• Title/Summary/Keyword: Acoustic signal

Search Result 1,391, Processing Time 0.03 seconds

Double Talk Processing using Blind Signal Separation in Acoustic Echo Canceller (음향반향제거기에서 암묵신호분리를 이용한 동시통화처리)

  • Lee, Haengwoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • This paper is on an acoustic echo canceller solving the double-talk problem by using the blind signal separation technology. The acoustic echo canceller may be deteriorated or diverged during the double-talk period. So we use the blind signal separation to detect the double talking by separating the near-end speech signal from the mixed microphone signal. The blind signal separation extracts the near-end signal from dual microphones by the iterative computations using the 2nd order statistical character in the closed reverberation environment. By this method, the acoustic echo canceller operates irrespective of the double-talking. We verified performances of the proposed acoustic echo canceller in the computer simulations. The results show that the acoustic echo canceller with this algorithm detects the double-talk periods well, and then operates stably without diverging of the coefficients after ending the double-talking. The merits are in the simplicity and stability.

An Investigation of Acoustic Signal Characteristics in Turning of Aluminum (알루미늄 선삭공정에서 발생되는 음향 신호 특성)

  • Lee, Chang-Hee;Kim, Yong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.457-462
    • /
    • 2007
  • This paper reports on the research which investigates acoustic signals acquired in turning with rough and finish simultaneously. The material is aluminum thin pipe. Two acoustic sensors were set on CNC machine. One was set on the finish bite and the other the rough. Two signals were first analyzed in order to consider how much the acoustic signal from the finish bite was coupled by that from the rough. A simple data collecting system to acquire signals from the finish was then determined because two acoustic signals were little coupled. Second the fundamental experiments were accomplished to study the effects of machine vibration and material state. The signal characteristics due to surface defects were studied from the collected acoustic signal data. The signal analysis was based on real time data, root mean squared average and frequency spectrum by fast fourier transform. As a result, the acoustic signals were made effects by machine condition, material structure. The acoustic signal from the finish bite was closely correlated with surface quality. Two types surface micro defects were then evaluated by the signal characteristics.

  • PDF

Post Processing using Blind Signal Separation in Stereo Acoustic Echo Canceller (스테레오 음향반향제거기의 BSS 후처리방법)

  • Lee, Haeng Woo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.1
    • /
    • pp.131-138
    • /
    • 2014
  • This paper is on a stereo acoustic echo canceller with the blind signal separation for post processing. The convergence speed of the stereo acoustic echo canceller is deteriorated due to mixing two residual signals which are update signals of each echo canceller. To solve this problem, we are to use the blind signal separation(BSS) method separating the mixed signals after the echo cancellers. The blind signal separation method can extracts the source signals by means of the iterative computations with two input signals. We had verified performances of the proposed acoustic echo canceller for stereo through simulations. The results of simulations show that the acoustic echo canceller for stereo using this algorithm operates stably without divergence in the normal state. And, when the speech signals were inputted, this echo canceller achieved about 2dB higher ERLE with the BSS post processing method than without this method. This stereo echo canceller showed the best performance in the case of inputting the real voice signal.

An Acoustic Echo Canceller for Stereo Using Blind Signal Separation (암묵신호분리를 이용한 스테레오 음향반향제거기)

  • Lee, Haeng Woo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.3
    • /
    • pp.125-131
    • /
    • 2012
  • This paper is on a stereo acoustic echo canceller with the blind signal separation. The convergence speed of the stereo acoustic echo canceller is deteriorated due to mixing two residual signals in the update signal of each echo canceller. To solve this problem, we are to use the blind signal separation(BSS) method separating the mixed signals. The blind signal separation method can extracts the source signals by means of the iterative computations with two input signals. We had verified performances of the proposed acoustic echo canceller for stereo through simulations. The results of simulations show that the acoustic echo canceller for stereo using this algorithm operates stably without divergence in the normal state. And, when the speech signals were inputted, this echo canceller achieved about 3dB higher ERLE in the case of using the BSS algorithm than the case of not using the BSS algorithm. But this echo canceller didn't get good performances in the case of inputting the white noises as stereo signals.

A Study on the Spectrum Analyzing of Internal Leak in Valve for Power Plant Using Acoustic Emission Method (음향방출법에 의한 발전용 밸브내부 누설의 스펙트럼분석 연구)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Jun-Shin;Sohn, Seok-Man
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.694-699
    • /
    • 2004
  • The purpose of this study is to estimate the availability of acoustic emission method to the internal leak of the valves at nuclear power plants. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. From the comparison of the background noise data with the experimental results as to relation between leak flow and acoustic signal, the minimum leak flow rates that can be detected by acoustic signal was suggested. When the background levels are higher than the acoustic signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given.

  • PDF

A Study on the Frequency Analyzing of Leak Evaluation m Valve for Power Plant Using AE (AE법에 의한 발전용 밸브누설평가를 위한 주파수분석 연구)

  • LEE SANG-GUK
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.360-364
    • /
    • 2004
  • The objective of this study is to estimate the feasibility of acoustic emission method Jar the internal leak from the valves in nuclear power plants. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. From the comparison of background noise data with the experimental results as to relation between leak flow and acoustic signal, the minimum leak flow rates that am be detected by acoustic signal was suggested. When the background noise level are higher than the acoustic signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum.

  • PDF

An Investigation of Acoustic Signal Characteristics in Turning of Aluminum (알루미늄 선삭공정에서 발생되는 음향 신호 특성)

  • Kim, Yong-Yun;Lee, Chang-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.507-514
    • /
    • 2007
  • This paper reports on the research which investigates acoustic signals acquired in turning with rough and finish simultaneously. The material is aluminum thin pipe. Two acousto-ultrasonic sensors were set on the finish and the rough bite of the CNC machine. It was first evaluated that one source was affected by the other. It was found that two signals were little affected each other, and that the acoustic signal from the finish bite was more related to the surface defects. Signals from the finish bite only were then analyzed in order to observe several types of surface defects. Second the fundamental experiments were accomplished to study the effects of machine vibration and material state. The signal characteristics due to surface defects were studied from the collected acoustic signals. The analysis was based on real time data, root mean squared average and frequency spectrum by fast fourier transform. As a result, the acoustic signals were made effects by machine condition, material structure. The acoustic signal from the finish bite was closely correlated with surface quality. Two types surface micro defects were then evaluated by the signal characteristics.

An Acoustic Echo Canceller for Double-talk by Blind Signal Separation (암묵신호분리를 이용한 동시통화 음향반향제거기)

  • Lee, Haeng-Woo;Yun, Hyun-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.2
    • /
    • pp.237-245
    • /
    • 2012
  • This paper describes an acoustic echo canceller with double-talk by the blind signal separation. The acoustic echo canceller is deteriorated or diverged in the double-talk period. So we use the blind signal separation to estimate the near-end speech signal and to eliminate the estimated signal from the residual signal. The blind signal separation extracts the near-end signal with dual microphones by the iterative computations using the 2nd order statistical character. Because the mixture model of blind signal separation is multi-channel in the closed reverberation environment, we used the copied coefficients of echo canceller without computing the separation coefficients. By this method, the acoustic echo canceller operates irrespective of double-talking. We verified performances of the proposed acoustic echo canceller by simulations. The results show that the acoustic echo canceller with this algorithm detects the double-talk periods thoroughly, and then operates stably in the normal state without the divergence of coefficients after ending the double-talking. And it shows the ERLE of averagely 20dB higher than the normal LMS algorithm.

Robust Energy Efficiency Power Allocation for Uplink OFDM-Based Cognitive Radio Networks

  • Zuo, Jiakuo;Dao, Van Phuong;Bao, Yongqiang;Fang, Shiliang;Zhao, Li;Zou, Cairong
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.506-509
    • /
    • 2014
  • This paper studies the energy efficiency power allocation for cognitive radio networks based on uplink orthogonal frequency-division multiplexing. The power allocation problem is intended to minimize the maximum energy efficiency measured by "Joule per bit" metric, under total power constraint and robust aggregate mutual interference power constraint. However, the above problem is non-convex. To make it solvable, an equivalent convex optimization problem is derived that can be solved by general fractional programming. Then, a robust energy efficiency power allocation scheme is presented. Simulation results corroborate the effectiveness of the proposed methods.

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.