• Title/Summary/Keyword: Acoustic response

Search Result 574, Processing Time 0.031 seconds

Bandwidth Enhancement of Underwater Acoustic Transducer Using a Bandpass Matching Network (대역통과 정합회로를 이용한 수중음향변환기의 대역폭 확장)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.702-708
    • /
    • 2019
  • The range resolution of echo sounders can be improved by enhancing the transducer bandwidth. We designed a bandpass matching network for expanding the bandwidth of a transducer by scaling in both impedance and frequency after transforming a lowpass network into a bandpass configuration for a third-order Bessel filter. We measured the effect of the Bessel matching network for a 50 kHz sandwich type transducer on the transmitting voltage response (TVR), receiving sensitivity (SRT) and figure of merit (FOM), using a chirp echo sounder system. Both the simulation and experimental results indicated that the transducer with a bandpass matching network was capable of producing a symmetrical acoustic output over a wider bandwidth (8.25 kHz) than was the transducer without a matching network (3.75 kHz). By implementing the Bessel matching network, we achieved a 120% bandwidth enhancement.

Reduction of Flow-Induced Vibration in the Heat Exchanger (열교환기에서의 유동유발 진동 저감)

  • 장한기;김승한;이재현;양정렬
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1200-1209
    • /
    • 1999
  • This paper reports a peculiar example of flow-induced vibration in a very large plant and the whole procedure of reducing the vibration. During the operation of flue gas desurfurization unit of the thermal power plant, serious vibration was dtected at all around the plant. The worst vibration was recorded on the heat exchanger surface, which weighed 180 tones, as 17.8 m/$s^2$ in vibration amplitude at 34 Hz. To identify the vibration, frequency analysis on the response vibration as well as on the expected excitation forces and the system resonance was executed. This investigation revealed that the cause of the vibration was vortex shedding from the circular pipes in the heat exchanger. Vortices from the pipes excited acoustic resonance in the heat exchanger room, which, in turn, made the structure vibrate. Through inserting the baffles between the pipes, which had an effect of cutting the acoustic wave at resonance frequency, the vibration was eliminated dramatically.

  • PDF

Design of an Acoustic band Interpolator for Underwater Sensor Nodes (수중 센서 노드를 위한 음파 대역 인터폴레이터 설계)

  • Kim, Sunhee
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.1
    • /
    • pp.93-98
    • /
    • 2020
  • Research on underwater sensor networks is increasing due to such reasons as marine resource management, maritime disaster prediction and military protection. Many underwater sensor networks performs wireless communication using an acoustic sound wave band signal having a relatively low frequency. So the digital part of their modem can take charge of carrier band signal processing. To enable this, the sampling rate of the baseband band signal should be increased to a sampling rate at which carrier band signal processing is possible. In this paper, we designed a sampling rate increasing circuit based on a CIC interpolator for underwater sensor nodes. The CIC interpolator has a simple circuit structure. However, since the CIC interpolator has a large attenuation of the pass band and a wide transition band, an inverse sinc LPF is added to compensate for frequency response of the CIC interpolator. The proposed interpolator was verified in time domain and frequency domain using ModelSim and Matlab.

Sound Radiation from Vibrating Bridges subjuct to Moving Vehicles (주행차량에 의한 교량의 동적거동과 음향방사특성)

  • 김상효;이용선;장원석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.45-51
    • /
    • 2002
  • An acoustic finite element model of a bridge is developed to evaluate the noise generated by the traffic-induced vibration of the bridge. The dynamic response of a multi-girder bridge, modeled by a 3-dimensional frame element model, is analyzed with a 3-axle 8 DOFs truck model and a 5-axle 13 DOFs semi-trailer. The flat plate element is used to analyze the acoustic pressure due to the fluid-structure interactions between the vibrating surface and contiguous acoustic fluid medium. The radiation fields of noise with a specified distribution of vibrating velocity and pressure on the structural surface are also computed using the Kirchhoff-Helmholtz integral. Although the noise produced by the bridge vibration is not serious in itself, which is below the audible frequency range, it should be considered as an interaction problem between vehicle noise and bridge vibration noise in order to evaluate the traffic noise around the bridge.

  • PDF

Advantages of Acoustic Leak Detection System Development for KALIMER Steam Generators

  • Kim, Tae-Joon;Valery S. Yughay;Hwang, Sung-Tai;Chai, Jeong-Kyung;Choi, Jong-Hyeun
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.423-440
    • /
    • 2001
  • For sodium cooling liquid metal reactors during the last 25 years, it was most important to verify the safety of the steam generator, which absolutely requires a water leak detection system with fine sensitivity and response. This study describes the structure and leak classification of the HAMMER (Korea Advanced Liquid Metal Reactor) steam generator, compared with other classifications, and explains the effects of leak development. The requirements and experimental situations for the development of the KALIMER acoustic leak detection system (KADS) which detects micro leaks, not intermediate leaks, are introduced. We proposed four frequency bands, 1∼8kHz, 8∼20kHz, 20∼40kHz and 40∼200kHz, split effectively for analyzing the detected acoustic leak signals obtained from the sodium-water reaction model or water model in the mock-up system.

  • PDF

A comparative study of full-band and sub-band approaches to acoustic echo cancellation (음향 피드백 제거를 위한 전대역, 협대역 적응 필터의 비교)

  • 신민철;김상명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.645-651
    • /
    • 2003
  • The system in which a microphone and a loudspeaker are simultaneously used can cause an echo. The echo is caused by feedback between the output of the loudspeaker and the input of the microphone. The acoustic echo canceller is a device to cancel the echo in a communication system. Its general procedure for cancellation is first estimating the plant response of the feedback path and then eliminating the feedback signal from the input signal. In this paper, full-band and sub-band approaches are compared by using some simulation examples.

  • PDF

Surface Acoustic Waves Sensors for Wireless Measurement of Temperature (Surface Acoustic Wave를 이용한 무선 온도 센서 설계 및 구현)

  • Kim, Jaek-Won;Park, Joo-Yong;Kim, Kyung-Hwan;Yeo, Joon-Ho;Burm, Jin-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.469-470
    • /
    • 2006
  • Surface Acoustic Wave(SAW) devices can be used to as wireless sensor elements, called SAW transponders, for measuring shysical quantities such as temperature that do not need any power supply and may be accessed wirelessly. SAW devices were fabricated on Y-Z $LiNbO_3$ piezoelectric substrate with a good temperature coefficient property. The signal response of SAW sensor on the temperature change were compared. To measure the change of SAW velocity. Temperature changed form $20^{\circ}C$ to $400^{\circ}C$ was linearly changed, the SAW sensor is application to the temperature sensor.

  • PDF

Effects of Electrical and Acoustical Variations for Loudspeaker due to Fabrication Processes (조립과정이 스피커의 전기 및 음향특성에 미치는 영향)

  • Park, Seok-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.155-159
    • /
    • 2004
  • In this paper, it was analyzed the characteristics of electrical and acoustical variations for loudspeaker due to fabrication processes. First, mass of each components of loudspeaker was measured by electric precision scale and performed statistical analysis. Second. Thiele-Small parameters of sample loudspeakers produced by unskilled students were identified by known mass parameter identification method using electrical impedance method and investigated on the variations of each parameter. Electrical impedance tests and acoustic frequency responses were measured on sample loudspeakers and variations were examined to grasp relationship between components variation and fabrication processes. Main factors to effect the changes of electrical impedance were concluded by fabrication processes errors not by components of loudspeaker.

  • PDF

Wind-induced dynamic response of recessed balcony facades

  • Matthew J. Glanville;John D. Holmes
    • Wind and Structures
    • /
    • v.38 no.3
    • /
    • pp.193-202
    • /
    • 2024
  • Modern high-rise tower designs incorporating recessed balcony cavity spaces can be prone to high-frequency and narrow-band Rossiter aerodynamic excitations under glancing incident winds that can harmonize and compete with recessed balcony volume acoustic Helmholtz modes and facade elastic responses. Resulting resonant inertial wind loading to balcony facades responding to these excitations is additive to the peak design wind pressures currently allowed for in wind codes and can present as excessive facade vibrations and sub-audible throbbing in the serviceability range of wind speeds. This paper presents a methodology to determine Cavity Amplification Factors to account for façade resonant inertial wind loads resulting from balcony cavity aero-acoustic-elastic resonances by drawing upon field observations and the results of full-scale monitoring and model-scale wind tunnel tests. Recessed balcony cavities with single orifice type openings and located within curved façade tower geometries appear particularly prone. A Cavity Amplification Factor of 1.8 is calculated in one example representing almost a doubling of local façade design wind pressures. Balcony façade and tower design recommendations to mitigate wind induced aero-acoustic-elastic resonances are provided.

First Trial of the State of the Art Acoustic Systems Mounted on the R/V Tamgu 21 (수산자원전용조사선 탐구 21호에 탑재된 최첨단 음향장비 소개와 첫 시험조사)

  • Hwang, Kangseok;Lee, Jeong-hoon;Park, Jeong-Ho;Cha, Hyung Kee;Choi, Jung Hwa;Lee, Hyungbeen;Park, Junseong;Kang, Myounghee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.4
    • /
    • pp.509-515
    • /
    • 2016
  • At the first time in South Korea, the state of the art acoustic systems were mounted on the R/V Tamgu 21. The acoustic systems are an EK80 broadband echosounder (18, 38, 70, 120, 200 and 333 kHz) which has two beam modes such as continuous wave (narrowband) and frequency modulation (broadband), an ME70 multibeam echosounder (70-120 kHz), and a SH90 sonar (111.5-115.5 kHz). Acoustic data from broadband mode have a very short range resolution, a large detection range, a high signal to noise ratio, and a wide and consecutive frequency response. In ME70, each individual beam consisted in a multibeam plays a role as a spilt beam. The first trial of the cutting edge acoustic system installed on the R/V Tamgu 21 was conducted from 15 Feb to 29 Feb 2016 in East Sea, South Sea and East China Sea. The properties of the acoustic systems were elucidated and exploratory results from three systems were exhibited. Lastly, issues which should be considered and future research plan are mentioned.