• Title/Summary/Keyword: Acoustic transducer

Search Result 391, Processing Time 0.026 seconds

On-demand Acoustofluidic Droplet Generation with Tunable Droplet Volume (음향미세유체역학적 미세액적 생성 및 부피 제어)

  • Kim, Woo Hyuk;Park, Jinsoo
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.46-50
    • /
    • 2020
  • On-demand droplet generation with tunable droplet volume is fundamental in many droplet microfluidic applications. In this work, we propose an acoustofluidic method to produce water-in-oil droplets with prescribed volume in an on-demand manner. Surface acoustic waves produced from a slanted interdigital transducer are coupled with parallel laminar streams of dispersed and continuous phase fluids. Acoustic radiation force acting on the fluid interface enable generation of droplets in a microfluidic chip. We expect that the proposed acoustofluidic droplet generation method will serve as a promising tool for on-demand droplet generation with on-chip droplet volume control.

Piezoelectric and Acoustic Properties of PZI-Polymer 1 -3-0 Type Composite (PZT-고분자 1-3-0형 복합압전체의 압전 및 음향특성)

  • 양윤석;유영준;최헌일;손무헌;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.317-320
    • /
    • 1999
  • In this study, the piezoelectric ceramics PZT powder was synthesized by Wet-Dry combination method. And the flexible 1-3-0 type composites were fabricated with piezoceramic PZT and Eccogel polymer matrix embedded 3rd phase. Dielectric constant of 1-3-0 type composites was lower than that of single phase PZT ceramics. Thickness mode coupling factor k/sub t/ which was comparable with single phase PZT ceramics and mechanical quality factor Qm were about 0.65 and 6, respectively. These composites are considered as a good candidates for broad-band type transducer applications. The acoustic impedance of 1-3-0 type composites was lower than that of single phase PZT ceramics. Therefore, these composites would be better used for hydrophone applications.

  • PDF

A Study on NDE technique using Acoustic Reflection Microscope (반사형 음향 현미경을 이용한 비파괴 검사 기술에 관한 연구)

  • Moon, Geon;Ko, Dae-Sik;Kim, Jang-Gwon;Jun, Gye-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.23-30
    • /
    • 1987
  • In this paper, the characteristic response of reflected signals of acoustic reflection microscope, V(z) phenomenon, has been studied and a new type of NDE technique has been presented. 10 Won coin, aluminium, IC component, and kevlar-epoxy samples have been used for the experiment of NDE and the acoustic microscope operating at a center frequency of 3 MHz has been used in the focused or defocused mode of operation. In experiment, it has been shown that the acoustic microscope has the resolution of $500\mu m$ and the defects present on the surface and near surface of samples have been detected by acoustic transducer and imaged on a monitor, and the variation of the contrast of image for samples has been in good agreement with V(z) phenomenon.

  • PDF

Analysis of Acoustic Emission Signals from Fluid Leakage (유체 누출에서의 음향방출 신호분석)

  • 김용민;윤용구;김호철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.413-421
    • /
    • 1990
  • Acoustic emission signals due to leak from circular holes of 0.4, 1, 2 and 4mm diameter and rectangular slits of different geometry having the same cross section as 4mm diameter hole was studied both analytically and experimentally. Acoustic emission signals from a wide-band type transducer were transformed to digital signals through a digital oscilloscope, and $V_{rms}$ and frequency spectrum were obtained by processing digital signals. Relationships between acoustic parameters and fluid mechanical parameters were derived analytically. A quadrapole aerodynamic model was applied in the analysis of leak from the circular holes and $V_{rms}$ was found to be proportional to the root square of leak rate through the circular hole. A modified model based on dipole source mechanism and laminar equivalent diameter was applied in the analysis of leak signals from the rectangular slits. In the case of constant pressure, $V_{rms}$ increased as the laminar equivalent diameter of slit decreased. In the case of constant laminar equivalent diameter, however the result was similar to that for leak from the circular hole. The frequency spectra of leak signals shows the same frequency characteristics irrespective of the pressure difference.rence.

Cell-cultivable ultrasonic transducer integrated on glass-coverslip (세포 배양 가능한 커버슬립형 초음파 변환자)

  • Keunhyung Lee;Jinhyoung Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.412-421
    • /
    • 2023
  • Ultrasound brain stimulation is spot-lighted by its capability of inducing brain cell activation in a localized deep brain region and ultimately treating impaired brain function while the efficiency and directivity of neural modulation are highly dependent on types of stimulus waveforms. Therefore, to optimize the types of stimulation parameters, we propose a cell-cultivable ultrasonic transducer having a series stack of a spin-coated polymer piezoelectric element (Poly-vinylidene fluoride-trifluorethylene, PVDF-TrFE) and a parylene insulating layer enhancing output acoustic pressure on a glass-coverslip which is commonly used in culturing cells. Due to the uniformity and high accuracy of stimulus waveform, tens of neuronal cell responses located on the transducer surface can be recorded simultaneously with fluorescence microscopy. By averaging the cell response traces from tens of cells, small changes to the low intensity ultrasound stimulations can be identified. In addition, the reduction of stimulus distortions made by standing wave generated from reflections between the transducers and other strong reflectors can be achieved by placing acoustic absorbers. Through the proposed ultrasound transducer, we could successfully observe the calcium responses induced by low-intensity ultrasound stimulation of 6 MHz, 0.2 MPa in astrocytes cultured on the transducer surface.

Design and Piezoelectric properties of 2-2 piezocomposite Ultrasonic Transducers by means of the Finite Element Methode (유한요소해석법을 이용한 2-2형 압전복합재료 초음파 트랜스듀서의 설계 및 압전특성)

  • Park, Jae-Sung;Lee, Sang-Wook
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.40-46
    • /
    • 2011
  • In this study, PZT-5A green sheet were prepared by using tape casting technique, and the piezoelectric properties of PZT-5A by variation of sintering temperature was investigated. After, design and piezoelectric properties of 2-2 piezocomposite ultrasonic transducers by menas of the FEA. The acoustic impedance and piezoelectric charge constant of the 2-2 type piezocomposite transducer decreased proportionally due to the density decrease caused by the PZT volume fraction decrease. The piezocomposite acoustic impedance were 7~3 MRayl between 0.6 and 0.2 allowing it to be used for a ultrasonic transducer. The resonance characteristics and the electro-mechanical coupling factor were the best when the volume fraction PZT was 0.6. The PZT volume fraction shows the fixed value, 0.6~0.65, approximately within the range between 0.2 and 0.6 while it is increased to decreased over the range. The result of the experiment above confirmed that the 2-2 piezoelectric composites could be used as the ultrasonic transducers.

Acoustic radiation characteristics of a tile projector with performance variations among unit transducers (단위 트랜스듀서 간 성능편차를 갖는 타일형 프로젝터의 음향방사 특성)

  • Chun, Wonjong;Noh, Eunghwy;Ohm, Won-Suk;Seo, Youngsoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.436-444
    • /
    • 2016
  • Uniformity in transducer performance is a must-have to ensure the reliable acoustic performance of a tile projector, used for active echo reduction. However, practical limitations imposed by variations in material properties and fabrication errors lead to performance variations among unit transducers, which could degrade the radiation characteristics (transmitting voltage response and directivity) of the tile projector and ultimately the echo reduction performance. In this paper we present a method to minimize these adverse effects via an appropriate placement of unit transducers within the tile projector. To this end, we perform a series of coupled acoustic-piezoelectric simulations, assuming a group of 36 unit transducers having 6 dB variations in transmitting voltage response, to analyze and compare the radiation characteristics of tile projectors under different transducer placement schemes.

Thermal Sensitivity of the Bean Curd by Ultrasonic Irradiation (초음파 조사에 의한 두부의 열 감도)

  • 조문재;윤용현;부유천;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.503-513
    • /
    • 2004
  • In this paper, the thermal sensitivity, i .e. the temperature rise per unit acoustic power, was newly defined and proposed as a performance parameter of a tissue mimicking material. Eatable tofu (bean curd) manufactured by a factory was selected as a sample material for the experiment. The temperature changes were measured not only with the variation of ultrasonic irradiation time, acoustic power, depth from the sample surface. and the distance from the source transducer while adjusting the frequency to 8 MHz but also with the variation of frequency while acoustic power. depth from the sample surface. and the distance from the source transducer keeping constant. As a result of a consideration for the transformation of the measured temperature changes to thermal sensitivities. the thermal sensitivity was found to be sufficient to use as a Performance parameter for tissue mimicking material. The tofu as a tissue mimicking material showed the maximum thermal sensitivity at 10 MHz, as is a significant result to imply the possibility that the thermal sensitivity of real human tissue strong1y depends on the frequency.

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.

Parametric Array Sonar System Based on Maximum Likelihood Detection (최대우도 검파에 기반한 파라메트릭 어레이 소나 시스템)

  • Han, Jeong-Hee;Lee, Chong-Hyun;Paeng, Dong-Guk;Bae, Jin-Ho;Kim, Won-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In the underwater communications, transmitted acoustic signal is corrupted by interference from multipath. A parametric array transducer is capable of radiating a narrow beam with very low sidelobe levels. In certain cases, the parametric array transducer can help the multipath problem. To improve the performance of the underwater communications, the statistical signal processing methods will be required. In the paper, the communication system using a parametric array transducer was demonstrated. To detect the received signal of the communication system based on the on-off keying, the maximum likelihood method using averaged signal for a particular window size is used. The communication system has GUI using LebVIEW which allows the user to change the parameter. The GUI can also be easily modified based on the characteristics of a parametric array transducer. The implemented system can effectively evaluate the performance of the parametric array transducer.