• Title/Summary/Keyword: Acoustic transducer

Search Result 391, Processing Time 0.026 seconds

Development of Surface Acoustic Wave Biosensor Using Epitaxial Lift-Off(ELO) Technology (ELO 기술을 이용한 표면 탄성파 바이오 센서의 개발)

  • 김기범;정우석;권대규;김남균;홍철운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.447-449
    • /
    • 2004
  • The purpose of this study is measured surface acoustic wave(SAW) characteristics to confirm utilization possibility as SAW sensor using new Pb(Mg$_{1}$3/Nb$_{2}$3/) $O_3$-PbTiO$_3$ (PMN-PT) piezoelectric substrate. We have tried to see if the material can be practically available as a new surface acoustic wave (SAW) biosensor to detect protein. The experimental results clarified that the frequency filtering of the central frequency of the PMN-PT substrate is a superior result to that of the LiTaO$_3$ (LT) substrate, but the result was not completely satisfactory. We know there is a problem in the design of inter-digital transducer (IDT) pattern. The waves transferred through the input terminal forms SAW which is sure to be transferred to the direction of the output terminal and the backward direction of the input terminal. This reflected wave is reiterated with SAW, which is transferred to the output direction, and so the frequency filtering gives a not good result. The electromechanical coupling coefficient of the PMN-PT substrate is excellent, and we can use it as a SAW sensor, in the near future, provided that there will be a new IDT design to increase the frequency filtering.

  • PDF

Characteristics of ZnO thin film for surface acoustic filters (표면탄성파 필터를 위한 ZnO 박막의 특성)

  • Kim, Young-Jin;Park, Wuk-Dong;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.45-50
    • /
    • 1995
  • The excellent c-axis oriented zinc oxide thin films were prepared by the RF magnetron sputtering method on glass substrates. Optimum fabrication conditions of the ZnO films were such that RF power, substrate temperature, and gas pressure of mixture Ar(50%):$O_{2}$(50%) were 150 W, $200^{\circ}C$, and 5 mTorr, respectively. In these conditions, the deposition rate was $310\;{\AA}/min$, and the resistivity of the film was $1{\times}10^6\;{\Omega}{\cdot}cm$. The ZnO film also showed high c-axis orientation and crystalinity according to XRD pattern and SEM photograph. A fabricated interdigital transducer generated 1st mode surface acoustic wave at 46.6 MHz and 2nd mode surface acoustic wave at 52.5 MHz. At the 1st mode, the phase velocity of surface acoustic wave and the electromechanical coupling coefficient were 2795 m/sec and 0.031 %, respectivly. At the 2nd mode, they were 3149 m/sec and 0.019 %. respectivly.

  • PDF

Fully Non-Contact Assessment of Acoustic Nonlinearity According to Plastic Deformation in Al6061 Alloy (Al6061 합금의 소성변형에 따른 음향비선형 특성의 완전 비접촉식 평가)

  • Lee, Hyeon;Chung, Cheon;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.388-392
    • /
    • 2012
  • This study proposes a fully non-contact measurement method to assess acoustic nonlinearity of narrowband surface waves generated by a line-arrayed laser beam by using a laser-ultrasonic detector in the way of two-wave mixing (TWM) method. This method was applied to figure out a relationship between plastic deformation and nonlinearity characteristics of a plastically deformed aluminum specimens. The experimental results showed that the acoustic nonlinearity of the laser-generated surface wave increased proportionally to the level of tensile deformation. This tendency is in good agreement with the result of measurement by contact method with PZT-transducer.

Acoustic Characteristics Analysis of Cylindrical Array for the Directional and Omni-directional mode Using the Boundary Element Method (경계요소법을 이용한 원통형 배열센서의 지향성/무지향성 모드에 대한 음향특성해석)

  • Lee, Jung-Min;Seo, Hee-Seon;Cho, Yo-Han;Baek, Kwang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.922-927
    • /
    • 2009
  • The transducers used in active sonar on surface ships are packed in a specific geometry in the array drum in order to meet the requirements such as the source level, directional beam pattern, etc. This paper describes the acoustic characteristics of the cylindrical array which is based on a 64 vertical staves arrangement, each stave composed 5 independent transducers. Firstly, the single transducer on the rigid baffle in the water is analyzed with the Finite Element Method. From the result of the FE analysis nodal velocities on the radiation surface is calculated and used with the boundary conditions of the transducers mounted on the array drum. Then the acoustic pressure is calculated in the field points using the Boundary Element Method and the other acoustic informations, the source level, beam pattern, near field and far-field distance, were acquired.

Structural health monitoring using piezoceramic transducers as strain gauges and acoustic emission sensors simultaneously

  • Huo, Linsheng;Li, Xu;Chen, Dongdong;Li, Hongnan
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.595-603
    • /
    • 2017
  • Piezoceramic transducers have been widely used in the health monitoring of civil structures. However, in most cases, they are used as sensors either to measure strain or receive stress waves. This paper proposes a method of using piezoelectric transducers as strain gauges and acoustic emission (AE) sensors simultaneously. The signals received by piezoceramic transducers are decomposed into different frequency components for various analysis purposes. The low-frequency signals are used to measure strain, whereas the high-frequency signals are used as acoustic emission signal associated with local damage. The b-value theory is used to process the AE signal in piezoceramic transducers. The proposed method was applied in the bending failure experiments of two reinforced concrete beams to verify its feasibility. The results showed that the extracted low-frequency signals from the piezoceramic transducers had good agreement with that from the strain gauge, and the processed high-frequency signal from piezoceramic transducers as AE could indicate the local damage to concrete. The experimental results verified the feasibly of structural health monitoring using piezoceramic transducers as strain gauges and AE sensors simultaneously, which can advance their application in civil engineering.

In situ side-aspect target strength of Japanese anchovy (Engraulis japonicus) in northwestern Pacific Ocean (북서 태평양 멸치(Japanese anchovy)에 대한 측면 음향 반사강도 특성)

  • Lee, Hyung-Been;Kang, Don-Hyug
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.3
    • /
    • pp.248-256
    • /
    • 2010
  • Acoustic side-aspect target strength (TS) of living Japanese anchovy (Engraulis japonicus) was measured at 120kHz during in situ experiments. The data were collected by lowering and horizontally projecting the splitbeam transducer into the anchovy school. For analysis and interpretation of the side-aspect TS data, acoustic theoretical model, based on the fish morphology, and dorsal-aspect TS data were used. Total length of the anchovy ranged from 6.6 to 12.8cm (mean length 9.3cm). The side-aspect TS distributed between -40 and -55dB, has an obvious length dependency. The mean side-aspect TS of the anchovy was -47.8dB, and the TS was about 2dB higher than mean TS generated from dorsal-aspect measurements. With reference to maximum TS, the results of the side-aspect TS were distributed within the range of the theoretical and dorsal-aspect TS. Apparently these tendency indicates that side-aspect TS measured from the study is useful data. These in situ measurements of side-aspect TS can be applied to improve acoustic detection and estimates of the anchovy, and is necessary to measure with a various frequency and length for making enhance data.

Characteristics Evaluation of the Lens for Underwater Acoustic Imaging (수중음향 영상화를 위한 렌즈 제작 및 특성 평가)

  • Cho, Wan-Ho;Kwon, Hyu-Sang;Cho, Yo-Han;Seo, Hee-Seon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

The Characteristics and Spatio-temporal Distribution of Fish Schools during Summer in the Marine Ranching Area (MRA) of Yeosu using Acoustic Data (음향 자료를 이용한 하계 여수 바다목장 해역에서 어군의 시·공간 분포와 특징)

  • Yoon, Eun-A;Hwang, Doo-Jin;Kim, Ho-Sang;Lee, Kyung-Seon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.3
    • /
    • pp.283-291
    • /
    • 2014
  • This study assessed dominant fish species, and the characteristics and spatio-temporal distribution of fish schools using acoustic and catch data in the marine ranching area (MRA) of Yeosu in July and August 2013. Acoustic data were collected using a 200-kHz dual beam transducer, and catch data were analyzed through auction data generated by a set net installed in the MRA. More fish schools were detected by acoustic methods in July than in August. The temporal distribution of fish schools differed between July and August, but, many schools demonstrated a high mean volume scattering strength (SV) around artificial reefs. Additionally, the characteristics of fish schools detected by echograms and the species caught by set nets differed between July and August. The dominant fish species were Engraulis japonicus, Pampus argenteus, Scomberomorus niphonius, and Pampus echinogaster in July, and approximately 85% of the catch in August consisted of Scomberomorus niphonius. Therefore, hydro-acoustic tools are useful for estimating fish school characteristics in large areas over a short period. To determine species, it is important to conduct net sampling surveys during the acoustic surveys. However, if a database of fish school characteristics organized by species is constructed through continuous study, it could be possible to identify fish species through acoustic methods alone.

A Study on the Discrimination of Materials Corrosion States Using the Acoustic Signal Data (음향신호 데이터를 이용한 재료 부식 상태 판별에 관한 연구)

  • Moon, Gun
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.2
    • /
    • pp.131-139
    • /
    • 2005
  • On this study, I constructed the reflective acoustic signal detecting system using 15MHz acoustic transducer. The most difficult problems discriminating the characteristics of the metal substance are the discriminating the corrosion state and seeking hidden defects by using none destructive testing. For solving these problems, at first, theoretic analysis has been proceeded on the acoustic V(z) characteristics which is very important on discriminating the material characteristics. For application the V(z) theory to discriminating corrosion state, the 100 and 500 won metal coins which are issued on the different years are used as the test samples. The experimental results showed the distinct differences among the coin's acoustic signals accorded to its issued years. I catched the common regulation by analysing the acquisited acoustic signals and convinced this technique to be very useful on corrosion discrimination of the metal substances by none destructive testing and also can be used to inspect on the aeronautical materials for safety navigation.

  • PDF

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF