• Title/Summary/Keyword: Activated carbon adsorption

Search Result 961, Processing Time 0.028 seconds

Adsorption and Thermal Regeneration of Toluene and Benzene on the Fixed Bed Packed with Activated Carbon and Activated Carbon Fiber

  • Kim, Jong-Hwa;Oh, Ok-Kyun;Haam, Seung-Joo;Lee, Chang-Ha;Kim, Woo-Sik
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.44-54
    • /
    • 2001
  • The characteristics of adsorption and desorption of benzene and toluene were investigated at a fixed bed packed with the activated carbon and activated carbon fiber. Through breakthrough experiments under various feed concentration conditions, it was found that the slope of mass transfer zone and the tailing in the breakthrough curves were different from the feed conditions due to different heats of adsorption. In hot nitrogen desorption, the regeneration time and mass transfer zone of the toluene desorption curve were longer than those of the benzene desorption curve because of the difference in adsorption affinity. With an increase in the regeneration temperature, the height of roll-up and the sharpness of desorption curves increased but the regeneration times decreased. The adsorption capacities of the activated carbon and activated carbon fiber after three-time thermal regenerations decreased about 25% and 37% for benzene and 18% and 25% for toluene, respectively. To investigate the effect of the regeneration temperature on the energetic efficiency, the characteristic desorption temperatures of toluene and benzene were investigated by calculating purge gas consumption and temperature.

  • PDF

Physical and Chemical Adsorption Properties for Tetracycline Using Activated Carbon with Nitrogen Plasma Treatment (질소 플라즈마 처리된 활성탄소를 이용한 테트라사이클린의 물리 및 화학 흡착 특성)

  • In Woo Lee;Seongjae Myeong;Chung Gi Min;Seongmin Ha;Seoyeong Cheon;Young-Seak Lee
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.8-15
    • /
    • 2024
  • In this study, nitrogen plasma treatment was performed in 5, 10, and 15 minutes to improve the tetracycline adsorption performance of activated carbon. All nitrogen plasma-treated activated carbons showed improved tetracycline adsorption compared to untreated activated carbons. The nitrogen functional groups in activated carbon lead to chemisorption with tetracycline via π-π interactions and hydrogen bonding. In particular, in the nitrogen plasma treatment at 80 W and 50 kHz, the activated carbon treated for 10 minutes had the best adsorption performance. At this time, the nitrogen content on the surface of the activated carbon was 2.03% and the specific surface area increased to 1,483 m2/g. As a result, nitrogen plasma treatment of activated carbon improved its physical and chemical adsorption capabilities. In addition, since the adsorption experimental results were in good agreement with the Langmuir isotherm and pseudo-second order model, it was determined that the adsorption of tetracycline on the nitrogen plasma-treated activated carbon was dominated by chemical adsorption through a monolayer. As a result, nitrogen plasma-treated activated carbon can be used as an adsorbent to efficiently remove tetracycline from water due to the synergistic effect of physical adsorption and proactive chemical adsorption.

Vapor Phase Mercury Removal by Sulfur Impregnated Activated Carbons and Sulfur Impregnation Protocol

  • Lee, Si-Hyun;Cha, Sun-Young;Park, Yeong-Seong
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 2001
  • Mercury has been identified as a potential health and environmental hazardous material. Activated carbon adsorption offers promising potential for the control of mercury emissions, and sulfur impregnated (sulfurized) activated carbons has been shown to be an effective sorbent for the removal of vapor phase $Hg{\circ}$ from sources. In this work, vapor phase mercury adsorption by sulfur impregnated activated carbons were investigated. Sulfur impregnated activated carbons were made by variation of impregnation temperature, and the comparison of adsorption characteristics with commercial virgin and sulfurized carbons were made. Factors affecting the adsorption capacity of virgin and sulfurized activated carbons such as pore characteristics, functional groups and sulfur impregnation conditions were discussed. It was found that the sulfur allotropes plays a critical role in adsorption of mercury vapor by sulfurized activated carbons.

  • PDF

Removal Efficiency of Toxic Heavy Metal Ions in Wastewater by Double Surface-Modified Activated Carbon

  • Park, Geun-Il;Kim, In-Tae;Song, Kee-Chan;Kim, Kwang-Wook;Kim, Joon-Hyung;Yoo, Jae-Hyung
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.307-312
    • /
    • 2001
  • Adsorption capacities of toxic heavy metal ions using as-received carbon(AC), single and double surface-modified activated carbon(OAC and DSMC) in wide pH ranges are extensively evaluated. Physical and chemical properties of surface-modified activated carbons are evaluated through BET analysis, surface acidity and oxides measurements. Based oil tile adsorption isotherms of Pb, Cd and Cr ions by AC, OAC and DSMC, the adsorption amount on DSMC was obviously higher than that on the other carbons. Breakthrough behaviors of ternary metal ions in a column packed with three kinds of carbon were also characterized with respect to the variations of the influent pH and concentration. The adsorption capacity of DSMC in a fixed bed stood a favorable comparison with that of as-received carbon.

  • PDF

The Preparation of PAN-based Activated Carbon Fiber by KOH (KOH 활성화에 의한 PAN계 활성탄소섬유의 제조)

  • 김기원;정승훈;임연수;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.6
    • /
    • pp.577-582
    • /
    • 1999
  • Activated carbon fibers were prepared from stabilized PAN fibers by chemical activation using hydroxide. The variations in specific surface area amount of iodine adsorption micro-structure and pore size distribution in the activated carbon fibers after the activation process were discussed. In the chemical activation using potassium hydroxide specific surface area of about 2545m2/g and amount of iodine adsorption of 2049 mg/g were obtained at the condition of KOH/fiber ratio of 1 and 800$^{\circ}C$ Nitrogen adsorption isotherms for PAN based activated carbon fibers showed the type I in the Brunauer-Deming-Deming-Teller classification indicating the micro-pores consisting the activated fibers.

  • PDF

Effect of vacuum regeneration of activated carbon on volatile organic compound adsorption

  • Pak, Seo-Hyun;Jeon, Yong-Woo
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.169-174
    • /
    • 2017
  • Vacuum swing adsorption (VSA) is a promising treatment method for volatile organic compounds (VOCs). This study focuses on a VSA process for regenerating activated carbon spent with VOCs, and then investigates its adsorption capacities. Toluene was selected as the test VOC molecule, and the VSA regeneration experiments results were compared to the thermal swing adsorption process. Cyclic adsorption-desorption experiments were performed using a lab-scale apparatus with commercial activated carbon (Samchully Co.). The VSA regeneration was performed in air (0.5 L/min) at 363.15 K and 13,332 Pa. The comparative results depicted that in terms of VSA regeneration, it was found that after the fifth regeneration, about a 90% regeneration ratio was maintained. These experiments thus confirm that the VSA regeneration process has good recovery while operating at low temperatures (363.15 K) and 13,332 Pa.

Flow Characteristics and Residence Time of Activated Carbon in the Cyclone for Optimized Design of an Adsorption/Catalysis Reactor (흡착/촉매 공정개선을 위한 사이클론 내 유동특성 및 활성탄 체류시간 산정)

  • Choi, Choeng-Ryul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.416-424
    • /
    • 2007
  • In adsorption/catalytic process, numerical analysis has been performed to identify the flow characteristics of flue gas in the cyclone and to estimate the residence time of activated carbon using Computational Fluid Dynamics (CFD) technique. To consider flue gas and activated carbon particles simultaneously, Euler-Lagrangian model was employed so that residence time could be obtained from the numerical analysis directly. The numerical analysis has been performed with different three particle sizes and compared each flow characteristics with particle’ size. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution, residence time of flue gas, and activated carbon particles and distribution of activated carbon have been obtained from the numerical analysis.

Adsoption Removal of PCBs by Activated Carbon (활성탄에 의한 PCBs의 흡착제거)

  • Yu, Yong-Ho;Lee, Jong-Jig
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.59-64
    • /
    • 2006
  • In this study, adsorption characteristics of PCBs on granular activated carbon were experimentally investigated in a batch reactor and in a fixed bed reactor. Granular activated carbon removed above 98.4% of initial concentration, 1000mg/L, of PCBs. It was estabilished that the adsorption equilibrium of PCBs on granular activated carbon was more successfully fitted by Freundlich isotherm equation in the concentration range from 1 to 1000mg/L. Because Freundlich parameter, ${\beta}$ is 0.346, removall treatment of PCBs by activated carbon accounts for the fact that toxicity reduction can be achieved through this process. Appearance time of breakthrough curve is faster with the increase flow rate and inflow concentration of liquid. The utility of granular activated carbon is enhanced with the increase of bed height and with the decrease of inflow rate.

Adsorption of p-Nitrophenol by Surface Modified Carbons from Aqueous Solution

  • Goyal, Meenakshi
    • Carbon letters
    • /
    • v.5 no.2
    • /
    • pp.55-61
    • /
    • 2004
  • Adsorption isotherms of p-nitrophenol from its aqueous solutions on two samples of activated carbon fibres and two samples of granulated activated carbons have been determined in the concentration range 40~800 mg/L (ppm). The surface of these carbons was modified by oxidation with nitric acid and oxygen gas, and by degassing the carbon surface under vacuum at temperatures of $400^{\circ}C$, $650^{\circ}C$ and $950^{\circ}C$. The oxidation of carbon enhances the amount of carbon-oxygen surface groups, while degassing decreases the amount of these surface groups. The adsorption of p-nitrophenol does not depend upon the surface area alone but appears to be influenced by the presence of oxygen groups on the carbon surface. The adsorption decreases on oxidation while the degassing of the carbon surface enhances the adsorption. The decrease in adsorption depends upon the strength of the oxidative treatment being much larger in case of the oxidation with nitric acid, while the decrease in adsorption on degassing depends upon the temperature of degassing. The results show that while the presence of acidic surface groups which are evolved as $CO_2$ on degassing suppress the adsorption of p-nitrophenol, the presence of non acidic surface groups which are evolved as CO on degassing tend to enhance the adsorption. Suitable mechanisms compatible with the results have been presented.

  • PDF

Adsorptive Removal of Acid Green 20 from Aqueous Solutions by Biomass Ash and Activated Carbon

  • Purai, Abhiti;Rattan, V.K.
    • Carbon letters
    • /
    • v.10 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • Study on the removal of Acid Green 20 by adsorption on indigenously prepared activated carbons from cow dung, mango stone, parthenium leaves and commercial activated carbon have been carried out with an aim to obtain information on treating effluents from tanneries. The effects of various experimental parameters have been investigated by following the batch adsorption technique. Adsorption data was modeled with the Freundlich and Langmuir isotherms. Removal of Acid Green 20 was found to be favorable using Biomass ash and could be considered as alternatives to commercial activated carbon for the treatment of tannery effluents, especially for the removal of dye(s).