• Title/Summary/Keyword: Activated Sludge

Search Result 789, Processing Time 0.05 seconds

광합성세균 미생물막반응기에 의한 유기성폐수의 처리특성

  • Oh, Kwang-Keun;Lee, Cheol-Woo;Jeon, Yeong-Joong;Lee, Jae-Heung
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.6
    • /
    • pp.738-742
    • /
    • 1996
  • An efficient packed-bed type biofilm reactor charged with immobilized phototrophs was developed to treat organic wastewater at an extremely high volumetric loading rate. The packed bed reactor (PBR) charged with porous ceramic beads was superior to a fluidized-bed reactor suspended with activated carbon powders in terms of many aspects such as BOD removal efficiency, operational stability, and overall economics. For wastewater with BOD concentration as high as 20, 000mg/l, the BOD removal efficiency was maintained above 90% when the hydraulic retention time (HRT) was longer than 1 day. The allowable volumetric BOD loading rate of this reactor (20gBOD/l day) is more than ten-folds higher than that of an ordinary activated sludge method. The behaviour of the reactor was represented well by a Monod type kinetic equation with a maximum specific BOD loading rate(P) of 22.2gBOD/l day and a half saturation constant(K$_{s}$) of 1, 750 mgBOD/l.

  • PDF

Pore Structure and Adsorption Characteristics of Metals and Nutrient Salt of Activated Carbon Produced from Different Chemical Treatment (서로 다른 약품처리를 이용하여 제조한 활성탄의 세공구조 및 중금속과 영양염류 흡착특성)

  • Lee, Young-Dong;Kang, Hwa-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1319-1330
    • /
    • 2000
  • Activated carbons prepared by chemical activation of organic waste sludges with $ZnCl_2$ and $K_2S$ have been studied in terms of their pore development and adsorptivity. Pore development of the carbons prepared from organic waste sludges was characterized by the nitrogen adsorption at 77K. The $ZnCl_2$-activated carbon produced by chemical activation with zinc chloride exhibited type I isotherm characteristics according to the BDDT classification, suggesting the presence of micropores formed by activation process. The isotherms of the commercial powdered activated carbon and $K_2S$-activated carbon reveal a hysteresis similar to that of type IV in BDDT classification, indicating the formation of mesopores. This result implies that the major pores of $K_2S$-activated carbon are composed of meso and micropores, and a macropores are minor. The adsorptive capacities of metal on the $K_2S$-activated carbon prepared from organic waste sludges were found to be superior to those on a commercial granular activated carbon. The Langmuir and Freundlich isotherms yield a fairly good fit to the adsorption data, indicating a monolayer adsorption of metals onto $K_2S$-activated carbon. The adsorptive capacity of the $K_2S$-activated carbon was superior to $ZnCl_2$-activated carbon for $PO_4$-P, and vice versa for $NO_3$-N. From the results of the studies reported here, it can be concluded that activated carbons with adsorptivity superior to commercial granular activated carbons can be produced from organic waste sludge using a two-step carbonization/activation procedure with zinc chloride or potassium sulfide as the activating agents.

  • PDF

Effective correlation between coagulation efficiency and the sludge settling characteristic (슬러지 응집효율이 침강특성에 미치는 상관관계에 대한 연구)

  • Han, Gee-Bong;Yoon, Ji-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.151-159
    • /
    • 2006
  • In these days, the importance of sludge treatment is emerging due to the London Convention, so this study was conducted to propose the alternatives for the improved sludge treatment on the organic wastewater and sewage sludge with JAR test and settling column equipped with stirrer. The minimum coagulant dosage to earn the optimum sludge settling efficiency resulted from 200mg/l and each critical sludge settling interface showed no distinct difference when PAC was dosed over 200mg/l. Accordingly, Clarification Rate(CR) with 200mg/l dosage was calculated to CR=(Ho-Ht) / Ho=1-0.4=0.6 because the critical sludge settling height stopped at 0.4. The settling velocity of sludge interface was decreased with the increase of MLSS concentration but rather increased with MLSS concentration over 1,000mg/l. This resulted from positive effect of interacted coagulation for floc formation by transfer to the zone of compressed settling when MLSS concentration increased over 1,000mg/l. The settling velocity of sludge interface showed $28.66{\times}10^{-3}/min$ for average settling velocity of sewage sludge which is 6.7 times higher than $4.25{\times}10^{-3}/min$ for average settling velocity of organic wastewater sludge. The increasing rate of CR for organic wastewater activated sludge was higher than that of settling velocity under 200mg/l of PAC dosage but settling velocity was higher than CR over 200mg/l of PAC dosage. However, in case of sewage sludge, the differential rate of CR was low when PAC dosage was increased but the settling velocity was suddenly increased with over 200mg/l dosage. Therefore coagulation effect was more efficient to MLSS settling velocity rather than SS removal effect in the supernatant.

  • PDF

High-Rate Nitrogen Removal using a Submerged Module of Sulfur-Utilizing Denitrification (침지형 황 탈질 모듈을 이용한 고속의 질소제거)

  • Moon, Jin-Young;Hwang, Yong-Woo;Ga, Mi-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.429-437
    • /
    • 2007
  • This study aims to develop a sulfur-using denitrification process which is possible a renovation to advanced treatment plant submerging a simple module in activated sludge aeration tank. At first, the impact factor of sulfur-using denitrification was appreciated by the batch test. Secondly, reflecting a dissolved oxygen effect of sulfur-using denitrification that was confirmed by the batch test, in a continuous nitrification/sulfur-using denitrification, high-rate nitrogen removal reaction was induced at optimum condition controlling DO concentration according to phases. Also, inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. Result of batch test for sulfur-using denitrification, $NO_2{^-}N$ was lower for consumption of alkalinity and sulfur than that of $NO_3{^-}-N$. These results revealed the accordance of theoretical prediction. In continuous nitrification/sulfur-using denitrification experiment, actual wastewater was used as a influent, and influent nitrogen loading rates were increased 0.04, 0.07, 0.11, $0.14kg\;N/m^3-day$ by changing hydraulic retention times. At this time, nitrogen loading rates of packed sulfur were increased 0.23, 0.46, 0.69, $0.93kg\;N/m^3-day$. As a result, nitrification efficiency was about 100% and denitrification efficiency was 93, 81, 79, 72%. Accordingly, nitrogen removal was a high-rate. Also the module of sulfur-using denitrification covered with microfilter did not make a fouling phenomena according to increased flux. And the module was achieved effluent suspended solids of below 10 mg/L without a clarifier. In conclusion, it is possible a renovation to advanced treatment plant submerging a simple module packed sulfur in activated sludge aeration tank of traditional facilities. And the plant used the module packed sulfur is expected as a effective facilities of high-rate and the smallest.

Design of Modeling & Simulator for ASP Realized with the Aid of Polynomiai Radial Basis Function Neural Networks (다항식 방사형기저함수 신경회로망을 이용한 ASP 모델링 및 시뮬레이터 설계)

  • Kim, Hyun-Ki;Lee, Seung-Joo;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.554-561
    • /
    • 2013
  • In this paper, we introduce a modeling and a process simulator developed with the aid of pRBFNNs for activated sludge process in the sewage treatment system. Activated sludge process(ASP) of sewage treatment system facilities is a process that handles biological treatment reaction and is a very complex system with non-linear characteristics. In this paper, we carry out modeling by using essential ASP factors such as water effluent quality, the manipulated value of various pumps, and water inflow quality, and so on. Intelligent algorithms used for constructing process simulator are developed by considering multi-output polynomial radial basis function Neural Networks(pRBFNNs) as well as Fuzzy C-Means clustering and Particle Swarm Optimization. Here, the apexes of the antecedent gaussian functions of fuzzy rules are decided by C-means clustering algorithm and the apexes of the consequent part of fuzzy rules are learned by using back-propagation based on gradient decent method. Also, the parameters related to the fuzzy model are optimized by means of particle swarm optimization. The coefficients of the consequent polynomial of fuzzy rules and performance index are considered by the Least Square Estimation and Mean Squared Error. The descriptions of developed process simulator architecture and ensuing operation method are handled.

Determination of Oxygen Transfer Characteristics (α, β and R) in an Aeration Basin at a Conventional Activated Sludge Wastewater Treatment Plant (활성슬러지 하수처리장 포기조내 산소 전달특성(α, β와 R)의 효율적 산정방안 개발)

  • Ko, Kwang Baik;Choi, Mee Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.989-997
    • /
    • 1994
  • The major objective of this study is to develop an effective method to estimate ${\alpha}$ and ${\beta}$ in an aeration basin at a conventional activated sludge wastewater treatment plant. A series of unsteady state batch tests were simultaneously performed with clean water and mixed liquor in two batch reactors under identical operational conditions. Oxygen uptake rates (OURs) of the mixed liquor were measured during the tests. The results show that the OURs due to synthesis respiration and endogenous respiration were averaged about $17.96 mg/(l{\cdot}hr)$ and about $12.29mg/(l{\cdot}hr)$, respectively. The corresponding ${\alpha}$ and ${\beta}$ were ranged between 0.65 to 0.95, and between 0.88 to 0.93, respectively. Based on the overall experimental results, the proposed experimental test method and the proposed method for determination of ${\alpha}$ and ${\beta}$ are found to be relatively simple and easy to use in evaluating the characteristics of aeration systems.

  • PDF

Evaluation of the COD Fractionation Capability Using Storage Microorganism from EBPR Process (EBPR 공정내 저장 미생물을 이용한 유입수 분율 분석능 평가)

  • Kim, Youn-Kwon;Seo, In-Seok;Kim, Hong-Suck;Kim, Ji-Yeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.25-31
    • /
    • 2004
  • In conventional activated sludge process, COD fractions in wastewater are important parameters, significantly. Depending on characteristics of influent COD fractionation, activated sludge process requires a major change of a process operation to ensure meeting a stricter standards. In order to validate and evaluate the accuracy of the traditional COD fractionation methodologies, readily and slowly biodegradable COD was mixed using glucose and peptone as a sole carbon source in a synthetic wastewater, respectively. In this research, prediction of the COD fraction was made using the OUR(Oxygen Utilization Rate) and the NUR(Nitrate Utilization Rate) experiments. The result showed that COD fractions calculated by OUR experiment were similar to the composition of synthetic wastewater. On the other hand, it was found that an error was generated during the NUR experiment. This error was due to the intracellular storage period for storage microorganisms such as PAOs, and the error in COD fraction was observed about 8-14 % in terms of Total COD.

  • PDF

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.