clarification efficiency. Continuous air flotation experiments were performed to investigate the effect of operation parameters such as initial MLSS (mixed liquor suspended solid) concentration, air pressure, surface loading rate, air to solid (A/S) ratio, and flotation time on thickening efficiency. An initial activated sludge concentration ranged from 3,000 to 12,000mgSS/L and thickened sludge concentration varied from 6,400 to 28,100mgSS/L. The result showed that the thickening efficiency was mainly dependent on surface loading rate, A/S ratio, and flotation time. The pressure did not affect the thickening efficiency when it kept in the range of 1.6 to 1.8 bar. Experimental results showed that the thickening efficiency of activated sludge was increased only when the feed sludge concentration exceeded 5,000mgSS/L and the thickened concentration was over 20,000mgSS/L. At this time, SS concentration in the clarified liquid was ranged from 5 to 10mg/L.

하수처리 활성오니공정의 에너지 절감을 위한 퍼지 제어 방법에 관한 연구 (A Study on Fuzzy Control Method of Energy Saving for Activated Sludge Process in Sewage Treatment Plant)

  • 남의석
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1477-1485
    • /
    • 2018
  • There are two major issues for activated sludge process in sewage treatment plant. One is how to make sewage be more clean and the other is the energy saving in sewage treatment process. The major monitoring sewage qualities are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent. These are transmitted to the national TMS(Telemetry Monitoring System) at every hour. If these exceed the environmental standard, the environmental charges imposed. So, these water qualities are to be controlled below the environmental standard in operation of sewage treatment plant. And recently, the energy saving is also important in process operation. Over 50% energy is consumed in blowers and motors for injection oxygen into aeration tank. So, with the water qualities to be controlled below the environmental standard, the energy saving also is to be accomplished for efficient plant management. Almost researches are aimed to control water quality without considering energy saving. AI techniques have been used for control water quality. AI modeling simulator provided the optimal control inputs(blower speed, waste sludge, return sludge) for control water quality. Blower speed is the main control input for activated sludge process. To make sewage be more clean, the excessive blower speed is supplied, but water quality is not better than the previous. In results, non necessary energy is consumed. In this paper we propose a new method that the energy saving also is to be accomplished with the water qualities to be controlled below the environmental standard for efficient plant management. Water qualities in only aeration tank are used the inputs of fuzzy models. Outputs of these models are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent and have the environmental standards. In test, we found this method could save 10% energy than the previous methods.

하수처리 프로세스의 선형 추론 퍼지 모델링 (Fuzzy Modeling of Activated Sludge Process Using Linear Reasoning Method)

  • 오성권;박종진;이성주;황희수;김현기;우광방
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.417-420
    • /
    • 1990
  • The conventional quantitative techniques of system analysis are intrinsically unsuited for dealing with humanistic systems. Therefore, the rule based modeling of fuzzy linguistic type has been developed for the analysis of humanistic systems and complex systems and it is very significant for analysis and design of fuzzy logic controller. The activated sludge process is a commonly used method for treating sewage and waste waters. A mathematical tool to build a fuzzy model of the activated sludge process where fuzzy implications and linear reasoning are used is presented in here. A root-mean square error is used as the criterion of the fuzzy model's adequacy to the A.S.P. and the least square method is used for the identification of optimum consequence parameters. A method of modeling of the activated sludge process using its input-output data and simulation results for its application are shown.

  • PDF

The Processing of Livestock Waste Through the Use of Activated Sludge - Treatment with Intermittent Aeration Process -

  • Osada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권5호
    • /
    • pp.698-701
    • /
    • 2000
  • To prevent surface and underground water pollution, wastewater treatment is essential. Four bench-scale activated sludge units (10 L operational volumes) were operated at 5, 10 and $20^{\circ}C$ for evaluation of treatment efficiencies with typical wastewater from swine housing. The units were set for a 24-hour cycle. As compared to the conventional process, high removal efficiencies for organic substances, nitrogen and phosphorus in swine wastewater were obtained simultaneously with an intermittent aeration process (lAP). The NOx-N produced during an aeration period was immediately reduced to nitrogen gas (e.g. $N_2$ or $N_2O$) in the subsequent non-aeration periods, and nitrification in aeration periods occurred smoothly. Under these conditions, phosphorus removal occurred with the release of phosphorus during the non-aeration periods followed by the excess uptake of phosphorus in the activated sludge during aeration periods. It was confirmed that the lAP had a better ability to remove pollutants under both low temperatures and high nitrogen loading conditions than the ordinary method did. In addition to that, the total emission of $N_2O$ from lAP was reduced to approximately 1/50 of the conventional process for the same loading. By adopting an adequate aeration programme for individual swine wastewater treatment, this system will provide a promising means for nitrogen and phosphorus control without pH control or addition of methanol.

Ejector형 포기장치를 이용한 식품가공폐수를 처리 (Food Processing Wastewater Treatment with Ejector-Type Aerator)

  • 정용현
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.221-225
    • /
    • 1999
  • This study was conducted to evaluate the treatment efficiency including reaction kinetics and hydraulic characteristics of food processing wastewater by using an ejector-type aeration system (ETAS) in activated sludge process. The oxygen transfer efficiency in ETAS can be changed in accordance with the depth of reactor. However, the optimum air velocity was found less than 1.82 m/hr at a superficial liquid velocity of 634 m/hr. The ETAS process showed higher organic material removal efficiency than that of the existing activated sludge process under hydraulic detention time 6 to 12 hours. This process, which can maintain MLVSS highly, is able to have high organic material removal efficiency at short HRT and deal with variable organic material loading.

  • PDF

대사열의 발생을 이용한 활성슬러지의 활성 측정

  • 박순응;허원
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.398-401
    • /
    • 2000
  • A device to measure the temperature difference between the supernatant and the sediment blanket in the course of SV30 measurement in processing of activated sludge process. The temperature elevation in the sludge sediment represent the metabolic heat production by the microorganisms and can be an indicator for the capability of waste treatment. The utilities of the device for the analysis of activated sludge process were demonstrated in this report.

  • PDF