• Title/Summary/Keyword: Acrylic material

Search Result 340, Processing Time 0.022 seconds

Effect of Cross-Linking Characteristic on the Physical Properties and Storage Stability of Acrylic Rubber

  • Seong-Guk Bae;Min-Jun Gim;Woong Kim;Min-Keun Oh;Ju-Ho Yun;Jung-Soo Kim
    • Elastomers and Composites
    • /
    • v.58 no.3
    • /
    • pp.136-141
    • /
    • 2023
  • Polyacrylic rubber (ACM) is well known for its excellent heat resistance and chemical stability. Additionally, its performance can be readily manipulated by modifying its functional groups, rendering it highly attractive to various industries. However, extreme climate changes have necessitated an expansion of the operating temperature range and lifespan of ACM products. This requires the optimization of both the compounding process and functional-group design. Hence, we investigated the relationship between the cross-linking system and mechanical properties of an ACM with a carboxylic cure site. The crosslink density is determined by chemical kinetics according to the structure of additives, such as diamine crosslinkers and guanidine accelerators. This interaction enables the manipulation of the scotch time and mechanical properties of the compound. This fundamental study on the correlation analysis between cross-linking systems, physical properties, and storage stability can provide a foundation for material research aimed at satisfying the increasingly demanding service conditions of rubber products.

Synthesis of Vinyl-nano Silica Ball Composite : Its Application to Clearcoat (비닐-나노실리카볼 화합물의 클리어코트 특성 연구)

  • Kim, Bong-Gyeom;Park, Gun-Hee;Lee, Yong-Hwa;Noh, Seung-Man;Lee, Jae-Woo;Park, Seung-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.670-675
    • /
    • 2010
  • Inorganic-organic hybrid material such as vinyl-nano sized silica ball was synthesized by acrylo-alkoxysilane and nano silica ball with different particle size. And then they were formulated into acrylic-melamine clearcoat. This material is fully characterized with various analytical methods and applied for strength measurement. The glossy effect, matting effect and anti-scratching properties of materials were investigated for further growth and maintenance. When the particle size of nano silica ball is 20~30 nm, the glossy retain effect was increased by 7% compared to bare acrylic-melamine clearcoat. When a commercially available silica Aerosil 200 (Hydrophilic fumed silica, average particle size 12 nm, Degussa) react with vinyl alkoxysilane vinyl-fumed silica complex form. The vinyl-fumed silica along with clearcoat increases only 2% increase at glossy retain. Nano-scratch test results also support the glossy retain effect of vinyl nano-sized silica ball in clearcoat.

Radiation induced synthesis of (gelatin-co-PVA)-g-poly (AAc) copolymer as wound dressing material

  • Kaur, Inderjeet;Bhati, Pooja;Sharma, Sushma
    • Advances in materials Research
    • /
    • v.3 no.4
    • /
    • pp.183-197
    • /
    • 2014
  • Copolymers of gelatin and poly (vinyl alcohol), (PVA) grafted by acrylic acid (AAc) with excellent water absorption and retention abilities under neutral conditions were successfully synthesized using $^{60}Co$ gamma radiations in presence of ammonium persulphate (APS), as water soluble initiator and sodium bicarbonate ($NaHCO_3$) as foaming agent. The optimum synthesis conditions pertaining to maximum swelling percentage were evaluated as a function of gelatin/PVA ratio, amount of water, concentration of APS, $NaHCO_3$, monomer concentration and total irradiation dose. Maximum percent swelling (1694.59%) of the copolymer, gelatin-co-PVA, was obtained at optimum $[APS]=2.92{\times}10^{-1}mol/L$, $[NaHCO_3]=7.94{\times}10^{-2}mol/L$ and 1.5 mL of water at total dose of 31.104 kGy while in case of grafted copolymer, (gelatin-co-PVA)-g-poly(AAc), maximum percent swelling (560.86%) was obtained using $8.014{\times}10^{-1}mol/L$ of AAc in 9 mL water with 31.104 kGy preirradiation dose. The pristine and grafted copolymers were characterized by Fourier Transform Infrared Spectroscopy (FTIR), Scanning electron Microscopy (SEM), Thermal gravimetric analysis (TGA) and X-Ray Diffraction (XRD) methods. The copolymers loaded with an antiseptic, Povidone, were used as wound dressing materials for wounded gastrocnemius muscle of mice and the results exhibit that (gelatin-co-PVA)-g-poly (AAc) copolymer is a potent wound dressing material as compared to the copolymer.

A Study on the Synthesis of Acrylic Phenol Resins and Their Properties as a Paint (아크릴계 페놀수지 합성과 이를 이용한 도료의 물성연구)

  • Hwang, Sue In;Kim, Young Jin;Kim, Dong Kwon
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.171-176
    • /
    • 2013
  • The need of volatile organic compound (VOC) free coating material has been increased to solve environmental problems such as the global warming. Nowadays, about 70~80% of coating materials used in the worldwide are a liquid type. Therefore, the development of non-solvent coating material that can minimize VOCs emissions is necessary to solve the global warming problem. In this study, acrylic monomers were added to develop non-solvent paints in order to improve disadvantages of the poor adhesion of a conventional phenolic resin caused by acidification. As a result, the blend resins of 2.818 Mpa phenol- formaldehyde resin/poly methyl methacrylate (PE/PMMA) has the best properties and performances for the adhesives.

In vitro comparison of two different materials for the repair of urethan dimethacrylate denture bases

  • Cilingir, Altug;Bilhan, Hakan;Geckili, Onur;Sulun, Tonguc;Bozdag, Ergun;Sunbuloglu, Emin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.396-401
    • /
    • 2013
  • PURPOSE. The purpose of this in vitro study was to investigate the flexural properties of a recently introduced urethane dimethacrylate denture base material (Eclipse) after being repaired with two different materials. MATERIALS AND METHODS. Two repair groups and a control group consisting of 10 specimens each were generated. The ES group was repaired with auto-polymerizing polymer. The EE group was repaired with the Eclipse. The E group was left intact as a control group. A 3-point bending test device which was set to travel at a crosshead speed of 5 mm/min was used. Specimens were loaded until fracture occurred and the mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations were calculated for each group and the data were statistically analyzed. The results were assessed at a significance level of P<.05. RESULTS. The mean "displacement", "maximum load before fracture", flexural strength" and "flexural modulus" rates of Group E were statistically significant higher than those of Groups ES and EE, but no significant difference (P>.05) was found between the mean values of Group ES and EE. There was a statistically significant positive relation (P<.01) between the displacement and maximum load of Group ES (99.5%), Group EE (94.3%) and Group E (84.4%). CONCLUSION. The more economic and commonly used self-curing acrylic resin can be recommended as an alternative repair material for Eclipse denture bases.

Change of Ink Absorption Characteristics of Ink-Jet Printing Paper with Polymeric Binder (바인더용 고분자 첨가제에 따른 잉크젯 인화지의 잉크흡수 특성변화)

  • Kim, Chul-Yong;Lee, Myung-Cheon
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.550-555
    • /
    • 2006
  • The coating material for the ink-jet printing paper tends to be waterbase as the waterbase ink-jet ink is used more widely. Waterbase coating material consists of alumina sol as a pigment, poly(vinyl alcohol) as a main binder and polymeric additive for improving properties. In this study, polymeric auditive was synthesized by combining one or toto monomers among methacrylic acid, acrylic acid and acrylamide to the basic monomers, styrene and n-butylacrylate. The properties of printability such as ink absorption, ink spreading, and optical density, glossiness and water resistance were investigated by changing the kinds of surfactants, the composition of monomers and the structure of polymer particles. Results showed that materials containing anionic surfactant and/or acrylic acid had problems in com-patibility with alumina sol. Also, coating materials containing acrylamide had good printability and lout glossiness while those containing methacrylic acid did not have good printability and high glossiness.

Printing Properties of Ag Paste with the Variation of Binder on the SiNx Coated Si Wafer (SiNx 층이 코팅된 Si Wafer에 바인더 종류에 따른 Ag 페이스트의 인쇄 특성)

  • Kang, Jea Won;Shin, Hyo Soon;Yeo, Dong Hun;Jeong, Dae Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.85-90
    • /
    • 2014
  • Ag paste has been used in the front electrode of the Si-solar cell. It is composed by Ag powder, glass frit, binder, solvent and dispersant. The role of the binder and the solvent is to make a flow and a printing property. However, it was not enough to report the printing properties with the variation of binder in the controled viscosity. In this study, we selected 3 kinds of typical binder which were used as binder for the paste in the industry, such as Ethyl cellulose, Hydroxypropyl cellulose and Acrylic. Ag pastes using these were prepared, controled viscosity and printed on the SiNx coated Si wafer. In the 'A paste' used Acrylic binder, printed hight was highest and 'H paste' used Hydroxypropyl cellulose binder was lowest. Because 'H paste' was high viscosity due to the molecular weight, the solvent was added in the paste to control the viscosity. Therefore, the content of solid was lower in 'H paste'. The relative pattern width which is related to the spreading of paste was the best in the case of 'H paste' and 'EH paste' at $30^{\circ}C$. It is thought that the optimization of the relative pattern width is possible for a paste by the controling shear thinning phenomenon. In the case of 'A paste', though printing hight was best, the pattern width was dependant on the temperature.

Usefulness of Brain Phantom Made by Fused Filament Fabrication Type 3D Printer (적층 제조형 방식의 3D 프린터로 제작한 뇌 팬텀의 유용성)

  • Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.453-460
    • /
    • 2020
  • The price of the Brain phantom (Hoffman 3D brain phantom) used in nuclear medicine is quite expensive, it is difficult to be purchased by a medical institution or an educational institution. Therefore, the purpose of present research is to produce a low-price 3D brain phantom and evaluate its usefulness by using a 3D printer capable of producing 3D structures. The New 3D brain phantom consisted of 36 slices 0.7 mm thick and 58 slices 1.5 mm thick. A 0.7 mm thick slice was placed between 1. 5 mm thick slices to produce a composite slice. ROI was set at the gray matter and white matter scanned with CT to measure and compare the HU, in order to verify the similarity between PLA which was used as the material for the New 3D brain phantom and acrylic which was used as the material for Hoffman 3D brain phantom. As a result of measuring the volume of each Phantom, the error rate was 3.2% and there was no difference in the signal intensity in five areas. However, there was a significant difference in the average values of HU which was measured at the gray and white matter to verify the similarity between PLA and acrylic. By reproducing the previous Hoffman 3D brain phantom with a 100 times less cost, I hope this research could contribute to be used as the fundamental data in the areas of 3D printer, nuclear medicine and molecular imaging and to increasing the distribution rate of 3D brain phantom.

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Research for Thickness Change of Denture Base in Flask when Injecting Valplast Flexible Partial Denture Resin (발플라스트 레진 주입 시 발생되는 의치상의 두께변화에 관한 연구)

  • Jang, Wan-Young;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.47-56
    • /
    • 2008
  • This is a research for thickness change of denture base according to the shape of sprue & investment position of denture base in flask when injecting polyamid base resin for flexible partial denture as a part of study for Valplast among the flexible partial denture with a nylon base. It has been introduced several kinds of flexible partial denture product with a nylon base, but Valplast is the most widely used product among them. Valplast has been the most generally used material today since developed in 1950s in the United States as a material for flexible partial denture. Valplast is much more aesthetic than general metal-acrylic partial denture due to its translucent pink color and biocompatibility in terms of material characteristic. It keeps its flexibility for a long time after production, imposes a less burden on the teeth used as abutment, and it can be easily insert and remove due to its particular suppleness. Moreover, it is felt like real teeth more than metal-acrylic partial denture when being put in and takes alveolar bone under good protection since it receives occlusal force equally under the denture base. The most outstanding feature of Valplast is flexibility. The extent of its flexibility is determined by width & thickness of denture base. Considering general working procedure of Valplast, it can be seen that the thickness of denture base formed out of wax is increasing by the pressure while injecting resin. This research is to decide and test on the thickness increasing of Valplast by injecting pressure and the hypothesis upon that and is to prepare the basis estimating the increasing extent of thickness of denture base on the basis of the test result. In this test, it is expected occlusal malposition & thickness increasing of denture base by injecting pressure according to 4 kinds of test data which are to select 3 types of sprue method settling the forefront position at which the test material of fixed standard can be invested and to position the test material at the rearmost part keeping the minimum distance to set sprue. For 4 kinds of injecting test by investment position & sprue type, 20 test materials, 5 for each test were produced and a pressure of 1,180Kg was given with automatic injector of air cylinder type. The results are as follows: 1. For the amount of thickness increasing of denture base by investment position, the thickness of front investment is less increasing than the one of rear investment. 2. For the amount of thickness increasing of denture base by sprue type, the thickness of straight decompression sprue type which can absorb the injecting pressure after injecting polyamide base resin is less increasing than the other sprue types.

  • PDF